background image

● OPERATING INSTRUCTIONS ●

ENGLISH IS ORIGINAL

EN-1

S

AFETY PRECAUTIONS

C

ONTENTS

 SAFETY PRECAUTIONS 

1

 NAME OF EACH PART 

4

 PREPARATION BEFORE OPERATION 

5

 SELECTING OPERATION MODES 

6

 FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

7

 I-SAVE OPERATION  

8

 ECONO COOL OPERATION  

8

 TIMER OPERATION (ON/OFF TIMER) 

8

 NIGHT MODE OPERATION  

9

 WEEKLY TIMER OPERATION 

10

 

DEMAND RESPONSE AND INDOOR UNIT OPERATION 

11

 EMERGENCY OPERATION 

11

 AUTO RESTART FUNCTION  

11

 CLEANING 12

 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

13

 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

14

 INSTALLATION PLACE AND ELECTRICAL WORK 

14

 SPECIFICATIONS 14

 WARNING

Do not connect the power cord to an intermediate point, use an 

extension cord, or connect multiple devices to a single AC outlet.

•  This may cause overheating, fi re, or electric shock.

Make sure the power plug is free of dirt and insert it securely 

into the outlet.

•  A dirty plug may cause fi re or electric shock.

Do not bundle, pull, damage, or modify the power cord, and do 

not apply heat or place heavy objects on it.

•  This may cause fi re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the power 

plug during operation.

•  This may create sparks, which can cause fi re.

•  After the indoor unit is switched OFF with the remote controller, 

make sure to turn the breaker OFF or disconnect the power plug. 

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

•  Be sure to receive a guarantee card from your dealer and check that the 

purchased date and shop name, etc. are entered correctly.

Marks and their meanings

 WARNING :

Incorrect  handling  could  cause  serious  hazard,  such  as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 

on the conditions.

Meanings of symbols used in this manual

 :  Be sure not to do.
 :  Be sure to follow the instruction.
 :  Never insert your fi nger or stick, etc.

 : 

Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.
 :  Be sure to disconnect the power supply plug from the power outlet.
 :  Be sure to shut off  the power.

 :  Risk of fi re.

Meanings of symbols displayed on indoor unit and/or outdoor unit

WARNING

(Risk of fi re)

This unit uses a fl ammable refrigerant.

If refrigerant leaks and comes in contact with fi re or heating part, it will create harmful gas and there is risk of fi re.

Read the OPERATING INSTRUCTIONS carefully before operation.

Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.

Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like.

Do not expose your body directly to cool air for a prolonged 

length of time.

•  This could be detrimental to your health.

The unit should not be installed, relocated, disassembled, 

altered, or repaired by the user.

•  An  improperly  handled  air  conditioner  may  cause  fi re,  electric 

shock, injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced by the 

manufacturer or its service agent in order to avoid a hazard.

When installing, relocating, or servicing the unit, make sure that 

no substance other than the specifi ed refrigerant (R32) enters 

the refrigerant circuit.

•  Any presence of foreign substance such as air can cause abnormal 

pressure rise and may result in explosion or injury.

• 

The use of any refrigerant other than that specifi ed for the system will 

cause mechanical failure, system malfunction, or unit breakdown. In 

the worst case, this could lead to a serious impediment to securing 

product safety.

JG79Y725H01_01En.indd   1

2020/03/09   10:23:25

Содержание MSZ-AP15VGD

Страница 1: ...TIONERS INDOOR UNIT MSZ AP15VGD MSZ AP20VGD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use JG79Y725H01_cover indd 1 2020 02 20 14 24 10 ...

Страница 2: ...RNING Incorrect handling could cause serious hazard such as death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Meanings of symbols used in this manual Be sure not to do Be sure to follow the instruction Never insert your finger or stick etc Never step onto the indoor outdoor unit and do not put anything on them Danger o...

Страница 3: ...t This may cause injury if you fall down Do not pull the power cord This may cause a portion of the core wire to break which may cause overheating or fire Do not charge or disassemble the batteries and do not throw them into a fire This may cause the batteries to leak or cause a fire or explosion Do not operate the unit for more than 4 hours at high humidity 80 RH or more and or with windows or outsi...

Страница 4: ...it may cause an explosion Earth the unit correctly Do not connect the earth wire to a gas pipe water pipe lightning rod or a telephone earth wire Improper earthing may cause electric shock CAUTION Install an earth leakage breaker depending on the installation location of the air conditioner such as highly humid areas If an earth leakage breaker is not installed it may cause electric shock Ensure t...

Страница 5: ...ge 7 8 TIME TIMER set buttons Page 5 8 forward button backward button CLOCK button Page 5 RESET button Page 5 Lid Slide the lid down to open the remote controller Slide it down further to get to the weekly timer buttons i save button Page 8 TIME WEEKLY TIMER set buttons Page 5 10 Air inlet Air inlet back and side Refrigerant piping Drainage hose Air outlet Drain outlet Remote controller holder Ins...

Страница 6: ...teries with ex pired shelf lives last shorter Press RESET gently using a thin instrument If the RESET button is not pressed the remote controller may not operate correctly Note Press CLOCK gently using a thin instrument Note How to set remote controller exclusively for a particular indoor unit A maximum of 4 indoor units with wireless remote controllers can be used in a room To operate the indoor ...

Страница 7: ... operation Lit Blinking Not lit The unit selects the operation mode according to the difference between the room temperature and the set temperature During AUTO mode the unit changes mode COOL HEAT when the room temperature is about 2 C away from the set temperature for more than 15 minutes Note Auto Mode is not recommended if this indoor unit is connected to a MXZ type outdoor unit When several in...

Страница 8: ...true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 13 To change the horizontal airflow direction Move the vertical vane manually before starting operation Note If the vertical vanes are adjusted while the unit is not operating be sure to return the horizontal vanes to the original closed position Press to select fan speed Each press changes...

Страница 9: ...tting for COOL ECONO COOL and HEAT This ena bles you to select your preferred setting with a single push of the button ECONO COOL OPERATION Swing airflow change of air flow makes you feel cooler than stationary airflow The set temperature and the airflow direction are automatically changed by the microprocessor It is possible to perform cooling operation with keeping comfort As a result energy can be ...

Страница 10: ...t change after start up of the unit dur ing the protection operation or depending on other operating conditions The fan speed of the indoor unit will not change The operation indicator lamp will be hard to be seen in a bright room Operating POWERFUL operation during NIGHT MODE operation will increase the noise level of the outdoor unit Noise level of the outdoor unit will not decrease during Multi...

Страница 11: ...y timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note Wh...

Страница 12: ...sponse represents the automated alteration of an electrical product s normal mode of operation in response to an initiating signal originating from or defined by a remote agent This unit supports 3 Demand Response Modes DRMs DRM Description of operation in this mode Operation indicator lamp Lit Not lit DRM 1 Compressor off The air conditioner does not perform cooling or heating opera tion during the...

Страница 13: ...e with water After washing with water dry it well in shade Important Clean the filters regularly for best performance and to reduce power consumption Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold It is therefore recommended to clean air filters every 2 weeks Front panel 1 Lift the front panel until a click is heard 2 Hold the hinges ...

Страница 14: ... outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 5 Is the polarity of the batteries correct Page 5 Are any buttons on the remote controller of other electric applia...

Страница 15: ...ours Page 6 This dries the inside of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 12 2 Check that the air inlet and outlet of the indoor and outdoor unit...

Страница 16: ...HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79Y725H01 JG79Y725H01_cover indd 2 2020 02 20 14 24 10 ...

Отзывы: