En-3
(G)
(E)
(C)
(4)
(D)
(F)
(5)
(3)
(2)
(1)
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Installation plate
1
(2)
Installation plate fixing screw 4 × 25 mm
5
(3) Wireless remote controller
1
(4)
Felt tape (For left or left-rear piping)
1
(5) Battery (AAA) for (3)
2
PARTS TO BE PROVIDED AT YOUR SITE
(A) Indoor/outdoor unit connecting wire*
1
(B) Extension pipe
1
(C) Wall hole sleeve
1
(D) Wall hole cover
1
(E)
Pipe fixing band
2 to 5
(F)
Fixing screw for (E) 4 × 20 mm
2 to 5
(G) Piping tape
1
(H) Putty
1
(I)
Drain hose
(or soft PVC hose, 15 mm inner diameter or hard PVC pipe
VP16)
1 or 2
(J) Refrigeration oil
1
* Note:
Place indoor/outdoor unit connecting wire (A) at least 1 m
away from the TV antenna wire.
108 mm
or more
81 mm
or more
66 mm or more/
142 mm or more for
left and left back pip
-
ing (using spacer)
13 mm or more
1-4. INSTALLATION DIAGRAM
Units should be installed by licensed contractor according
to local code requirements.
Before installation
This installation manual is only for the indoor unit installation. In installing
the outdoor units, refer to the installation manual attached to each outdoor
unit. Any structural alternations necessary for the installation must comply
with the local building code requirements.
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and make the
fan stop.
The outdoor unit produces condensate during the heating operation. Select
the installation place to ensure to prevent the outdoor unit and/or the
grounds from being wet by drain water or damaged by frozen drain water.
1.8 m to 2.3 m from the
floor is recommended
IMPORTANT NOTES
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
When the piping is to be attached to a wall containing metals (tin plated) or metal
netting, use a chemically treated wooden piece 20 mm or thicker between the
wall and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping.
To use existing piping, perform COOL operation for 30 minutes and pump
down before removing the old air conditioner. Remake flare according to the
dimension for new refrigerant.
After the leak test, apply insulating material tightly
so that there is no gap.
WARNING
To avoid risk of fire, embed or protect the refrigerant piping.
External damage on the refrigerant piping can be cause of fire.
Be sure to use wall hole sleeve (C)
to prevent indoor/outdoor connect
-
ing wire (A) from contacting metal
parts in the wall and to prevent
damage by rodents in case the
wall is hollow.
Indoor unit
Wall hole
sleeve (C)
Cut off the
extra length.
Pipe fixing band (E)
Wall hole cover (D)
Fixing screw (F)
Seal the wall hole
gap with putty (H).
Fix the pipe to wall
with pipe fixing band
(E).
JG79J074H01_en.indd 3
2017/09/27 9:46:39