Installation place
Avoid installing the air conditioner in the following
places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as hot spring,
sewage, waste water.
• Where oil is splashed or where the area is fi lled with
oily smoke (such as cooking areas and factories, in
which the properties of plastic could be changed and
damaged).
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit
bothers the house next door.
• The mounting height of indoor unit 1.8 m to 2.3 m is
recommended. If it is impossible, please consult your
dealer.
• The indoor unit must be installed in rooms which
exceed the fl oor space specifi ed. Please consult your
dealer.
• Do not operate the air conditioner during interior
construction and fi nishing work, or while waxing the
fl oor. Before operating the air conditioner, ventilate the
room well after such work is performed. Otherwise, it
may cause volatile elements to adhere inside the air
conditioner, resulting in water leakage or scattering of
dew.
Electrical work
• Provide an exclusive circuit for the power supply of the
air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
To prevent the
effects of a
fl uorescent lamp,
keep as far apart
as possible.
wall,
etc.
Keep a
space to
prevent
the picture
distortion or
the noise.
1 m
or more
Radio
100 mm or
more
TV
Cordless
phone or
Portable
phone
3 m or more
1 m
or more
The installation location of the outdoor unit should be
at least 3 m away from the antennas for TV sets, ra-
dios, etc. In areas where the reception is weak, provide
greater space between the outdoor unit and the antenna
of the affected device if operation of the air conditioner
interferes with radio or TV reception.
For the optimum
effi ciency and to
extend the life
time of using, the
outdoor unit should
be installed in a
well-ventilated dry
place.
200 mm
or more
Inverter-type
fl uorescent lamp
Guaranteed operating range
S
PECIFICATIONS
Indoor
Outdoor
Cooling
Upper limit
32°C DB
23°C WB
46°C DB
—
Lower limit
21°C DB
15°C WB
21°C DB
—
Heating
Upper limit
27°C DB
—
24°C DB
18°C WB
Lower limit
20°C DB
—
0°C DB
—
DB: Dry Bulb
WB: Wet Bulb
I
NSTALLATION PLACE AND ELECTRICAL WORK
Note:
As for the specifi cations of multi system,
please confi rm your dealer and/or refer to
the catalogue.
A5_JG79Y754H01_01En.indd 22
2020/06/02 10:07:05
Содержание MSY-GS07VF
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ...A5_white_tombo indd 1 2019 10 08 15 46 41 ...
Страница 47: ...A5_white_tombo indd 1 2019 10 08 15 46 41 ...