Mitsubishi Electric MSY-GJ10VA Скачать руководство пользователя страница 2

En-1

● OPERATING INSTRUCTIONS ●

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

Marks and their meanings

 WARNING :

Incorrect  handling  could  cause  serious  hazard,  such  as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 

on the conditions.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

 :  Never insert your fi nger or stick, etc.

 :  Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.

 :  Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

S

AFETY PRECAUTIONS

C

ONTENTS

 SAFETY PRECAUTIONS 

1

 NAME OF EACH PART 

3

 PREPARATION BEFORE OPERATION 

3

 SELECTING OPERATION MODES 

4

 FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

5

 ECONO COOL OPERATION  

5

 TIMER OPERATION (ON/OFF TIMER) 

5

 CLEANING 

6

 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

7

 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

8

 INSTALLATION PLACE AND ELECTRICAL WORK 

8

 SPECIFICATIONS 

8

 WARNING

Do not connect the power cord to an intermediate point, 

use an extension cord, or connect multiple devices to a 

single AC outlet.

•  This may cause overheating, fi re, or electric shock.

Make sure the power plug is free of dirt and insert it se-

curely into the outlet.

•  A dirty plug may cause fi re or electric shock.

Do not bundle, pull, damage, or modify the power cord, and 

do not apply heat or place heavy objects on it.

•  This may cause fi re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the 

power plug during operation.

•  This may create sparks, which can cause fi re.

•  After the indoor unit is switched OFF with the remote con-

troller, make sure to turn the breaker OFF or disconnect the 

power plug. 

Do not expose your body directly to cool air for a prolonged 

length of time.

•  This could be detrimental to your health.

The unit should not be installed, relocated, disassembled, 

altered, or repaired by the user.

•  An improperly handled air conditioner may cause fi re, electric 

shock, injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced by the 

manufacturer or its service agent in order to avoid a hazard.

When  installing,  relocating,  or  servicing  the  unit,  make 

sure that no substance other than the specifi ed refrigerant 

(R410A) enters the refrigerant circuit.

•  Any presence of foreign substance such as air can cause ab-

normal pressure rise and may result in explosion or injury.

•  The use of any refrigerant other than that specifi ed for the 

system will cause mechanical failure, system malfunction, 

or unit breakdown. In the worst case, this could lead to a 

serious impediment to securing product safety.

This appliance is not intended for use by persons (includ-

ing  children)  with  reduced  physical,  sensory  or  mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concern-

ing use of the appliance by a person responsible for their 

safety.
Children should be supervised to ensure that they do not 

play with the appliance.

  

Do not insert your fi nger, a stick, or other objects into the 

air inlet or outlet.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

  

In case of an abnormal condition (such as a burning smell), 

stop the air conditioner and disconnect the power plug or 

turn the breaker OFF.

•  A continued operation in the abnormal state may cause a 

malfunction, fi re, or electric shock. In this case, consult your 

dealer.

When the air conditioner does not cool or heat, there is 

a possibility of refrigerant leakage. In this case, consult 

your dealer. If a repair involves recharging the unit with 

refrigerant, ask the service technician for details.

•  The refrigerant used in the air conditioner is safe. Normally, 

it does not leak. However, if refrigerant leaks and comes in 

contact with a heat source such as a fan heater, kerosene 

heater, or cooking stove, it will create a harmful gas.

The user should never attempt to wash the inside of the 

indoor unit. Should the inside of the unit require cleaning, 

contact your dealer.

•  Unsuitable detergent may cause damage to plastic material 

inside the unit, which may result in water leakage. Should 

detergent come in contact with electrical parts or the motor, 

it will result in a malfunction, smoke, or fi re.

JG79A732H01_en.indd   1

2013/01/18 (金)   午前 10:13:09

Содержание MSY-GJ10VA

Страница 1: ...SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSY GJ10VA MSY GJ13VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ... relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refr...

Страница 3: ... unit for more than 4 hours at high hu midity 80 RH or more and or with windows or outside door left open This may cause the water condensation in the air conditioner which may drip down wetting or damaging the furniture The water condensation in the air conditioner may contribute to growth of fungi such as mold Do not use the unit for special purposes such as storing food raising animals growing ...

Страница 4: ...ection ON OFF operate stop button Temperature buttons Page 4 Operation select button Page 4 ECONO COOL button Page 5 FAN speed control button Page 5 Off timer button Page 5 On timer button Page 5 VANE control button Page 5 TIME set buttons Pages 3 5 Increase time Decrease time CLOCK button Page 3 RESET button Page 3 Lid Slide down to open Install the remote control ler holder in a place where the ...

Страница 5: ...mperature About 1 to 2 C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode i...

Страница 6: ...nge the horizontal airflow direction Move the vertical vane manually before starting operation Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the airflow Set temperature is set 2 C higher au tomatically Press again to cancel ECONO COOL operation Pressing also cancels ECONO COOL operation What ...

Страница 7: ...d viruses This air filter has a semi permanent lasting effect even after washing it with water Pull to remove from the air filter Air filter Nano platinum filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water After washing with water dry it well in shade CLEANING Switch off the power supply or turn off the breaker before cleaning Be careful not to touch the metal parts with yo...

Страница 8: ...rations pipe or pipe connecting sections are cooled and this causes water to condense Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed D...

Страница 9: ...ent lamp Keep a space to prevent the pic ture distortion or the noise 1 m or more Radio 100 mm or more Well ventilated dry place 100 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor un...

Страница 10: ... dibaiki oleh pengguna Penyaman udara yang tidak dikendalikan dengan betul boleh menyebabkan kebakaran kejutan elektrik kecederaan atau kebocoran air dll Sila berunding dengan wakil penjual anda Jika kord kuasa rosak ia mesti diganti oleh pengilang atau ejen servisnya bagi mengelakkan bahaya Semasa memasang memindahkan atau menservis unit ini pastikan tiada bahan lain selain daripada bahan penyeju...

Страница 11: ...n anda cuci dengan teliti menggunakan air yang bersih Jika cecair bateri terkena mata anda cuci dengan teliti menggunakan air yang bersih dan dapatkan rawatan perubatan dengan segera Pastikan kawasan itu mempunyai sistem pengudaraan yang baik apabila unit ini dikendalikan bersama dengan perkakas pembakaran Pengudaraan yang tidak mencukupi boleh menyebabkan kekurangan oksigen MATIKAN pemutus apabil...

Страница 12: ...pan 4 Tekan RESET Salur udara belakang dan tepi Perpaipan bahan penyejuk Perpaipan Salur keluar udara Salur keluar saliran Unit luaran Unit luaran anda mungkin berbeza rupanya Bahagian paparan Lampu penunjuk operasi Bahagian penerima isyarat kawalan jauh Suis operasi kecemasan Halaman 4 Ram melintang Ram menegak Salur keluar udara Kipas Penapis udara Penapis platinum nano Saluran masuk udara Penuk...

Страница 13: ...kan atau bagi menetapkan suhu Setiap kali anda menekannya suhu akan naik atau turun sebanyak 1 C Tekan untuk menghentikan operasi Tetapan yang sama akan dipilih pada kali seterusnya dengan hanya menekan Fungsi mula semula auto Jika bekalan kuasa terputus atau kuasa utama dimatikan semasa operasi Auto restart function fungsi mula semula auto akan memulakan operasi secara automatik dalam mod yang sa...

Страница 14: ...i pemasa Jika bekalan kuasa terputus semasa pemasa ON OFF ditetapkan lihat halaman 4 Fungsi mula semula auto OPERASI PEMASA PEMASA ON OFF Tekan untuk memilih kelajuan kipas Setiap kali anda menekannya kelajuan kipas akan bertukar dalam urutan berikut Bunyi bip pendek akan kedengaran dua kali dari unit dalaman apabila ditetapkan kepada AUTO Tekan untuk memilih arah aliran udara Setiap kali anda men...

Страница 15: ... memasangnya 3 Pasang panel depan dengan mengikuti cara menanggalkannya tetapi dalam urutan songsang Tutup panel depan dengan baik dan tekan kedudukannya seperti yang ditunjukkan oleh anak panah Pandu Penapis pembersih udara Penapis Enzim Anti alahan Bahagian belakang penapis udara Setiap 3 bulan Buang kotoran dengan pembersih hampagas Apabila kotoran tidak boleh dibuang dengan pembersih hampagas ...

Страница 16: ...tau bahagian penyambungan paip disejukkan dan ini menyebabkan berlakunya pemeluwapan Alat kawalan jauh Paparan pada alat kawalan jauh tidak muncul atau malap Unit dalaman tidak bertindak balas terhadap isyarat alat kawalan jauh Adakah bateri sudah lemah Halaman 3 Adakah kekutuban bateri betul Halaman 3 Adakah sebarang butang pada alat kawalan jauh bagi perkakas elektrik lain sedang ditekan Tidak m...

Страница 17: ...mm atau lebih Tempat yang kering dengan pengudaraan yang baik 100 mm atau lebih TV Telefon tanpa wayar atau telefon boleh alih 3 m atau lebih 1 m atau lebih Lokasi pemasangan unit luaran hendaklah sekurang kurangnya 3 m dari antena set TV radio dll Di kawasan di mana penerimaan lemah tingkatkan jarak antara unit luaran dan antena bagi peranti yang terjejas jika operasi penyaman udara mengganggu pe...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A732H01 ...

Отзывы: