18
18
MSH-GD80VB
Part name
Figure
Check method and criterion
Indoor fan motor (MF)
INNER
PROTECTOR
135 ± 5 OPEN
Color of
lead wire
WHT – BLK
BLK – RED
Room temperature
thermistor (RT11)
Indoor coil thermistor
(RT12 (main), RT13 (sub))
Horizontal vane
motor (MV1)
Vertical vane
motor (MV2)
Motor part
Sensor part
Measure the resistance between the terminals with a tester.
(Part temperature 10°C ~ 30°C)
Color of lead wire
BRN – YLW
YLW – GRY
Normal
4.5 ~ 5.5 V
Measure the voltage power ON.
(When fan revolved one time)
0 V 5 V 0 V
(Approx.)
Normal
282
Ω
~ 306
Ω
Measure the resistance between the terminal with a tester.
(Part temperature 10°C ~ 30°C)
BLK
RED
WHT
GR
Y
YL
W
BRN
132
Ω
~ 144
Ω
152
Ω
~ 166
Ω
Normal
Measure the resistance with a tester.
(Part temperature 10°C ~ 30°C)
Refer to 10-6."Test point diagram and voltage",
"Indoor electronic control P.C. board", for the chart of thermistor.
YLW
GRN
ORN
BRN
RED
ROTOR
MAIN
AUX.
P
: INNER PROTECTOR
P
10-4. TROUBLE CRITERION OF MAIN PARTS
OBH513A