45
SPECIFICATIONS
The noise value is tested in the condition of laboratory
(
No background noise
).
Test standard
:
GB
/
T7725 GB4706
·
32
-
2004 GB4343
·
1
-
2003
2
3
Note
:
Guaranteed operating range
:
1
Cooling
Upper Limit
lower Limit
Indoor
Outdoor
32
℃
DB
,
23
℃
DB
21
℃
DB
,
15
℃
DB
43
℃
DB
,-
21
℃
DB
,-
MSD-CF09VB-H1
2800
890
4.2
553
750
40/26
45
10
27
Electric-shock proof protection
Power supply
Cooling capacity(W)
Rated power input(W)
Rated current(A)
Air flow volume(m
3
/h)
Refrigerant charging(g)
Noise (indoor unit(dB(A))(Hi/Lo)
Noise (outdoor unit(dB(A))
Net weight (indoor unit)(kg)
Net weight (outdoor unit)(kg)
Dimensions H W D (indoor unit)(mm)
Dimensions H W D (outdoor unit)(mm)
Connect pipe length (m)
Highest work pressure of discharge(MPa)
Highest work pressure of suction(MPa)
Maximum work pressure of heat exchange(MPa)
Limit pressure of accumulator(MPa)
MSD-CF12VB-H1
3650
1160
5.5
548
1080
40/29
46
10
37
model
I type
220V
~
50Hz
278 815 238
550 800 285
4
4.15
1.64
4.71
1.94
46