![Mitsubishi Electric MSD-CF09VB-H1 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/mitsubishi-electric/msd-cf09vb-h1/msd-cf09vb-h1_operating-instructions-manual_1810436031.webp)
30
When the batteries of the remote controller run out or
remote controller malfunctions.Emergency operation
can be done using the Emergency operation switch.
Batteries
Notes for using the remote controller
WHEN THE REMOTE CONTROLLER CANNOT
BE USED(Emergency operation)
Laying the remote controller
●
●
Laying places
The places where it is easy to operate and easily visible.
The places where children can not touch.
In rooms where inverter type fluorescent lamps are
used,the signal from the wireless remote controller not
be received.
NOTE
Details of operation are as shown below.
However,the temperature control does not work
for about 30minutes at first and the unit is set to
the continuous operation mode with the fan speed
set to "Medium",30 minutes late:
Details of opration
Set temperation
Fan speed
Horizontal vane
Cool
24
℃
Medium
Auto
The operation mode is indicated by
the room temperature on the indoor
unit as following figures.
Press the Emergency operation switch.
●
●
●
●
The range that the signal can reach is about 6m when
pointed at the front of the indoor unit.
When the button is pressed,one or two beeps will be heard
from the indoor unit.If no sound is heard,operate again.
Use the remote controller carefully.
If it is dropped,thrown or gets wet,it may not operate.
Do not wring or press the remote controller,it may cause
the componets inside the remote controller damage.
●
●
●
●
Replace 2 batteries with new batteries of the same type.
Do not use rechargeable batteries.
To prevent from liquid leakage,take out all batteries when
the remote controller is not going to be used for a long
time.
The service life of an alkaline battery is about 1 year.
However,since the recommended usable time limit is
indicated(month/year)on the bottom of the battery,a
battery the time limit of which is approaching may become
exhaust sooner.
When the signal does not operate the indoor unit,or the
display becomes dim.replace the batteries with new alkaline
batteries(LR03)
Reference for replacing batteries
Each time the switch is pressed,the unit
alternates between the Emergency COOL
mode and STOP mode.
To stop the Emergency operation,press the
Emergency operation switch.
Each time the switch is pressed,the unit alternates
between the Emergency COOL mode and STOP
mode.
PREPARATION BEFORE OPERATION
1
EMERGENCY COOL
STOP
℃
℃
Indicating
TEMP
POWER
Operation Indicator
lamp not lighted
POWER
Room TEMP and Operation
Indicator lamp not lighted
TEMP