background image

6

ON/OFF

FAN

TOO

WARM

TOO

COOL

VANE

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

I FEEL COOL

DRY

AM

PM

CLOCK

˚

C

AMPM

HEAT
/FAN

RESET CLOCK

I FEEL... AUTO OPERATION

With the “

 (I FEEL...)” auto operation mode, the optimum room condition can be set automatically

with a one-touch operation.

To start operation:

Press the 

ON/OFF

 button.

When the 

 (I FEEL...)

 mode is selected, the air conditioner is automatically

controlled at the optimum temperature.

To stop operation:

Press the 

ON/OFF

 button.

If you feel slightly warm:

Press the 

TOO

WARM

 button to lower the temperature.

One press lowers the temperature by about 1

°

C.

If you feel slightly cool:

Press the 

TOO

COOL

 button to raise the temperature.

One press raises the temperature by about 1

°

C.

When

  (I  FEEL...)

  is  not  selected,  press  the 

MODE

button until it is set.

Each time the button is pressed, the operation mode is changed
in sequence: 

 (I FEEL...) 

 (COOL) 

 (DRY) 

(HEAT/FAN)

Description of “AUTO RESTART FUNCTION”

These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start
operation automatically in the same mode as the one set with the remote controller before the shutoff of the main
power.

If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.

If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power
comes on, in the same mode as the one set with the remote controller before the emergency operation.

If the unit is operated in 

I FEEL...

  mode before power failure, the operation mode (COOL, DRY or HEAT) is not

stored in the memory. When the main power is turned on, the unit decides the operation mode by the initial room
temperature at restart and starts operation again.

ON/OFF

FAN

TOO

WARM

TOO

COOL

VANE

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

I FEEL COOL

DRY

AM

PM

CLOCK

˚

C

AMPM

HEAT
/FAN

RESET CLOCK

Details of operation

According to the room temperature when the operation starts, the operation mode is automatically set to COOL, DRY or
HEAT. However, when operation is started again within 2 hours after it  is stopped, the same operation mode before the
operation is stopped is selected. The operation mode selected first is not changed even if the room temperature changes.
If the operation mode does not match the room condition, select the appropriate operation mode by pressing the 

MODE

button.

Details of auto operation

Operation state

This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature
is obtained.

This  shows  that  the  room  temperature  is  approaching  the
target temperature.

(In case of outdoor unit MX Z  series only)
Please refer to Information for multi system air conditioner.
(Page 7 )

Indication

Difference between target

temperature and room temperature

About 2

°

C or more

About 2

°

C or less

Description of “I FEEL...” mode

COOL & HEAT type

COOL ONLY type

Room temperature

Operation mode

Target temperature

Operation mode

Target temperature

when started

 (initial state)

 (initial state)

About 25

°

C or higher

COOL

About 24

°

C

COOL

About 24

°

C

About 25

°

C - 23

°

C

DRY

DRY

About 23

°

C or lower

HEAT

About 26

°

C

DRY

NOTE:
COOL: When the room temperature is 2° C higher than the set temperature, the set temperature may not be

changed since the air conditioner is operating to reach the target (set) temperature. In this case, please
wait  until  the  room  temperature  drops  to  within  2° C  of  the  set  temperature  and  then  change  the  set
temperature.

HEAT:

When  the  room  temperature  is  2° C  lower  than  the  set  temperature,  the  set  temperature  may  not  be
changed since the air conditioner is operating to reach the target (set) temperature. In this case, please
wait  until  the  room  temperature  rises  to  within  2° C  of  the  set  temperature  and  then  change  the  set
temperature.

Details of display on the indoor unit

The operation indicator at the right side of the indoor unit indicates the operation state.

Operation indicator lamp

Lighted

B linking

Not lighted

Operation Indicator

Содержание MSC-GA20VB

Страница 1: ...men te e p er in tero Ο ΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ È ÙÔÓ ÂÏ ÙË È Ó Ú ËÛ ÈÌ Ô ÔÈ Û ÂÙ ٠ÙËÓ Ì ÔÓ Û ˆ Û Ù Î È Ì Â Û Ê ÏÂÈ Â Èˆ ı  Ù fi ÙÈ ÂÙÂ È Û ÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁ ÈÒ Ó Ú ÈÓ fi ÙËÓ Ú Û Ë INSTRU Ç Õ ES DE OPERAÇ Ã O P a ra os clien tes P a ra utiliz a r esta un id a d e correcta men te certifiq ue se d e q ue lê esta s in struç õ es d e op era ç ã o a n tes d a utiliz a ç ã o B RU G SANV ISNING T il...

Страница 2: ... r injury fro m the unit falling w ater leak ing etc C o nsult yo ur d ealer If the p o w er sup p ly co rd is d amag ed it must b e rep laced b y the manufacturer o r its serv ice ag ent in o rd er to av o id a haz ard D o n o t in s e rt y o u r fin g e r o r a s tic k e tc in to th e a ir in le t o u tle t S ince the fan ro tates at hig h sp eed this may cause an injury Y o ung child ren sho ul...

Страница 3: ...NS NAME OF EACH PART Indoor unit Outdoor unit Operation Indicator lamp Remote control receiving section Piping Drainage hose Air outlet Drain outlet Air cleaning filter White bellows type OPTION Vertical vane Operation section When the front panel is opened Front panel Air inlet to Breaker Power supply cord Remote control receiving section Display section Air outlet Horizontal vane Remote controll...

Страница 4: ... n tro lle r th e o p e ra tio n m o d e th e s e t te m p e ra tu re a n d th e fa n s p e e d a re s to re d in th e m e m o ry If a p o w e r fa ilu re o c c u rs o r th e m a in p o w e r is tu rn e d o ff d u rin g o p e ra tio n A u to re s ta rt fu n c tio n s e ts a u to m a tic a lly to s ta rt o p e ra tin g in th e s a m e m o d e a s th e o n e s e t w ith th e re m o te c o n tro lle ...

Страница 5: ...MODE and STOP MODE However when the EMERGENCY OPERATION switch is once pressed the unit will operate in test run for 30 minutes and then the operation mode shifts to EMERGENCY MODE Details of EMERGENCY MODE are as shown below However the temperature control does not work for 30 minutes in test run and the unit is set to continuous operation The fan speed is set to High in test run and shifts to Me...

Страница 6: ...CK Details of operation According to the room temperature when the operation starts the operation mode is automatically set to COOL DRY or HEAT However when operation is started again within 2 hours after it is stopped the same operation mode before the operation is stopped is selected The operation mode selected first is not changed even if the room temperature changes If the operation mode does ...

Страница 7: ... the operation while the defrosting of outdoor unit is being done it takes a few minutes max 10 minutes to blow out the warm air In the heating operation the indoor unit that does not operate may get warm or the sound of refrigerant flowing may be heard This is not a malfunction since the refrigerant continuously flows into the indoor unit that does not operate Description of AUTO RESTART FUNCTION...

Страница 8: ...rs while AUTO START STOP timer is active the timer setting is cancelled As these models are equipped with an auto restart function the air conditioner starts operating with timer cancelled at the same time that power is restored What is ECONO COOL Swing air flow change of air flow makes you feel cooler than constant air flow So even though the set temperature is automatically set 2 C higher it is ...

Страница 9: ...ilter is dyed with a natural material catechin that is contained in tea The catechin air filter deodorizes odor and noxious gases such as formaldehyde ammonia and acetaldehyde Moreover it restraints the activity of the viruses adhering to the filter Air cleaning filter Remove the catechin air filter Remove the air cleaning filter White bellows type Install a new air cleaning filter Install the cat...

Страница 10: ... FUNCTION on page 6 Q uestion The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor unit Air does not blow out soon in the heating operation The operation is stopped for about 10 minutes in the heating operation Hissing sound is some times he...

Страница 11: ... C DB 19 C WB Outdoor 35 C DB Heating Indoor 20 C DB Outdoor 7 C DB 6 C WB 2 Guaranteed operating range Indoor Outdoor Upper limit 32 C DB 43 C DB Cooling 23 C WB Lower limit 21 C DB 21 C DB 15 C WB Upper limit 27 C DB 24 C DB Heating 18 C WB Lower limit 20 C DB 10 C DB 11 C WB To prevent the effects of a fluorescent lamp keep as far apart as possible wall etc Inverter type fluorescent lamp Keep a...

Страница 12: ...in c u i s i v e rific h i u n p ro b le m a o u n a n o m a lia S im b o li p re c a u z io n a li e d i lo ro s ig n ific a ti A V V E R T E N Z A L u s o s c o rre tto p u ò fa c ilm e n te c a u s a re le s io n i g ra v i o m o rte C A U T E L A L u s o s c o rre tto p u ò c a u s a re le s io n i g ra v i in d e te rm in a te c irc o s ta n z e S ig n ific a ti d e i s im b o li u s a ti in ...

Страница 13: ...NORME DI SICUREZZA CAUTELA Per l installazione AVVERTENZA Per l installazione consultare il proprio rivenditore o contraente Trattandosi di operazioni particolarmente tecniche I installazione non deve essere effettuata dal cliente Se l installazione non viene effettuata correttamente potrebbe causare incendio shock elettrico danni o fuoriuscita di acqua Non installare il climatizzatore in luoghi d...

Страница 14: ... v e lo c ità d e lla v e n to la s o n o m a n te n u ti in m e m o ria S e s i v e rific a u n in te rru z io n e d i c o rre n te o s e s i s p e g n e l a lim e n ta z io n e p rin c ip a le d u ra n te il fu n z io n a m e n to q u e s ta fu n z io n e ria v v ia a u to m a tic a m e n te l a p p a re c c h io c o m e e ra s ta to im p o s ta to c o n il te le c o m a n d o im m e d ia ta m e...

Страница 15: ...ti e quindi passerà in MODO EMERGENZA La seguente tabella mostra i dettagli del MODO EMERGENZA Tuttavia il controllo della tempera tura non funziona per i primi 30 minuti in modo funzionamento di prova e l unità è impostata nel modo di funzionamento continuo La velocità della ventola è impostata su Alta du rante il funzionamento di prova e passa su Media dopo 30 minuti Modo funzionamento Raffredda...

Страница 16: ...ONE RISCALDAMEN TO VENTILAZIONE Tipo RAFFREDDAMENTO e RISCALDAMENTO Tipo SOLO RAFFREDDAMENTO Temperatura Modo di Temperatura obiettivo Modo di Temperatura obiettivo ambiente iniziale funzionamento condizione iniziale funzionamento condizione iniziale Circa 25 C o più RAFFREDDAMENTO Circa 24 C RAFFREDDAMENTO Circa 24 C Circa 25 C 23 C DEU MIDIFICAZIONE DEU MIDIFICAZIONE Circa 23 C o meno RISCALDAME...

Страница 17: ...amento a pagina 56 In questo caso si prega di impostare tutte le unità interne nella stessa modalità di funzionamento Quando la unità interna inizia a funzionare una volta completata la fase di sbrinamento della unità esterna ci vorranno alcuni minuti max 10 minuti prima che venga soffiata aria calda Nella modalità di riscaldamento la unità interna che non sta funzionando può riscaldarsi oppure si...

Страница 18: ...are che il filo di messa a terra sia collegato correttamente CAUTELA Mettere a terra il climatizzatore Non collegare il filo di messa a terra con una tubazione dell acqua del gas un parafulmine o un filo del telefono Se la messa a terra non è buona si possono verificare folgorazioni MANUTENZIONE Prima di iniziare la manutenzione Disattivare l interruttore di circuito e o scolle gare la spina d ali...

Страница 19: ...con un materiale naturale contenuto nel tè la catechina Il filtro dell aria alla catechina deodora e combatte i gas nocivi quali la formaldeide l ammoniaca e l acetaldeide Inoltre limita l attività dei virus che aderiscono al filtro PULIZIA DEL FILTRO DELL ARIA ALLA CATECH INA Pulizia del filtro dell aria alla catechina circa ogni 2 settimane SOSTITUZIONE DEL FILTRO DI PULIZIA DELL ARIA OPZIONE Qu...

Страница 20: ...o scambiatore di calore Questo è il rumore del refrigerante che scorre nel climatizzatore Questo è il rumore dell acqua che si condensa all interno della pompa di calore Questo é il rumore prodotto dallo sbrinamento della pompa d aria Questo suono viene avvertito quando l aria esterna viene assorbita dal tubo di scarico ruotando la cappa o il sistema di ventilazione e che fa in modo che l acqua ch...

Страница 21: ...lo Interno Esterno Funzioni Alimentazione Capacità k W Ingresso k W Peso Interno k g Esterno k g Capacità fluido k g refrigerante R410A Codice IP Interno Esterno Lato MPa aspirazione Lato MPa scarico Interno dB A Alto Medio Basso Esterno dB A MS GA20VB MS GA25VB MS GA35VB MSC GA20VB MSC GA25VB MSC GA35VB MU GA20VB MU GA25VB MU GA35VB Raffreddamento 2 3 2 5 3 45 0 715 0 775 1 12 9 10 31 30 0 60 0 6...

Отзывы: