161
OPERATING PROCEDURE
PHOTOS
Removing the compressor
(1) Remove the top panel.
(2) Remove the service panel and release the gas.
(3) Remove the rear panel, and front panel.
(4) Disconnect the compressor linking connector. (See Photo
2.)
(5) Disconnect the following connectors from the outdoor elec-
tronic control P.C. board. CN61, CN63, TAB91,CN641,
CN671, CN681, CN682, CN761, CN771,CN661,CN683.
(6) Disconnect the reactor lead wires from the te++ of
the diode stack (DS63) and from the te++ of the
capacitor (C67). (See Photo 3.)
Note: When pulling the wire, push the locking lever of the ter-
minal.
(7) Remove the inverter assembly.
(8) Remove the band that fixes the discharge pipe muffler.
(See Photo 4.)
(9) Remove the propeller fan.
(10) Remove the separator and support.
(11) Remove the reactor.
(12) Remove the terminal cover to disconnect the lead wires
from the compressor terminals.
(13) Detach the welded section of the compressor suction pipe
and discharge pipe. (See Photo 4.)
(14) Remove the compressor nuts to remove the compressor.
14-7 MXZ-18RV -
OUTDOOR UNIT
E1
Photo 3
Photo 1
Photo 2
Photo 4
Suction pipe weld-
ed section
Discharge
pipe welded
section
Separator
Outdoor
electronic
control
P.C. board
Compressor
linking con-
nector
Reactor
(in housing)
Propeller
Separator
support
Top panel
Rear panel
Service
panel
Connect
cover
Front panel
Discharge-pipe muffler
fixing band
Terminal for
capacity(C 67)
Terminal for
diode stack (DS 67)
Outdoor electric
control P.C board