34
(2) Separate correction (COOL, DRY)
(Correction by the separate superheat)
Correct the LEV separately by temperature difference
"
∆
RT" between main/sub indoor coil thermistor.
∆
RT
LEV opening correction (pulse)
MXZ-2B/3B/4B71/3C/4C71
MXZ-4B80/5B/4C80/5C/6C
4
∆
RT
2
3
2
∆
RT< 4
1
1
∆
RT< 2
0
0
MXZ-3B54VA
MXZ-3C54VA
Number of operating
unit
Capacity code
COOL (Hz)
DRY (Hz)
HEAT (Hz)
Min.
Max.
Min.
Max.
Defrost
1
1,2
20
58
23
48
72
72
3,4
20
72
23
48
92
92
7
20
85
23
48
92
92
9,10
20
101
45
48
101
100
12
34
101
58
48
101
100
13
34
101
58
48
101
100
2
~4
34
101
44
58
112
100
5~7
34
101
52
58
112
100
8~10
34
101
52
58
112
100
11~13
34
101
52
58
112
100
14~16
34
101
52
58
112
100
17~
34
101
80
58
112
100
3
3~
40
101
58
58
112
100
3-3. OPERATIONAL FREQUENCY RANGE
MXZ-2B30VA
Number of operating
unit
Capacity
code
COOL(Hz)
DRY(Hz)
HEAT(Hz)
Min
Max
Min
Max
defrost
1
1,2
40
64
40
35
97
97
3,4
40
64
44
35
97
97
2
~4
55
97
78
35
97
97
5~7
55
97
78
35
97
97
8
55
97
86
35
97
97
MXZ-2B40VA
Number of operating
unit
Capacity
code
COOL(Hz)
DRY(Hz)
HEAT(Hz)
Min
Max
Min
Max
defrost
1
1,2
30
58
30
35
98
98
3,4
30
58
34
35
98
98
7
30
68
34
35
98
98
2
~4
37
98
48
35
98
98
5~7
37
98
48
35
98
98
8~10
37
98
48
35
98
98
11
37
98
68
35
98
98
MXZ-2B52VA
Number of operating
unit
Capacity
code
COOL(Hz)
DRY(Hz)
HEAT(Hz)
Min
Max
Min
Max
defrost
1
1,2
12
48
20
21
57
57
3,4
12
48
25
21
71
71
7
12
48
25
21
80
80
9
12
48
44
21
80
80
2
~4
16
80
39
40
95
95
5~7
16
105
48
40
105
105
8~10
16
105
48
40
15
15
11~13
16
105
52
40
105
105
14
16
105
52
40
105
105