PUHZ-SHW112YHA PUHZ-SHW140YHA
TB1
TB2
MC
MF1, MF2
21S4
63H
63L
63HS
TH3
TH4
TH6
TH7
TH8
TH34
ACL1, ACL2, ACL3, ACL4
CY1, CY2
CK
RS
Terminal Block<Power Supply>
Terminal Block<Indoor/Outdoor>
Motor for Compressor
Fan Motor
Solenoid Valve (Four-Way Valve)
High Pressure Switch
Low Pressure Switch
High Pressure Sensor
Thermistor<Liquid>
Thermistor<Discharge>
Thermistor<2-Phase Pipe>
Thermistor<Ambient>
Thermistor<Heat Sink>
Thermistor<Comp. Surface>
Linear Expansion Valve
Reactor
Capacitor
Capacitor
Rush Current Protect Resistor
Power Circuit Board
Connection Terminal<U/V/W-Phase>
P. B.
TB-U/V/W
Noise Filter Circuit Board
Connection Terminal<L1/L2/L3/N-Power Supply>
N. F.
LI1, LI2. LI3, NI
Connection Terminal<L1/L2/L3/N-Power Supply>
LO1, LO2, LO3, NO
Converter Circuit Board
CONV. B.
Connection Terminal<Ground>
GD1, GD3
Connection Terminal<L1-Power Supply>
L1-A1/IN
Connection Terminal<L1-Power Supply>
L1-A2/OU
Connection Terminal<L2-Power Supply>
L2-A2/OU
Connection Terminal<L3-Power Supply>
L3-A2/OU
Connection Terminal
N-IN
Connection Terminal
CK-OU
SYMBOL
NAME
SYMBOL
NAME
SYMBOL
NAME
Connection Terminal<L1/L2/L3-Power Supply>
TB-L1/L2/L3
SW4
SW5
SW6
SW7
SW8
SW9
SWP
CN31
CNDM
CN51
SV1/CH
SS
CNM
LED1, LED2
F1, F2, F3, F4
X51, X52, X54
SW1
C. B.
Connection Terminal
TB-N
52C Relay
X52CA
Switch<Manual Defrost, Defect History,
Record Reset, Refrigerant Address>
Switch<Test Operation>
Switch<Function Switch, Model Select>
Switch<Model Select>
Switch<Function Switch>
Switch<Function Switch>
Switch<Function Switch>
Switch<Pump Down>
Connector<Emergency Operation>
Connector<Connection for Option>
Connector<Connection for Option>
Connector<Connection for Option>
Connector<Connection for Option>
Connector<Connection for Option>
LED<Operation Inspection Indicators>
FUSE<T6.3AL250V>
Relay
Controller Circuit Board
TH33
Thermistor<Ref. check>
TH32
Thermistor<Suction>
LEV-A, LEV-B, LEV-C
SYMBOL
M-NET ADAPTER
NAME
TB7
CN5
CND
CN2M
Terminal Block<M-NET connection>
Connector<Transmission>
Connector<Power Supply>
Connector<M-NET communication>
P. B.
U
POWER
SUPPLY
3N~
400V 50Hz
TB1
V W
RED
WHT
BLK
MC
7
L1
L2
L3
N
N. F.
CNAC1
(WHT)
3
1
CNDC
(PNK)
3
1
CNL
(BLU)
1
3
CNAC2
(RED)
3
1
CNCT
(RED) 1 2
LO1
LO2
LO3
NO
GD1
NI
LI1
LI2
LI3
GD3
S1
S2
S3
CK
2
3
2
3
ACL4
ACL3
ACL2
ACL1
RED
WHT
BLK
BLU
RED
WHT
BLK
BLU
TB2
CN7 (WHT)
3
1
L3
-O
U
L3
-A
2
L2
-O
U
L2
-A
2
L1
-O
U
L1
-A
2
L1-A1
L1-IN
N-IN
CK-OU
X52CA
RED
RED
BLK
BL
U
RED
RED
BLK
BLK
WHT
WHT
RED
WHT
BLK
YL
W
ORN
BRN
BLK
RED
GRN/YL
W
BLK
BLK
CONV. B.
WHT
INDOOR
UNIT
C. B.
TH6
TH7
TH4
TH3
21S4
t° t°
t°
t°
LEV-A
CNS
(WHT)
CNAC
(WHT)
CNDC
(PNK)
F2
F1
F3
F4
21S4
(GRN)
CN2
(WHT)
CN4
(WHT)
TH7/6
(RED)
TH3
(WHT)
TH4
(WHT)
TRANS
CNM
(WHT)
LED1
LED2
X52
SV1
/CH
(GRY)
X54
63H
(YLW)
2
7
1
4 1 2 2 1
1
3
1
14
1 2
1
7
3
1
1
3
1
2
3
4
3
1
3
1
LEV-A
(WHT)
5
1
SS
(WHT)
X51
3
1
MS
3~
MF1
CNF1
(WHT)
1
7
63L
63H
63L
(RED)
1
3
3
1
TH34
t°
2 1
TH34
(RED)
63HS
(WHT)
63HS
LEV-B
(RED)
M
LEV-B
5
1
M
MF2
CNF2
(WHT)
1
7
CN7
(WHT)
1
3 1 2
CN6
(WHT)
1 2
CN5
(RED)
CN2
(WHT)
1
7 1 2
CN4
(WHT)
TB-N
TB-U
TB-V
TB-W
TB-L3
TB-L2
TB-L1
TH8
t°
RS
RED
MS
3~
2
2
2
CN3S (WHT)
1
3
CNDM (WHT)
CN51 (WHT)
1
3
1
5
MS
3~
BRN
CY1 CY2
SW7
SW6
SW1
SW9
CN31
SW5
SW8
SW4
SWP
+
-
+
TH32
(BLK)
TH33
(YLW)
3
1
TH32
t°
TH33
t°
1 2
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFF
ON
112Y
MODEL
SW6
SW5-6 *2
SW5-6 *2
OFF
ON
OFF
ON
140Y
OFF
ON
1 2 3 4 5 6
1 2 3 4 5 6
MODEL
SW6
*1 MODEL SELECT
The black square( )indicates
a switch position.
*2 SW5 -1 to 5 : Function Switch
*3 Ambient temp. of ZUBADAN Flash Injection becomes effective.
The black square( )indicates a switch position.
*4 SW9-1 to 2 : Function Switch
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
SW9-3,4 *4
Ambient temp.
3°C or less
(lnitial setting)
0°C or less
SW9-3,4 *4
Ambient temp.
SW9-3,4 *4
Ambient temp.
–3°C or less
–6°C or less
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
SW9-3,4 *4
Ambient temp.
*1
*1
*3
CNVMNT
(WHT)
CNMNT
(WHT)
3
1
1
5
CN5
(WHT)
3
1
TB7
2
1
CND
(WHT)
CN2M
(WHT)
M-NET
A B S
When M-NET adapter is connected
5
3
5
1
M-NET ADAPTER
3
5
5
LEV-C
(BLU
)
5
1
LEV-C
5
M
OCH526