134
Slim Air Conditioners System
Remote controller
connection circuit
(Controller cable)
Outdoor unit
OC
Indoor unit
IC
Wired
remote
controller R
OC
IC-1
IC-2
3
3
3
3
IC-3
IC-4
OC
IC-1
IC-2
3
3
3
IC-3
OC
IC-1
IC-2
3
3
OC
IC-1
3
R-1
R-2
2
2
2
R-1
R-2
2
2
R-1
R-2
2
R-1
R-2
2
2
OC
IC-1
IC-2
3
3
3
3
IC-3
IC-4
OC
IC-1
IC-2
3
3
3
IC-3
OC
IC-1
IC-2
3
3
2
OC
IC-1
3
R-1
R-2
2
2
R-1
2
R-2
2
R-1
2
R-2
2
R-1
R-2
2
Standard 1:1
Simultaneous Twin
Simultaneous Triple
Simultaneous Quadro
Outdoor unit
OC
Indoor unit
IC
Wired
remote
controller R
15-3. Two remote controller control operation
(1) Two Wired Remote Controllers
(OC: Outdoor unit IC: Indoor unit R-1 Master remote controller R-2 Slave remote controller)
(Reference)
1
1
If simultaneous twin, triple or four, connect the remote controller to anyone of the indoor units. Can control all functions
of the indoor unit even if different models (different types) are mixed.
2
2
Do not use crossover wiring among indoor units with simultaneous twin, triple or quadro units. (Prohibited item.)
3
3
On the main body of each remote controller, set the "Main/Sub selection switch" on one unit to "Main" (factory setting)
and the other to "Sub". If MA remote controller, set switch No.1 to ON [(Main) Factory setting] and remaining switches
to OFF (Sub).
(2) Two wireless remote controllers
(OC: Outdoor unit IC: Indoor unit R: Master remote controller R’: Wireless remote controller optical receiver section)
Slim Air Conditioners System
Remote controller
optical receiver
section connection
circuit
Outdoor unit
OC
Cannot use two remote
controllers.
Indoor unit
IC
OC
IC-1
IC-2
3
3
3
3
IC-3
IC-4
OC
IC-1
IC-2
3
3
3
IC-3
OC
IC-1
IC-2
3
3
R-1
R-2
9
9
9
9
9
9
R-1
R-2
R-1
R-2
Standard 1:1
Simultaneous Twin
Simultaneous Triple
Simultaneous Quadro
Wireless
remote controller
optical receiver
section R'
MA remote controller
(Reference)
1
1
If simultaneous twin, triple or four, connect the remote controller to anyone of the indoor units. Can control all functions
of the indoor unit even if different models (different types) are mixed.
2
2
Do not use crossover wiring among indoor units with simultaneous twin, triple or quadro units. (Prohibited item.)
3
3
Standard 1:1 While it is not possible to connect two remote controller optical sections to an indoor unit, it is possible to
connect one each of the remote controller optical sections to each indoor unit. When this is done, all pair numbers are
set to "0" (No setting required. Factory setting) and they can be stopped and started simultaneously.