OUTDOOR UNIT
PUH-P25VGAA
PUH-P35VGAA
PUH-P35YGAA
PU-P35VGAA
PU-P35YGAA
3
2
1
T
S
R
w
1 248
w
1 196
500
Power Supply Wiring Hole
(2-
[
27Knock-Out)
Right Piping Hole
(Knock-Out)
Power Supply Wiring Hole
(2-
[
27Knock-Out)
T
erminal Connections
Left...Power supply Wiring
Right..Indoor/Outdoor Wiring
70
70
155
155
155
109
30
215
85
Bottom Piping Hole
(Knock-Out)
Drain Hole
(5-
[
33holes)
18
18
424
900
318
Handle for moving
Earth Point
Service Panel
Front Piping Cover
Rear Piping Cover
1
2
Side Air
Intake
200
200
53
370
(14)
412
29
330
55
43
51
Rear Air
Intake
Air Discharge
2-U Shaped notched holes
(Foundation Bolt M10)
2-12x40 oval holes
(Foundation Bolt M10)
20
28
58
Installation Feet
Rear
Air
Intake
Side
Air
Intake
Handle for
moving
3
230
220
220
230
637
650
30
30
Rear T
runking
Hole
(Knock-Out)
< Rear Side >
Power Supply Wiring Hole
(2-
[
27Knock-Out)
40
33
22
55
68
63
65
92
Rear Piping Hole
(Knock-Out)
[
92
Piping Knock-Out Hole Details
. .
Refrigerant GAS pipe connection (FLARE)P35V(Y)GAA:
[
15.88 (5/8F)
. .
Refrigerant LIQUID pipe connection (FLARE)P35V(Y)GAA:
[
9.52 (3/8F)
. .
Height of ST
OP
V
A
L
V
E connection location.
1
2
Front T
runking
Hole
(Knock-Out)
< Right Side >
< Front Side >
Explanation of Notes
40
68
63
22
55
65
92
33
27100
50
50
100
33
[
92
Front Piping Hole
(Knock-Out)
5540
3
. .
3-
[
3.6 holes (for securing the top of the unit)
These holes are provided for cases where the unit must
be secured by the base
AND by the top surface.
Use Self
T
apping screws 5 x L15 or less.(Obtained locally)
w
1
. .
Refrigerant GAS pipe connection (FLARE)P25VGAA
:
[
12.7 (1/2F)
. .
Refrigerant LIQUID pipe connection (FLARE)P25VGAA
:
[
6.35 (1/4F)
1
2
O
ve
r 10m
m
F
R
E
E
O
ver 500m
m
Less than
30mm
FREE SP
ACE (Around the Unit)
Piping and wiring connections
can be made from 4 directions:
Front, Right, Rear and Below
.
FOUNDA
TION BOL
TS
1
The diagram below shows a
basic example.
Explanation of particular details are
given in the installation manuals etc.
SER
VICE SP
ACE
Dimensions of space needed
for service access are
shown in the below diagram.
2
Over500
Over500
PIPING-WIRING DIRECTIONS
4
3
FOUNDA
TION
<Foundation bolt height>
Please secure the unit firmly
with 4 foundation (M10) bolts.
(Bolts and washers must be
purchased locally).
Service Space
O
ve
r 1
00m
m
O
ver 1
0m
m
Over10
Over100
Unit : mm
OCS02-2.qxp 05.7.20 5:15 PM Page 52
Содержание Mr.Slim PU-P100VGAA
Страница 56: ...56 WIRED REMOTE CONTROLLER Unit mm 130 120 19 ...
Страница 57: ...57 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Страница 60: ...60 PEAD RP35EA PEAD RP50EA PEAD RP60EA PEAD RP71EA PEAD RP100EA PEAD RP125EA PEAD RP140EA ...
Страница 61: ...61 PEHD P35EAH PEHD P50EAH PEHD P60EAH PEHD P71EAH PEHD P100EAH PEHD P125EAH PEHD P140EAH ...
Страница 62: ...62 PEAD P60GA PEAD P71GA PEAD P100GA ...
Страница 77: ...77 8 2 PLA RP AA PLH P AAH 8 2 1 FRESH AIR INTAKE AMOUNT ...
Страница 78: ...78 8 2 2 BRANCH DUCT Installation at site ...
Страница 89: ...89 PEAD RP60GA PEAD RP71GA ...
Страница 90: ...90 PEAD RP100GA ...
Страница 95: ...95 ...