en
Vane setting
Direct
Indirect
Cooling
horizontal → swing
keep horizontal
Heating
keep downward
downward → horizontal
2
Select the menu with the [F4] but-
ton.
Default → Area → Direct/Indirect
→ Default…
Default: The vanes move the
same as during normal operation.
“Area”*: The vanes move to the
down airflow direction toward ar
-
eas with a high floor temperature
during cooling mode and toward
areas with a low floor temperature
during heating mode. Otherwise,
the vanes move to the horizontal
airflow direction.
“Direct/Indirect”*: The vanes
automatically move relative to
the areas where persons are
detected.
The vanes operate as indicated in
the following table.
* In order to enable this function,
the airflow direction must be set to
“Auto”.
3. Operation
3.6. 3D i-see Sensor setting
Note:
This function cannot be set depending on the outdoor unit to be
connected.
3.6.1 3D i-see Sensor setting
3
Select “3D i-See sensor” with the
[F1] or [F2] button, and press the
[SELECT] button.
Direct/Indirect setting
: Direct
: Indirect
: Indirect
: Direct
Select:
Outlet
Angle
F1
F2
F3
F4
■
i-see button (Wireless remote controller)
1
Each time
is pressed during operation, the setting changes in
the following order: OFF → Direct → Indirect.
Display
Setting
OFF
Direct
Indirect
When the setting is changed from OFF to Direct or Indirect, the vane setting
changes to "Auto". This setting is applied collectively to all of the vanes.
Air distribution
Select:
Cur.
Ref. address
Unit No.
Auto vane
Direct/Indirect setting
All
Direct/Indirect
F1
F2
F3
F4
3
When Direct/Indirect is selected,
set each air outlet.
Select the air outlet with the [F1]
or [F2] button, and change the
setting with the [F4] button.
After changing the settings for all
of the air outlets, press the [SE-
LECT] button to save the settings.
1
Select “Operation” from the Main
menu, and press the [SELECT]
button.
Operation
Main
Main menu
F1
F2
F3
F4
3.6.2 Air distribution
4
Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT] button.
• Air distribution
Select the airflow direction control
method when the airflow direction
is set to “Auto”.
• Energy saving option
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-see Sensor.
• Seasonal airflow
When the thermostat turns off, the
fan and the vanes operate accord-
ing to the control settings.
1
Move the cursor to “Ref. address”
or “Unit No.” with the [F1] button
to select.
Select the refrigerant address and
the unit number for the units to
whose vanes are to be fixed, with
the [F2] or [F3] button, and press
the [SELECT] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm
the unit.
The vane of only the target indoor
unit is pointing downward.
2
Select “Comfort” from the
Operation menu, and press the
[SELECT] button.
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu:
F1
F2
F3
F4
Comfort
Cursor
Manual vane angle
3D i-See sensor
Setting display:
F1
F2
F3
F4
3D i-See sensor
Cursor
Setting display:
Air distribution
Energy saving option
Seasonal airflow
F1
F2
F3
F4
Air distribution
Input display:
Cur.
Address
Check
Ref. address
Unit No.
Identify unit Check button
F1
F2
F3
F4