2. Installation location

3. Installing the indoor unit

3.1. Check the indoor unit accessories (Fig. 3-1)

The indoor unit should be supplied with the following accessories.

PARTNUMBER

ACCESSORY

QUANTITY

LOCATION OF SETTING

1

Wall-fixing bracket

1

Fix at the back of the unit

2

Tapping screw 4 

×

 35

12

3

Insulation material

2

4

Band

4 (large) + 3 (small)

5

Felt tape

3

6

Drain socket

1

7

Wireless remote controller

1

8

Remote controller holder

1

9

Alkali batteries

2

Fig. 2-1

2.1. Outline dimensions (Indoor unit) (Fig. 2-1)

Select a proper position allowing the following clearances for installation and mainte-
nance.

(mm)

Models

W

D

H

A

B

C

E

F

RP2.5, 3

1400

235

340

Min. 150

Min. 50

Min. 30

Min. 250 Min. 150

RP4

1680

235

340

Min. 150

Min. 50

Min. 30

Min. 250 Min. 150

 Warning:

Mount the indoor unit on a ceiling strong enough to withstand the weight of the
unit.

2.2. Outline dimensions (Outdoor unit)

Refer to the outdoor unit installation manual.

D

A

C

F

E

H

W

B

Set inside the unit

990

245

285

455

10

×

91=(910)

19

10

184

280

60

30

30

30

29

80

900

91

90

610

314

280

180

240

225

18

18

A

B

C

G

I

H

F

E

D

1270

18 18

900

19

91

295

225

240

180

280

314

90

750

60

280

80

29

30

30

30

10

184

13

×

91=(1183)

245

285

595

I

H

H

E

D

B

G

A

C

F

1

 RP2.5, RP3

(mm)

1

2

3

4

5

6

7

8

9

A

C

D

E

B

2

 RP4

Fig. 3-1

Fig. 3-2

Fig. 3-3

3.2. Installing the wall mounting fixture (Fig. 3-2)

1) Setting the wall mounting fixture and piping positions

s

Using the wall mounting fixture, determine the unit’s installation position
and the locations of the piping holes to be drilled.

 Warning:

Before drilling a hole in the wall, you must consult the building contractor.

A

Indoor unit center line

B

Left drain range

C

Right drain range

D

Hole for tapping screw

E

Bolt hole

F

Hole for tapping screw

G

Contour of the unit

H

Knockout hole for left rear piping

I

Rear piping access hole (90-100 mm dia.)

2) Drilling the piping hole (Fig. 3-3)

s

Use a core drill to make a hole of 90-100 mm diameter in the wall in the
piping direction, at the position shown in the diagram to the left.

s

The hole should incline so that the outside opening is lower than the inside
opening.

s

Insert a sleeve (with a 90 mm diameter and purchased locally) through the
hole.

Note:
The purpose of the hole’s inclination is to promote drain flow.

A

Sleeve

B

Hole

C

(Indoors)

D

Wall

E

(Outdoors)

Содержание Mr.SLIM PKA-RP FAL

Страница 1: ...Air Conditioners PKA RP FAL English INSTALLATION MANUAL For safe and correct use please read this installation manual thoroughly before installing the air conditioner unit FOR INSTALLER ...

Страница 2: ... combustible gas accumulates around the unit fire or explo sion may result Do not keep food plants caged pets artwork or precision instruments in the direct airflow of the indoor unit or too close to the unit as these items can be damaged by temperature changes or dripping water When the room humidity exceeds 80 or when the drainpipe is clogged wa ter may drip from the indoor unit Do not install t...

Страница 3: ...80 240 225 18 18 A B C G I H F E D 1270 18 18 900 19 91 295 225 240 180 280 314 90 750 60 280 80 29 30 30 30 10 184 13 91 1183 245 285 595 I H H E D B G A C F 1 RP2 5 RP3 mm 1 2 3 4 5 6 7 8 9 A C D E B 2 RP4 Fig 3 1 Fig 3 2 Fig 3 3 3 2 Installing the wall mounting fixture Fig 3 2 1 Setting the wall mounting fixture and piping positions s Using the wall mounting fixture determine the unit s install...

Страница 4: ...pipe drain pipes internal external connection lines etc are to be embedded into the wall in advance the extruding pipes etc may have to be bent and have their length modified to the unit Make the pipes to be embedded slightly longer than necessary and install A Right side panel C On site piping B Through hole D Wall fixing bracket 1 2 Remove the five screws indicated by the arrows in the diagram F...

Страница 5: ...R 0 8 A 45 2 B C D Fig 4 1 C Apply refrigerating machine oil over the entire flare seat surface D Use the flare nuts as follows 3 4 Mounting the indoor unit Fig 3 11 1 Make sure to hang the metal catches of the indoor unit over the hooks of the wall mounting fixture 2 When the piping has been completed use the securing screws to fix the indoor unit on the wall mounting fixture Note Check that the ...

Страница 6: ...ed according to this Installation Manual to en sure correct drainage Thermal insulation of the drain pipes is necessary to prevent condensation If the drain pipes are not properly installed and insu lated condensation may drip on the ceiling floor or other possessions 6 Electrical work 6 1 Indoor unit Fig 6 1 1 Remove the right side panel To do this remove the screws on the lower and right sides R...

Страница 7: ...ant to set 4 Press the SET button with something sharp at the end Set pair number is lighted for three seconds then turned off A Pair No of wireless remote controller Indoor PC board 0 Factory setting 1 Cut J41 2 Cut J42 3 9 Cut J41 J42 ON OFF TEMP FAN VANE TEST RUN AUTO STOP AUTO START h min LOUVER MODE CHECK RESET SET CLOCK MODELSELECT 1 4 3 A 2 Fig 6 4 3 CHECK 4 CHECK ON OFF TEMP FAN VANE TEST ...

Страница 8: ...he resistance between the power supply terminals and ground is at least 1 0MΩ s Do not carry out this test on the control wiring low voltage circuit termi nals Warning Do not use the air conditioner if the insulation resistance is less than 1 0MΩ Insulation resistance Turn on the power at least 12 hours before starting operation Starting operation immediately after turning on the main power switch...

Страница 9: ... operation lamp does not light up For about 2 minutes following power on After about 2 minutes has expired following power on After LED 1 2 are lighted LED 2 is turned off then only LED 1 is lighted Correct operation Only LED 1 is lighted LED 1 2 blink Only LED 1 is lighted LED 1 blinks twice LED 2 blinks once For about 2 minutes following power on operation of the remote controller is not possibl...

Страница 10: ... EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Japan BG79U167H01 The product at hand is based on the following EU regulations ...

Отзывы: