 Warning:

Do not remove the front panel or the fan guard from the outdoor unit
when it is running. You could be injured if you touch rotating, hot or high-
voltage parts.

Never insert fingers, sticks etc. into the intakes or outlets, otherwise in-
jury may result, since the fan inside the unit rotates at high speed. Exer-
cise particular care when children are present.

If you detect odd smells, stop using the unit, turn off the power switch
and consult your dealer. Otherwise, a breakdown, electric shock or fire
may result.

When you notice exceptionally abnormal noise or vibration, stop opera-
tion, turn off the power switch, and contact your dealer.

Do not over-cool. The most suitable inside temperature is one that is
within 5 °C of the outside temperature.

Do not leave handicapped people or infants sitting or standing in the path
of the airflow from the air-conditioner. This could cause health problems.

 Caution:

Do not direct the airflow at plants or caged pets.

Ventilate the room frequently. If the unit is operated continuously in a
closed room for a long period of time, the air will become stale.

In case of failure

 Warning:

Never remodel the air conditioner. Consult your dealer for any repair or serv-
ice. Improper repair work can result in water leakage, electric shock, fire, etc.

If the remote controller displays an error indication, the air conditioner
does not run, or there is any abnormality, stop operation and contact

your dealer. Leaving the unit as it is under such conditions can result in
fire or failure.

If the power breaker is frequently activated, get in touch with your dealer.
Leaving it as it is can result in fire or failure.

If the refrigeration gas blows out or leaks, stop the operation of the air
conditioner, thoroughly ventilate the room, and contact your dealer. Leav-
ing the unit as it is can result in accidents due to oxygen deficiency.

When the air conditioner is not to be used for a long

time

If the air conditioner is not to be used for a long time due to a seasonal
change, etc., run it for 4 - 5 hours with the air blowing until the inside is
completely dry. Failing to do so can result in the growth of unhygienic,
unhealthy mold in scattered areas throughout the room.

When it is not to be used for an extended time, keep the [power supply]
turned OFF.
If the power supply is kept on, several watts or several tens of watts will
be wasted. Also, the accumulation of dust, etc., can result in fire.

Keep the power switched ON for more than 12 hours before starting op-
eration. Do not turn the power supply OFF during seasons of heavy use.
Doing so can result in failure.

1.3. Disposing of the unit

 Warning:

When you need to dispose of the unit, consult your dealer. If pipes are re-
moved incorrectly, refrigerant (fluorocarbon gas) may blow out and come
into contact with your skin, causing injury. Releasing refrigerant into the
atmosphere also damages the environment.

2. How to operate

Before starting operation

Start running after the “PLEASE WAIT” display has disappeared. The “PLEASE
WAIT” display briefly appears on the room temperature display (max. 3 min-
utes) when the power is turned on and after a power failure. This does not
indicate any failure of the air-conditioner.

The choice of indoor unit operation mode is limited by the operation status of
the outdoor unit to which a given indoor unit is connected. If an outdoor unit
and some of the indoor units that are connected to the outdoor units are al-
ready operating in the cooling mode, for example, only the cooling mode is
available for the rest of the units in the same group. If a different mode is re-
quested, the symbol that corresponds to the requested mode will blink, notify-
ing the user that the mode is currently unavailable. The same is true for the dry
and heating mode. This restriction, however, does not apply to the models that
support a simultaneous cooling/heating function.

The outdoor units stop when all the indoor units connected to the counterpart
outdoor units stop.

During heating operation, even if the indoor unit is set to operation while the
outdoor unit is in defrosting operation, operation starts after the defrosting op-
eration of the outdoor unit has ended.

2.1. ON/OFF

Start an operation

1. Press the 

B

 [ON/OFF] button

P

 Operation lamp lights up and operation starts.

Stop an operation

1. Press the 

B

 [ON/OFF] button again

Operation lamp goes off and operation stops.

Once the Buttons have been set, pressing of the [ON/OFF] Button only can
repeat the same operation thereafter.

During operation, the operation lamp above the [ON/OFF] button lights up.

 Caution:

Even if the [ON/OFF] Button is pressed immediately after the operation is
once stopped, operation is not restarted for about 3 minutes. This function
protects the machine. It automatically starts operation after the lapse of
approximately 3 minutes.

2.2. Selecting operation

When selecting operation

1. Press the 

3

 

[Mode (Back)] Button

Consecutive press of the selecting operation Button switches the operation
over to 

E

 “

COOL”, “ DRY”, “

FAN”, (“

AUTO”), and (“

HEAT”). For

the contents of operation, check the display.

For cooling

Press the 

3

 [Mode (Back)] Button and bring up the “

COOL

” display.

For dry

Press the 

3

 [Mode (Back)] Button and bring up the “

DRY

” display.

The indoor fan turns to the low-speed operation, disabling the change of fan
speed.

Dry operation cannot be carried out at room  temperature of less than 18 °C.

ON/OFF 

CHECK

CLEAR

MENU

ON/OFF

TEST

TEMP.

CLOCK

OPERATION

BACK

DAY

MONITOR/SET

1

E

2

3

6 8

B

P

7

FILTER

ERROR CODE

TIME

ON

OFF

Hr

AFTER

SUN

MON TUE WED THU

FRI

SAT

TIMER

AFTER

ONLY 1Hr.

˚C

˚F

WEEKLY

SIMPLE

AUTO OFF

FILTER

FUNCTION

˚C

˚F

Содержание Mr.Slim PEA-RP170WHA

Страница 1: ...I Air Conditioners INDOOR UNIT PEA RP170 200 250 WHA GB OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit ...

Страница 2: ...and section of the remote controller Doing so can result in the erroneous measurement of room tem perature Remote controller Button 2 GB ON OFF FILTER CHECK CLEAR MENU ON OFF TEST TEMP CLOCK OPERATION BACK DAY MONITOR SET 1 2 3 4 D 5 6 8 9 C 0 A B 7 A Current time Timer time B Centralized control indicator C Timer OFF indicator D Timer mode indicator E Operation mode display COOL DRY AUTO FAN HEAT...

Страница 3: ...aution The outdoor unit should be installed in a location where air and noise emit ted by the unit will not disturb the neighbours 2 Indoor unit Warning The indoor unit should be securely installed If the unit is loosely mounted it may fall causing injury 3 Remote controller Warning The remote controller should be installed in such a way that children cannot play with it 4 Drain hose Caution Make ...

Страница 4: ...ult your dealer If pipes are re moved incorrectly refrigerant fluorocarbon gas may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environment 2 How to operate Before starting operation Start running after the PLEASE WAIT display has disappeared The PLEASE WAIT display briefly appears on the room temperature display max 3 min ...

Страница 5: ...n the indoor fan some times rotates to eliminate extra heat generated by the electric heater etc The fan speed comes to low or high 2 3 Room temperature adjustment To change room temperature Press the 1 Set Temperature Button and set the room temperature of your choice Pressing or once changes the setting by 1 C If the pressing is continued the setting continues to change by 1 C Indoor temperature...

Страница 6: ...necessary When gas appliances are used together with the air conditioner special precautions must be taken If the LOSSNAY ventilation unit developed by our company is used you can perform ventilation with less waste For details on this unit consult with your dealer 4 Caring for the machine Always have filter field supply maintenance performed by authorized tech nicians Before care taking turn the ...

Страница 7: ...et of the indoor and outdoor units The filter is filled with dust and dirt When other indoor units are engaged in cooling opera tion the machine stops after running a drain up mecha nism for 3 minutes when air cooling operation is stopped When other indoor units are engaged in cooling opera tion drained water is brought in If the drain water is collected the drain up mechanism initiates a draining...

Страница 8: ...t with your dealer Regarding transfer of installation When removing and reinstalling the air conditioner when you enlarge your home remodel or move consult with your dealer in advance to ascertain the cost of the professional engineering work required for transferring the installa tion Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can resul...

Страница 9: ...GB E F I NL E P GR RU TR ...

Страница 10: ...GB E F NL E P GR RU TR ...

Страница 11: ...GB E F I NL E P GR RU TR ...

Страница 12: ...ss telephone number on this manual before handing it to the customer The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC This product is designed and intended for use in the residential commer cial and light industrial environment ...

Отзывы: