background image

6

GB

D

F

E

I

NL

P

GR

RU

TR

GB

GB

GB

GB

GB

3. The smart way to use

Even minimal steps to care for your air conditioner can help make its use far
more effective in terms of air-conditioning effect, electricity charges, etc.

Set the right room temperature

In cooling operation, a temperature difference of about 5 °C between indoors
and outdoors is optimum.

If the room temperature is raised by 1 °C during air-cooling operation, about
10 % electric power can be saved.

Excessive cooling is bad for health. It also results in the waste of electric power.

Clean the filter (field supply) thoroughly

If the screen of the air filter (field supply) becomes clogged, the airflow and air-
conditioning effect can be significantly reduced.
Further, if the condition is left unattended, failure can result. It is particularly
important to clean the filter at the beginning of the cooling and heating sea-
sons. (When profuse dust and dirt have accumulated, clean the filter thoroughly.)

Prevent intrusion of heat during air-cooling

To prevent the intrusion of heat during cooling operation, provide a curtain or a
blind on the window to block out direct sunlight. Also, do not open the entrance
or exit except in cases of dire necessity.

Carry out ventilation sometimes

Since the air periodically gets dirty in a room that is kept closed for a long time,
ventilation is sometimes necessary. When gas appliances are used together
with the air conditioner, special precautions must be taken. If the “LOSSNAY”
ventilation unit developed by our company is used, you can perform ventilation
with less waste. For details on this unit, consult with your dealer.

4. Caring for the machine

Always have filter (field supply) maintenance performed by authorized tech-
nicians.
Before care-taking, turn the power supply OFF.

 Caution:

Before you start cleaning, stop operation and turn OFF the power supply.
Remember that the fan is rotating inside at high speed, posing a serious
risk of injury.

Indoor units are not equipped with filters. However, filter (field supply)
must be installed in the return air to remove the dust of sucked-in air.
(The standard filter should normally be cleaned once a week.)

The life of the filter depends on where the unit is installed and how it is
operated.

How to clean

Clear dust away lightly or clean it up with a vacuum cleaner. In the case of
severe staining, wash the filter in lukewarm water mixed with dissolved neutral
detergent or water, and then rinse off the detergent completely. After washing,
dry it and fix it back into place.

 Caution:

Do not dry the filter by exposing it to direct sunlight or warming it using
fire, etc. Doing so can result in the deformation of the filter.

Washing it in hot water (more than 50 °C) can also result in deformation.

 Caution:

Never pour water or flammable sprays onto the air conditioner. Cleaning using
these methods can result in the failure of the air conditioner, electric shock,
or fire.

Содержание Mr.Slim PEA-RP170WHA

Страница 1: ...I Air Conditioners INDOOR UNIT PEA RP170 200 250 WHA GB OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit ...

Страница 2: ...and section of the remote controller Doing so can result in the erroneous measurement of room tem perature Remote controller Button 2 GB ON OFF FILTER CHECK CLEAR MENU ON OFF TEST TEMP CLOCK OPERATION BACK DAY MONITOR SET 1 2 3 4 D 5 6 8 9 C 0 A B 7 A Current time Timer time B Centralized control indicator C Timer OFF indicator D Timer mode indicator E Operation mode display COOL DRY AUTO FAN HEAT...

Страница 3: ...aution The outdoor unit should be installed in a location where air and noise emit ted by the unit will not disturb the neighbours 2 Indoor unit Warning The indoor unit should be securely installed If the unit is loosely mounted it may fall causing injury 3 Remote controller Warning The remote controller should be installed in such a way that children cannot play with it 4 Drain hose Caution Make ...

Страница 4: ...ult your dealer If pipes are re moved incorrectly refrigerant fluorocarbon gas may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environment 2 How to operate Before starting operation Start running after the PLEASE WAIT display has disappeared The PLEASE WAIT display briefly appears on the room temperature display max 3 min ...

Страница 5: ...n the indoor fan some times rotates to eliminate extra heat generated by the electric heater etc The fan speed comes to low or high 2 3 Room temperature adjustment To change room temperature Press the 1 Set Temperature Button and set the room temperature of your choice Pressing or once changes the setting by 1 C If the pressing is continued the setting continues to change by 1 C Indoor temperature...

Страница 6: ...necessary When gas appliances are used together with the air conditioner special precautions must be taken If the LOSSNAY ventilation unit developed by our company is used you can perform ventilation with less waste For details on this unit consult with your dealer 4 Caring for the machine Always have filter field supply maintenance performed by authorized tech nicians Before care taking turn the ...

Страница 7: ...et of the indoor and outdoor units The filter is filled with dust and dirt When other indoor units are engaged in cooling opera tion the machine stops after running a drain up mecha nism for 3 minutes when air cooling operation is stopped When other indoor units are engaged in cooling opera tion drained water is brought in If the drain water is collected the drain up mechanism initiates a draining...

Страница 8: ...t with your dealer Regarding transfer of installation When removing and reinstalling the air conditioner when you enlarge your home remodel or move consult with your dealer in advance to ascertain the cost of the professional engineering work required for transferring the installa tion Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can resul...

Страница 9: ...GB E F I NL E P GR RU TR ...

Страница 10: ...GB E F NL E P GR RU TR ...

Страница 11: ...GB E F I NL E P GR RU TR ...

Страница 12: ...ss telephone number on this manual before handing it to the customer The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC This product is designed and intended for use in the residential commer cial and light industrial environment ...

Отзывы: