Mitsubishi Electric Mr.SLIM PCA-RP KAQ Скачать руководство пользователя страница 17

17

10. Trouble Shooting

Having trouble?

Here is the solution. (Unit is operating normally.)

Air conditioner does not heat or cool well.

 

 Clean the filter. (Airflow is reduced when the filter is dirty or clogged.)

 

 Check the temperature adjustment and adjust the set temperature.

 

 Make sure that there is plenty of space around the outdoor unit. Is the 
indoor unit air intake or outlet blocked?

  

 

 Has a door or window been left open?

When heating operation starts, warm air does not blow from the indoor 
unit soon.

 

 Warm air does not blow until the indoor unit has sufficiently warmed up.

During heating mode, the air conditioner stops before the set room tem-
perature is reached.

 

 When the outdoor temperature is low and the humidity is high, frost 
may form on the outdoor unit. If this occurs, the outdoor unit performs 
a defrosting operation. Normal operation should begin after approxi-
mately 10 minutes.

Airflow direction changes during operation or airflow direction cannot be 
set.

 

During cooling mode, the vanes automatically move to the horizontal 
(down) position after 1 hour when the down (horizontal) airflow direc-
tion is selected. This is to prevent water from forming and dripping from 
the vanes.

 

During heating mode, the vanes automatically move to the horizontal 
airflow direction when the airflow temperature is low or during defrost-
ing mode.

When the airflow direction is changed, the vanes always move up and 
down past the set position before finally stopping at the position.

 

 When the airflow direction is changed, the vanes move to the set posi-
tion after detecting the base position.

A flowing water sound or occasional hissing sound is heard.

 

These sounds can be heard when refrigerant is flowing in the air condi-
tioner or when the refrigerant flow is changing.

A cracking or creaking sound is heard.

 

 These sounds can be heard when parts rub against each due to expan-
sion and contraction from temperature changes.

The room has an unpleasant odor.

 

 The indoor unit draws in air that contains gases produced from the 
walls, carpeting, and furniture as well as odors trapped in clothing, and 
then blows this air back into the room. 

A white mist or vapor is emitted from the indoor unit.

 

If the indoor temperature and the humidity are high, this condition may 
occur when operation starts.

 

During defrosting mode, cool airflow may blow down and appear like a 
mist.

Water or vapor is emitted from the outdoor unit.

 

During cooling mode, water may form and drip from the cool pipes and  

    joints.

 

  During heating mode, water may form and drip from the heat exchang-
er.

 

  During defrosting mode, water on the heat exchanger evaporates and 
water vapor may be emitted.

The operation indicator does not appear in the remote controller display.

 

  Turn on the power switch. “

” will appear in the remote controller dis-

play.

” appears in the remote controller display.

 

  During central control, “

” appears in the remote controller display 

and air conditioner operation cannot be started or stopped using the 
remote controller.

When restarting the air conditioner soon after stopping it, it does not oper-
ate even though the ON/OFF button is pressed.

 

 Wait approximately 3 minutes. (Operation has stopped to protect the air 
conditioner.)

Air conditioner operates without the ON/OFF button being pressed.

 

Is the on timer set?

  Press the ON/OFF button to stop operation.

 

  Is the air conditioner connected to a central remote controller?

  Consult the concerned people who control the air conditioner.

 

 Does “

” appear in the remote controller display?

  Consult the concerned people who control the air conditioner.

 

  Has the auto recovery feature from power failures been set?

  Press the ON/OFF button to stop operation.

Air conditioner stops without the ON/OFF button being pressed.

 

Is the off timer set?

  Press the ON/OFF button to restart operation.

 

Is the air conditioner connected to a central remote controller?

  Consult the concerned people who control the air conditioner.

 

  Does “

” appear in the remote controller display?

  Consult the concerned people who control the air conditioner.

Remote controller timer operation cannot be set.

 

Are timer settings invalid? 

   If the timer can be set, 

WEEKLY

 , 

SIMPLE

 , or 

AUTO OFF

 appears 

in the remote controller display.

“PLEASE WAIT” appears in the remote controller display.

 

The initial settings are being performed. Wait approximately 3 minutes.

An error code appears in the remote controller display.

 

The protection devices have operated to protect the air conditioner.

 

  Do not attempt to repair this equipment by yourself.

   Turn off the power switch immediately and consult your dealer. Be sure 

to provide the dealer with the model name and information that ap-
peared in the remote controller display.

Содержание Mr.SLIM PCA-RP KAQ

Страница 1: ...o correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används Français Deutsch English Nederlands Español Italiano Português Dans...

Страница 2: ... for EU countries only This symbol mark is according to the directive 2002 96 EC Article 10 Information for users and Annex IV and or to the directive 2006 66 EC Article 20 Information for end users and Annex II Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and or reused This symbol means that electrical and electroni...

Страница 3: ... The indicator shows the direc tion of the outcoming airflow Day of Week Shows the current day of the week Room Temperature display Shows the room temperature The room temperature display range is 8 39 C The display blinks if the temperature is less than 8 C or 39 C or more Time Timer Display Shows the current time unless the simple or Auto Off timer is set If the simple or Auto Off timer is set sh...

Страница 4: ...ndoor Outdoor Connection wire Ref Pipes Indoor Unit PSA RP KA Fan speed 3 speeds Auto Vane Manual Louver Auto with swing Filter Long life Filter cleaning indication 2 500 hr PSA RP KA Floor Standing Air intake Filter Air outlet Vane Louver Remote controller ...

Страница 5: ...ton as necessary to set the time As you hold the button down the time at will increment first in one minute intervals then in ten minute intervals and then in 1 hour intervals 4 After making the appropriate settings at Steps 2 and 3 press the Filter button to lock in the values 5 Operation F C TIMER MON OFF WEEKLY SUN MON TUE WED THU FRI SAT WEEKLY F C C TIME SUN Function Selection of remote contro...

Страница 6: ...inutes the air conditioner switches to cooling mode In the same way if the room temperature remains 2 C or more below the set temperature for 15 minutes the air conditioner switches to heating mode Because the room temperature is automatically adjusted in order to maintain a fixed effective temperature cooling operation is performed a few degrees warmer and heating operation is performed a few de g...

Страница 7: ...ing operation the arrow display move to the left and right Low High 6 Timer 6 1 For Wired Remote controller You can use Function Selection of remote controller to select which of 3 types of timer to use Weekly timer Simple timer or Auto Off timer 6 1 1 Weekly Timer The weekly timer can be used to set up to 8 operations for each day of the week Each operation may consist of any of the following ON ...

Страница 8: ...you have set 2 or more different operations for exactly the same time only the operation with the highest Operation No will be carried out 9 Repeat Steps 3 to 8 as necessary to fill as many of the available cells as you wish 10 Press the mode Return button to return to the standard control screen and complete the setting procedure 11 To activate the timer press the Timer On Off button so that the T...

Страница 9: ... OFF indication appears at ON timer The air conditioner will start operation when the specified number of hours has elapsed OFF timer The air conditioner will stop operation when the specified number of hours has elapsed Timer Setting TIMER ON OFF Hr AFTER SIMPLE C C SIMPLE 1 Be sure that the simple timer indicator is visible on the screen at 2 Press the Timer Menu button so that the Monitor appears...

Страница 10: ...of the following conditions is in effect The timer is off the system is in malfunction state a test run is in prog ress the remote controller is undergoing self check or remote control ler check the user is in the process of selecting a function the user is in the process of setting the timer the system is under central control Under these conditions On Off operation is prohibited AFTER OFF AUTO O...

Страница 11: ...s as described above C C TIME SUN FUNCTION ON OFF TEMP CLEAR If you press a locked button the Locked indication at will blink on the display C C FUNCTION C C FUNCTION C C If only the error code is blinking while the ON lamp remains lit Operation is continuing but there may be a problem with the system In this case you should note down the error code and then call your dealer or servicer for advice...

Страница 12: ...imum minimum 3 Mode selection MODE SELEC TION 1 Remote controller main sub setting CONTROLLER MAIN SUB Selecting main or sub remote controller When 2 remote controllers are connected to 1 group 1 controller must be set to sub 2 Use of clock setting CLOCK Setting the use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting the timer type 4 Contact number setting for error situ...

Страница 13: ...de is displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initial setting value The temperature range can be changed on cooling dry mode The temperature range can be changed on heating mode The temperature range can be changed on automatic mode The remote controller wil...

Страница 14: ...the lower limit setting press the button The selected setting will blink and the tem perature can be set Settable range Cooling Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heating mode Lower limit 17 C 28 C Upper limit 28 C 17 C Automatic mode Lower limit 19 C 28 C Upper limit 28 C 19 C 8 Function Selection 4 3 Mode selection setting 1 Remote controller main sub setting To switch the sett...

Страница 15: ...ture cooling day mode Limit temperature heating mode Limit temperature auto mode Mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of the week and time Timer set Timer monitor Weekly timer Timer mode off Auto off timer Simple timer Contact number setting of error situation Display change Temperature display C F setting Room air tempera...

Страница 16: ...u do not have a vacuum clean er tap the filters against a solid object to knock off dirt and dust If the filters are especially dirty wash them in lukewarm water Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit Caution Do not dry the filters in direct sunlight or by using a heat source such as an electric heater this may war...

Страница 17: ...condition may occur when operation starts During defrosting mode cool airflow may blow down and appear like a mist Water or vapor is emitted from the outdoor unit During cooling mode water may form and drip from the cool pipes and joints During heating mode water may form and drip from the heat exchang er During defrosting mode water on the heat exchanger evaporates and water vapor may be emitted T...

Страница 18: ...lose The batteries are low Replace the batteries and press the Reset button If nothing appears even after the batteries are replaced make sure that the batteries are installed in the correct directions The operation lamp near the receiver for the wireless remote controller on the indoor unit is blinking The self diagnosis function has operated to protect the air conditioner Do not attempt to repai...

Страница 19: ...inted in PRC RG79D719H04 HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Please be sure to put the contact address telephone number on this manual before handing it to the customer ...

Отзывы: