Mitsubishi Electric Mr.SLIM PCA-RP KAQ Скачать руководство пользователя страница 14

14

[Detailed setting]

[4]-1 CHANGE LANGUAGE setting
    The language that appears on the dot display can be selected.
  • Press 

the 

[   MENU] button 

 to change the language.

     

 English (GB), 

 German (D), 

 Spanish (E), 

 Russian (RU),

     

 Italian (I), 

 Chinese (CH), 

 French (F), 

 Japanese (JP)

    Refer to the dot display table.

[4]-2 Function limit
  (1)  Operation function limit setting (operation lock)
  •  

To switch the setting, press the [   ON/OFF] button 

.

     

 no1:  Operation lock setting is made on all buttons other than 

the [ 

 ON/OFF] button 

.

     

  no2: Operation lock setting is made on all buttons.

     

  OFF (Initial setting value): Operation lock setting is not made.

  *  

To make the operation lock setting valid on the normal screen, it 
is necessary to press buttons (Press and hold down the [FILTER]  

and [

 ON/OFF] buttons 

at the same time for 2 seconds.) 

on the normal screen after the above setting is made.

  (2)  Use of automatic mode setting
     When the remote controller is connected to the unit that has auto-

matic operation mode, the following settings can be made.

    •  To switch the setting, press the [   ON/OFF] button 

.

     

  ON (Initial setting value):

         The automatic mode is displayed when the operation mode is 

selected.

     

 OFF:

         The automatic mode is not displayed when the operation mode 

is selected

.
  (3)  Temperature range limit setting
     After this setting is made, the temperature can be changed within 

the set range.

    •  To switch the setting, press the [   ON/OFF] button 

.

     

 LIMIT TEMP COOL MODE:

        The temperature range can be changed on cooling/dry mode.
     

 LIMIT TEMP HEAT MODE:

        The temperature range can be changed on heating mode.
     

 LIMIT TEMP AUTO MODE:

        The temperature range can be changed on automatic mode.
     

 OFF (initial setting): The temperature range limit is not active.

      *   When the setting other than OFF is made, the temperature 

range limit setting on cooling, heating and automatic mode is 
made at the same time. However, the range cannot be limited 
when the set temperature range has not changed.

  •  

To increase or decrease the temperature, press the [   TEMP.

      ( ) or ( )] button 

.

  •  

To switch the upper limit setting and the lower limit setting, press 
the [

] button 

. The selected setting will blink and the tem-

perature can be set.

  • Settable 

range

   Cooling/Dry 

mode:

        Lower limit:19°C - 30°C 

Upper limit:30°C - 19°C

   Heating 

mode:

        Lower limit:17°C - 28°C 

Upper limit:28°C - 17°C

   Automatic 

mode:

        Lower limit:19°C - 28°C 

Upper limit:28°C - 19°C

8. Function Selection

[4]-3 Mode selection setting

  (1)  Remote controller main/sub setting
    •  To switch the setting, press the [   ON/OFF] button 

.

     

 Main: 

The controller will be the main controller.

     

 Sub: 

The controller will be the sub controller.

  (2)  Use of clock setting
    •  To switch the setting, press the [   ON/OFF] button 

.

     

 ON: 

The clock function can be used.

     

 OFF: 

The clock function cannot be used.

  (3)  Timer function setting
  •  

To switch the setting, press the [   ON/OFF] button 

 (Choose 

one of the followings.).

     

 WEEKLY TIMER (initial setting value):

        The weekly timer can be used.
     

 AUTO OFF TIMER:

        The auto off timer can be used.
     

 SIMPLE TIMER:

        The simple timer can be used.
     

 TIMER MODE OFF:

        The timer mode cannot be used.
  *  

When the use of clock setting is OFF, the “WEEKLY TIMER” can-
not be used.

  (4)  Contact number setting for error situation
    •  To switch the setting, press the [   ON/OFF] button 

.

     

 CALL OFF:

        The set contact numbers are not displayed in case of error.
     

 CALL **** *** ****:

        The set contact numbers are displayed in case of error.
    CALL_:
         The contact number can be set when the display is as shown 

above.

    •  Setting the contact numbers
        To set the contact numbers, follow the following procedures.
         Move the blinking cursor to set numbers. Press the [   TEMP. 

( ) and ( )] button 

 to move the cursor to the right (left). 

Press the [   CLOCK ( ) and ( )] button 

 to set the num-

bers.

[4]-4 Display change setting
  (1)  Temperature display °C/°F setting
    •  To switch the setting, press the [   ON/OFF] button 

.

     

 °C: 

The temperature unit °C is used.

     

 °F: 

The temperature unit °F is used.

  (2)  Room air temperature display setting
    •  To switch the setting, press the [   ON/OFF] button 

.

     

 ON: 

The room air temperature is displayed.

     

 OFF: 

The room air temperature is not displayed.

  (3)  Automatic cooling/heating display setting
    •  To switch the setting, press the [   ON/OFF] button 

.

     

 ON:

         One of “Automatic cooling” or “Automatic heating” is displayed 

under the automatic mode is running.

     

 OFF:

         Only “Automatic” is displayed under the automatic mode.

Содержание Mr.SLIM PCA-RP KAQ

Страница 1: ...o correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används Français Deutsch English Nederlands Español Italiano Português Dans...

Страница 2: ... for EU countries only This symbol mark is according to the directive 2002 96 EC Article 10 Information for users and Annex IV and or to the directive 2006 66 EC Article 20 Information for end users and Annex II Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and or reused This symbol means that electrical and electroni...

Страница 3: ... The indicator shows the direc tion of the outcoming airflow Day of Week Shows the current day of the week Room Temperature display Shows the room temperature The room temperature display range is 8 39 C The display blinks if the temperature is less than 8 C or 39 C or more Time Timer Display Shows the current time unless the simple or Auto Off timer is set If the simple or Auto Off timer is set sh...

Страница 4: ...ndoor Outdoor Connection wire Ref Pipes Indoor Unit PSA RP KA Fan speed 3 speeds Auto Vane Manual Louver Auto with swing Filter Long life Filter cleaning indication 2 500 hr PSA RP KA Floor Standing Air intake Filter Air outlet Vane Louver Remote controller ...

Страница 5: ...ton as necessary to set the time As you hold the button down the time at will increment first in one minute intervals then in ten minute intervals and then in 1 hour intervals 4 After making the appropriate settings at Steps 2 and 3 press the Filter button to lock in the values 5 Operation F C TIMER MON OFF WEEKLY SUN MON TUE WED THU FRI SAT WEEKLY F C C TIME SUN Function Selection of remote contro...

Страница 6: ...inutes the air conditioner switches to cooling mode In the same way if the room temperature remains 2 C or more below the set temperature for 15 minutes the air conditioner switches to heating mode Because the room temperature is automatically adjusted in order to maintain a fixed effective temperature cooling operation is performed a few degrees warmer and heating operation is performed a few de g...

Страница 7: ...ing operation the arrow display move to the left and right Low High 6 Timer 6 1 For Wired Remote controller You can use Function Selection of remote controller to select which of 3 types of timer to use Weekly timer Simple timer or Auto Off timer 6 1 1 Weekly Timer The weekly timer can be used to set up to 8 operations for each day of the week Each operation may consist of any of the following ON ...

Страница 8: ...you have set 2 or more different operations for exactly the same time only the operation with the highest Operation No will be carried out 9 Repeat Steps 3 to 8 as necessary to fill as many of the available cells as you wish 10 Press the mode Return button to return to the standard control screen and complete the setting procedure 11 To activate the timer press the Timer On Off button so that the T...

Страница 9: ... OFF indication appears at ON timer The air conditioner will start operation when the specified number of hours has elapsed OFF timer The air conditioner will stop operation when the specified number of hours has elapsed Timer Setting TIMER ON OFF Hr AFTER SIMPLE C C SIMPLE 1 Be sure that the simple timer indicator is visible on the screen at 2 Press the Timer Menu button so that the Monitor appears...

Страница 10: ...of the following conditions is in effect The timer is off the system is in malfunction state a test run is in prog ress the remote controller is undergoing self check or remote control ler check the user is in the process of selecting a function the user is in the process of setting the timer the system is under central control Under these conditions On Off operation is prohibited AFTER OFF AUTO O...

Страница 11: ...s as described above C C TIME SUN FUNCTION ON OFF TEMP CLEAR If you press a locked button the Locked indication at will blink on the display C C FUNCTION C C FUNCTION C C If only the error code is blinking while the ON lamp remains lit Operation is continuing but there may be a problem with the system In this case you should note down the error code and then call your dealer or servicer for advice...

Страница 12: ...imum minimum 3 Mode selection MODE SELEC TION 1 Remote controller main sub setting CONTROLLER MAIN SUB Selecting main or sub remote controller When 2 remote controllers are connected to 1 group 1 controller must be set to sub 2 Use of clock setting CLOCK Setting the use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting the timer type 4 Contact number setting for error situ...

Страница 13: ...de is displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initial setting value The temperature range can be changed on cooling dry mode The temperature range can be changed on heating mode The temperature range can be changed on automatic mode The remote controller wil...

Страница 14: ...the lower limit setting press the button The selected setting will blink and the tem perature can be set Settable range Cooling Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heating mode Lower limit 17 C 28 C Upper limit 28 C 17 C Automatic mode Lower limit 19 C 28 C Upper limit 28 C 19 C 8 Function Selection 4 3 Mode selection setting 1 Remote controller main sub setting To switch the sett...

Страница 15: ...ture cooling day mode Limit temperature heating mode Limit temperature auto mode Mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of the week and time Timer set Timer monitor Weekly timer Timer mode off Auto off timer Simple timer Contact number setting of error situation Display change Temperature display C F setting Room air tempera...

Страница 16: ...u do not have a vacuum clean er tap the filters against a solid object to knock off dirt and dust If the filters are especially dirty wash them in lukewarm water Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit Caution Do not dry the filters in direct sunlight or by using a heat source such as an electric heater this may war...

Страница 17: ...condition may occur when operation starts During defrosting mode cool airflow may blow down and appear like a mist Water or vapor is emitted from the outdoor unit During cooling mode water may form and drip from the cool pipes and joints During heating mode water may form and drip from the heat exchang er During defrosting mode water on the heat exchanger evaporates and water vapor may be emitted T...

Страница 18: ...lose The batteries are low Replace the batteries and press the Reset button If nothing appears even after the batteries are replaced make sure that the batteries are installed in the correct directions The operation lamp near the receiver for the wireless remote controller on the indoor unit is blinking The self diagnosis function has operated to protect the air conditioner Do not attempt to repai...

Страница 19: ...inted in PRC RG79D719H04 HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Please be sure to put the contact address telephone number on this manual before handing it to the customer ...