Having trouble?

Air conditioner does not heat or cool well.

When heating operation starts, warm air does not blow from the indoor unit
soon.

During heating mode, the air conditioner stops before the set room tem-
perature is reached.

Airflow direction changes during operation or airflow direction cannot be
set.

When the airflow direction is changed, the vanes always move up and down
past the set position before finally stopping at the position.

A flowing water sound or occasional hissing sound is heard.

A cracking or creaking sound is heard.

The room has an unpleasant odor.

A white mist or vapor is emitted from the indoor unit.

Water or vapor is emitted from the outdoor unit.

The operation indicator does not appear in the remote controller display.

Here is the solution. (Unit is operating normally.)

Clean the filter. (Airflow is reduced when the filter is dirty or clogged.)

Check the temperature adjustment and adjust the set temperature.

Make sure that there is plenty of space around the outdoor unit. Is the
indoor unit air intake or outlet blocked?

Has a door or window been left open?

Warm air does not blow until the indoor unit has sufficiently warmed up.

When the outdoor temperature is low and the humidity is high, frost may
form on the outdoor unit. If this occurs, the outdoor unit performs a de-
frosting operation. Normal operation should begin after approximately 10
minutes.

During cooling mode, the vanes automatically move to the horizontal
(down) position after 1 hour when the down (horizontal) airflow direction
is selected. This is to prevent water from forming and dripping from the
vanes.

During heating mode, the vanes automatically move to the horizontal
airflow direction when the airflow temperature is low or during defrosting
mode.

When the airflow direction is changed, the vanes move to the set position
after detecting the base position.

These sounds can be heard when refrigerant is flowing in the air condi-
tioner or when the refrigerant flow is changing.

These sounds can be heard when parts rub against each due to expan-
sion and contraction from temperature changes.

The indoor unit draws in air that contains gases produced from the walls,
carpeting, and furniture as well as odors trapped in clothing, and then
blows this air back into the room.

If the indoor temperature and the humidity are high, this condition may
occur when operation starts.

During defrosting mode, cool airflow may blow down and appear like a
mist.

During cooling mode, water may form and drip from the cool pipes and
joints.

During heating mode, water may form and drip from the heat exchanger.

During defrosting mode, water on the heat exchanger evaporates and
water vapor may be emitted.

Turn on the power switch. “ ” will appear in the remote controller display.

11. Trouble  Shooting

C

Emergency operation switch (heating)

D

Emergency operation switch (cooling)

E

Receiver

Starting operation
• To operate the cooling mode, press the 

 button 

D

.

• To operate the heating mode, press the 

 button 

C

.

Note:
• Details of emergency mode are as shown below.

Details of EMERGENCY MODE are as shown below.

Operation mode

COOL

HEAT

Set temperature

24°C, 75°F

24°C, 75°F

Fan speed

High

High

Airflow direction

Horizontal

Downward 4

Stopping operation
• To stop operation, press the 

 button 

D

 or the 

 button 

C

.

9. Emergency Operation for Wireless Remote-controller

ON

OFF

STAND

BY

COOL HEAT

B

E

D

C

A

When the remote controller cannot be used

When the batteries of the remote controller run out or the remote controller
malfunctions, the emergency operation can be done using the emergency
buttons on the grille.

A

DEFROST/STAND BY lamp

B

Operation lamp

ON/OFF 

TEMP.

˚F

˚F

FILTER

Indicates that the filter needs cleaning.
Ask authorized people to clean the filter.

When resetting “FILTER” display
When the [FILTER] button is pressed two times successively after
cleaning the filter, the display goes off and is reset.

10. Care and Cleaning

Note:

When two or more different types of indoor unit are controlled, the cleaning
period differs with the type of filter. When the master unit cleaning period
arrives, “FILTER” is displayed. When the filter display goes off, the cumula-
tive time is reset.

“FILTER” indicates the cleaning period when the air conditioner was used
under general indoor air conditions by criteria time. Since the degree of dirti-
ness depends on the environmental conditions, clean the filter accordingly.

The filter cleaning period cumulative time differs with the model.

This indication is not available for wireless remote controller.

 BG79U794H02_en

05.12.22, 2:02 PM

16

Содержание Mr.Slim PCA-A-GA

Страница 1: ...condicionado para garantizar un uso seguro y correcto OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit FOR USER PARA EL USUARIO Deutsch Nederlands Español Italiano ÏÏËÓÈÎ Português Dansk Svenska English Español PLA A AA PKA A GA PKA A GAL PKA A FA PKA A FAL PCA A GA ...

Страница 2: ...ot remove the front panel or the fan guard from the outdoor unit when it is running When you notice exceptionally abnormal noise or vibration stop operation turn off the power switch and contact your dealer Never insert fingers sticks etc into the intakes or outlets If you detect odd smells stop using the unit turn off the power switch and consult your dealer Otherwise a breakdown electric shock o...

Страница 3: ... Air outlet PCA A GA Ceiling Suspended PKA A GA PKA A GAL Wall Mounted PKA A FA PKA A FAL Wall Mounted Filter Air intake Louver Air outlet Vane Air intake Filter Louver Air outlet Vane Filter Air intake Louver Air outlet Vane Filter Air intake Vane ...

Страница 4: ...e hour at which time the airflow di rection also changes Room Temperature display Showstheroomtemperature Theroom temperature display range is 8 39 C The display flashes if the temperature is less than 8 C or 39 C or more Louver display Indicates the action of the swing louver Does not appear if the louver is station ary Power On indicator Indicates that the power is on Fan Speed indicator Shows t...

Страница 5: ...7 meters in a direct line from the indoor unit in an area 45 to the left and right of the unit However illumination such as fluorescent lights and strong light can affect the ability of the indoor unit to receive signals If the operation lamp near the receiver on the indoor unit is flashing the unit needs to be inspected Consult your dealer for service Handle the remote controller carefully Do not...

Страница 6: ...ting Horiz outlet 1 2 6 5 3 7 5 1 Turning ON OFF To Start Operation Press the ON OFF button 1 The ON lamp and the display area come on Note When the unit is restarted initial settings are as follows Screen Types For details on setting the language for the remote controller display refer to section 8 Function Selection The initial language setting is English Function Selection of remote controller ...

Страница 7: ...set the desired temperature The selected temperature is displayed Available temperature ranges are as follows Cooling Drying 19 30 C 67 87 F Heating 17 28 C 63 83 F Automatic 19 28 C 67 83 F The display flashes either 8 C 39 C 46 F 102 F to inform you if the room temperature is lower or higher than the displayed temperature 5 4 Fan speed setting Press the Fan Speed button 5 as many times as necess...

Страница 8: ...and 4 will select one of the cells from the matrix illustrated below The remote controller display at left shows how the display would appear when setting Operation 1 for Sunday to the values indicated below 6 Timer 5 Operation Low High To Change the Right Left Air Direction Press the louver button 7 as necessary The louver image appears Each press of the button switches the setting as follows ON ...

Страница 9: ...lear button 0 so that the time setting clears to at If you want to use only an ON setting or only an OFF setting be sure that the setting you do not wish to use is shown as Timer Settings F TIMER SUN ON OFF WEEKLY ª F F TIME SUN WEEKLY 10 F F TIME SUN WEEKLY 10 6 Timer 7 Press the appropriate Set Temperature button 3 to set the desired temperature at Each press changes the setting in the following...

Страница 10: ...ing 5 hours OFF setting 2 hours 3 hours At Timer Start Display shows the timer s OFF setting hours remaining to OFF At 5 hours after timer start The air conditioner comes on and will continue to run until someone turns it off 6 1 3 Auto Off Timer This timer begins countdown when the air conditioner starts and shuts the air conditioner off when the set time has elapsed Available settings run from 3...

Страница 11: ...ote controller during timer mode to stop the unit will cancel the timers If the current time has not been set the timer operation cannot be used 7 Other Functions F F TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF 4 1 Lock Indicator 7 1 Locking the Remote Controller Buttons Operation function limit controller If you wish you can loc...

Страница 12: ...selection mode Change the setting when needed Item 1 1 Change Language CHANGE LANGUAGE 2 Function limit FUNCTION SELECTION 3 Mode selection MODE SELEC TION 4 Display change DISP MODE SETTING Item 2 Language setting to display 1 Operation function limit setting operation lock LOCKING FUNCTION 2 Use of automatic mode setting SELECT AUTO MODE 3 Temperature range limit setting LIMIT TEMP FUNCTION 1 Re...

Страница 13: ...ection Display mode setting 8 Function Selection Operation lock setting is not used Initial setting value Operation lock setting is except On Off button Operation lock setting is All buttons The automatic mode is displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initi...

Страница 14: ...utton H The selected setting will flash and the temperature can be set Settable range Cooling Dry mode Lower limit 19 C 30 C 67 F 87 F Upper limit 30 C 19 C 87 F 67 F Heating mode Lower limit 17 C 28 C 63 F 83 F Upper limit 28 C 17 C 83 F 63 F Automatic mode Lower limit 19 C 28 C 67 F 83 F Upper limit 28 C 19 C 83 F 67 F 4 3 Mode selection setting 1 Remote controller main sub setting To switch the...

Страница 15: ...ature cooling day mode Limit temperature heating mode Limit temperature auto mode Mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of the week and time Timer set Timer monitor Weekly timer Timer mode off Auto off timer Simple timer Contact number setting of error situation Display change Temperature display C F setting Room air temper...

Страница 16: ... produced from the walls carpeting and furniture as well as odors trapped in clothing and then blows this air back into the room If the indoor temperature and the humidity are high this condition may occur when operation starts During defrosting mode cool airflow may blow down and appear like a mist During cooling mode water may form and drip from the cool pipes and joints During heating mode wate...

Страница 17: ... the ON OFF button to restart operation Is the air conditioner connected to a central remote controller Consult the concerned people who control the air conditioner Does appear in the remote controller display Consult the concerned people who control the air conditioner Are timer settings invalid If the timer can be set WEEKLY SIMPLE or AUTO OFF appears in the remote controller display The initial...

Страница 18: ...8 230 60 0 33 0 43 0 52 1 1 1 1 1 15 15 15 15 15 13 3 8 13 3 8 39 55 1 8 66 1 8 9 1 4 9 1 4 320 350 390 425 530 705 780 990 290 315 350 380 480 635 700 890 36 38 41 43 39 45 46 49 35 53 62 Model Power source Phase Voltage V Frequency Hz Fan motor FLA MCA A MOCP A Dimension Height inch Dimension Width inch Dimension Depth inch Airflow DRY CFM Low Middle2 Middle1 High WET CFM Noise level Low Middle2...

Страница 19: ......

Страница 20: ... el panel frontal del ventilador de la unidad exterior mien tras esté en funcionamiento Cuando note ruidos o vibraciones que no sean normales pare la unidad desconecte la fuente de alimentación y póngase en con tacto con su proveedor No inserte nunca dedos palos etc en las tomas o salidas de aire Si detecta olores raros pare la unidad desconecte el interruptor de red y consulte con su distribuidor...

Страница 21: ...elo montado en techo PKA A GA PKA A GAL Modelo montado en pared PKA A FA PKA A FAL Modelo montado en pared Filtro Entrada de aire Rejilla Deflector Entrada de aire Filtro Rejilla Deflector Filtro Entrada de aire Rejilla Deflector Filtro Entrada de aire Deflector Salida de aire Salida de aire Salida de aire ...

Страница 22: ...o auto mático en cuyo caso muestra el tiempo restante Indicador Sensor Aparece cuando se utiliza el sensor del mando a distancia Indicador Locked Indica que se han bloqueado los boto nes del mando a distancia Indicador Clean The Filter Se enciende cuando debe limpiarse el filtro Indicadores del temporizador El indicador se enciende si se ha con figurado el temporizador correspon diente Indicador d...

Страница 23: ...de recibir señales emitidas a un máximo de 7 metros en línea recta en un rango de 45 a derecha e izquierda de la unidad Sin embargo ciertos sistemas de iluminación con fluorescentes o luces fuertes pueden afectar a la capacidad de recepción de señal de la unidad interior Si la luz de funcionamiento situada cerca del receptor de la unidad interior parpadea será necesario inspeccionar la unidad Cons...

Страница 24: ...encienden la lámpara de encendido y la pantalla Nota Cuando se reinicia la unidad las configuraciones iniciales son las siguientes Tipos de pantallas El ajuste de idioma de la pantalla se puede cambiar a español utilizando la selección de función del controlador remoto Consulte la sección 8 punto 4 1 para cambiar el ajuste de idioma El ajuste inicial es inglés Selección de Función configure las fu...

Страница 25: ...isor aparecerá la temperatura seleccionada Las gamas de ajuste de temperaturas disponibles son las siguientes Enfriamiento y secado 19 30 C 67 87 F Calefacción 17 28 C 63 83 F Automático 19 28 C 67 83 F La pantalla parpadea 8 C 39 C 46 F 102 F para informar si la temperatura de la habitación es inferior o superior a la temperatura que se visualiza 5 4 Ajuste de la velocidad del ventilador Pulse el...

Страница 26: ...ionará una de las celdas de la matriz ilustrada a continuación La pantalla del mando a distancia en la izquierda muestra cómo se mostraría la pantalla cuando se configura Operación 1 para el do mingo con los valores indicados a continuación 6 Temporizador 5 Manejo Para cambiar la dirección del aire Derecha Izquierda Pulse el botón Louver 7 según sea necesario Aparece la imagen de la rejilla Cada p...

Страница 27: ...o o apagado véase el paso 3 y luego pulse el botón Check Clear 0 para borrar la configuración de la hora a en Si desea utilizar sólo un valor de configuración de encendido o una configuración de apagado asegúrese de que la configuración que no desea utilizar se muestra como Valores fijados del temporizador F TIMER SUN ON OFF WEEKLY ª F F TIME SUN WEEKLY 10 F F TIME SUN WEEKLY 10 6 Temporizador 7 P...

Страница 28: ...oras Al inicio del temporizador La pantalla muestra el valor de apagado del temporizador las horas restantes para el apa gado 5 horas después del inicio del temporizador El acondicionador de aire comienza a funcionar y continuaráfuncionandohastaquealguienlodetenga 6 1 3 Temporizador de apagado automático Este temporizador comienza la cuenta atrás cuando el acondicionador de aire comienza a funcion...

Страница 29: ... ON OFF del mando a distancia durante el modo de temporizador para parar la unidad se cancelarán los temporizadores Si no ha ajustado la hora actual no podrá utilizar la función del temporizador 7 Otras funciones F F TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF 4 1 7 1 Bloqueo de los botones del mando a distancia lí mite de funció...

Страница 30: ...Pantalla alternante Lámpara ON parpadeando Ítem 1 1 Cambio de idioma CHANGE LANGUAGE 2 Límite de funciones SELECCIÓN DE FUNCIÓNES 3 Selección de modo SELECCIÓN DE MODO 4 Cambio de indicador MOSTRAR MODO Ítem 2 Ajuste del idioma que aparece en el indicador 1 Ajuste del límite de funciones bloqueo de funciones FUN CIÓN BLOQUEADA 2 Uso del ajuste de modo automático SELECCIÓN MODO AUTO 3 Ajuste del lí...

Страница 31: ...e función El ajuste de función bloqueada no se utiliza valor de ajuste inicial El bloqueo de funcionamiento está ajustado excepto para los botón On Off encendido y apagado El bloqueo de funcionamiento está ajustado para todos los botones El modo automático aparece al seleccionar el modo de funcionamien to valor de ajuste inicial El modo automático no aparece al seleccionar el modo de funciona mien...

Страница 32: ...ración Secado Límite inferior 19 C a 30 C 67 F a 87 F Límite superior 30 C a 19 C 87 F a 67 F Modo Calefacción Límite inferior 17 C a 28 C 63 F a 83 F Límite superior 28 C a 17 C 83 F a 63 F Modo Automático Límite inferior 19 C a 28 C 67 F a 83 F Límite superior 28 C a 19 C 83 F a 67 F 4 3 Ajuste de selección de modo 1 Ajuste del controlador remoto principal secundario Para cambiar el ajuste presi...

Страница 33: ... MAIN PRINCIPAL Ajuste de controlador remoto SUB SECUNDARIO Utilización del ajuste del reloj Ajuste del día de la semana y la hora Ajuste del temporizador Visualización del temporizador Temporizador semanal Modo de temporizador apagado Temporizador de apagado automá tico Temporizador simple Ajuste de número de contacto en caso de avería Cambio de indicación Ajuste de visualización de tempe ratura ...

Страница 34: ...e se mueven arriba y abajo antes de detenerse en la posición ajustada Se oye un sonido de agua fluyendo o en ocasiones una especie de silbi do Se oye un traqueteo o un chirrido Hay un olor desagradable en la sala La unidad interior expulsa un vaho o humo blanco La unidad exterior expulsa agua o vapor El indicador de operación no aparece en la pantalla del controlador remoto Aquí tiene la solución ...

Страница 35: ...do el temporizador de apagado Pulse el botón ON OFF ENCENDIDO APAGADO para reiniciar el fun cionamiento El acondicionador de aire está conectado a un controlador remoto central Consulte a la persona encargada de controlar el acondicionador de aire Aparece en la pantalla del controlador remoto Consulte a la persona encargada de controlar el acondicionador de aire Los ajustes del temporizador no son...

Страница 36: ...FA Monofase 208 230 60 0 33 0 43 0 52 1 1 1 1 1 15 15 15 15 15 13 3 8 13 3 8 39 55 1 8 66 1 8 9 1 4 9 1 4 320 350 390 425 530 705 780 990 290 315 350 380 480 635 700 890 36 38 41 43 39 45 46 49 35 53 62 Modelo Alimentación Fase Voltaje V Frecuencia Hz Motor del ventilador FLA MCA A MOCP A Dimensión altura inch Dimensión ancho inch Dimensión profundidad inch Flujo de aire DRY CFM Bajo Media 2 Media...

Страница 37: ...3400 Lawrenceville Suwanee Road Suwanee Georgia 30024 Toll Free 800 433 4822 Toll Free Fax 800 889 9904 www mrslim com Specifications are subject to change without notice ...

Отзывы: