1. BEFORE INSTALLATION
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
• Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.
%HVXUHWRREVHUYHWKHZDUQLQJVDQGFDXWLRQVVSHFL¿HGKHUHDVWKH\LQFOXGHLPSRUWDQWLWHPVUHODWHGWRVDIHW\
• After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.
1-3. SPECIFICATIONS
CAUTION
&RXOGOHDGWRVHULRXVLQMXU\LQSDUWLFXODUHQYLURQPHQWVZKHQRSHUDWHGLQFRUUHFWO\
N
Do not install the unit by yourself (user).
,QFRPSOHWHLQVWDOODWLRQFRXOGFDXVH¿UHRUHOHFWULFVKRFNLQMXU\GXHWRWKH
XQLWIDOOLQJRUOHDNDJHRIZDWHU&RQVXOWWKHGHDOHUIURPZKRP\RXSXU
-
FKDVHGWKHXQLWRUDTXDOL¿HGLQVWDOOHU
N
Perform the installation securely referring to the installation manual.
,QFRPSOHWHLQVWDOODWLRQFRXOGFDXVH¿UHRUHOHFWULFVKRFNLQMXU\GXHWRWKH
unit falling, or leakage of water.
N
Install the unit securely in a place which can bear the weight of the
unit.
If the installation location cannot bear the weight of the unit, the unit
FRXOGIDOOFDXVLQJLQMXU\
N
Perform electrical work according to the installation manual and be
sure to use an exclusive circuit. Do not connect other electrical appli-
ances to the circuit.
,I WKH FDSDFLW\ RI WKH SRZHU FLUFXLW LV LQVXI¿FLHQW RU WKHUH LV LQFRPSOHWH
HOHFWULFDOZRUNLWFRXOGUHVXOWLQD¿UHRUDQHOHFWULFVKRFN
N
Do not damage the wires by applying excessive pressure with parts
or screws.
'DPDJHGZLUHVFRXOGFDXVH¿UH
N
Be sure to cut off the main power in case of setting up the indoor P.C.
board or wiring works.
Failure to do so could cause electric shock.
N
8VHWKHVSHFL¿HGZLUHVWRFRQQHFWWKHLQGRRUDQGRXWGRRUXQLWVVH
-
FXUHO\DQGDWWDFKWKHZLUHV¿UPO\WRWKHWHUPLQDOEORFNFRQQHFWLQJ
sections so the stress of the wires is not applied to the sections.
,QFRPSOHWHFRQQHFWLQJDQGVHFXULQJFRXOGFDXVH¿UH
N
'RQRWLQVWDOOWKHXQLWLQDSODFHZKHUHLQÀDPPDEOHJDVPD\OHDN
If gas leaks and accumulates in the area around the unit, it could cause
an explosion.
N
Do not use intermediate connection of the power cord or the exten-
sion cord and do not connect many devices to one AC outlet.
,WFRXOGFDXVHD¿UHRUDQHOHFWULFVKRFNGXHWRGHIHFWLYHFRQWDFWGHIHF
-
tive insulation, exceeding the permissible current, etc.
N
%HVXUHWRXVHWKHSDUWVSURYLGHGRUVSHFL¿HGSDUWVIRUWKHLQVWDOOD
-
tion work.
7KHXVHRIGHIHFWLYHSDUWVFRXOGFDXVHDQLQMXU\RUOHDNDJHRIZDWHUGXH
WRD¿UHDQHOHFWULFVKRFNWKHXQLWIDOOLQJHWF
N
When plugging the power supply plug into the outlet, make sure
that there is no dust, clogging, or loose parts in both the outlet and
the plug. Make sure that the power supply plug is pushed complete-
ly into the outlet.
,IWKHUHLVGXVWFORJJLQJRUORRVHSDUWVRQWKHSRZHUVXSSO\SOXJRUWKH
RXWOHWLWFRXOGFDXVHHOHFWULFVKRFNRU¿UH,IORRVHSDUWVDUHIRXQGRQWKH
SRZHUVXSSO\SOXJUHSODFHLW
N
Attach the electrical cover to the indoor unit and the service panel
to the outdoor unit securely.
If the electrical cover of the indoor unit and/or the service panel of the
RXWGRRU XQLW DUH QRW DWWDFKHG VHFXUHO\ LW FRXOG UHVXOW LQ D ¿UH RU DQ
electric shock due to dust, water, etc.
N
When installing or relocating the unit, make sure that no sub-
VWDQFHRWKHUWKDQWKHVSHFL¿HGUHIULJHUDQW5$HQWHUVWKH
refrigerant circuit.
$Q\ SUHVHQFH RI IRUHLJQ VXEVWDQFH VXFK DV DLU FDQ FDXVH DEQRUPDO
pressure rise or an explosion.
N
Do not discharge the refrigerant into the atmosphere. If refrigerant
leaks during installation, ventilate the room.
,IUHIULJHUDQWFRPHVLQFRQWDFWZLWKD¿UHKDUPIXOJDVFRXOGEHJHQHU
-
ated.
N
Check that the refrigerant gas does not leak after installation has
been completed.
,IUHIULJHUDQWJDVOHDNVLQGRRUVDQGFRPHVLQWRFRQWDFWZLWKWKHÀDPH
of a fan heater, space heater, stove, etc., harmful substances will be
generated.
N
Use appropriate tools and piping materials for installation.
The pressure of R410A is 1.6 times more than R22. Not using appropri-
ate tools or materials and incomplete installation could cause the pipes
WREXUVWRULQMXU\
N
When pumping down the refrigerant, stop the compressor before
disconnecting the refrigerant pipes.
If the refrigerant pipes are disconnected while the compressor is run-
ning and the stop valve is open, air could be drawn in and the pressure
LQ WKH UHIULJHUDWLRQ F\FOH FRXOG EHFRPH DEQRUPDOO\ KLJK 7KLV FRXOG
FDXVHWKHSLSHVWREXUVWRULQMXU\
N
When installing the unit, securely connect the refrigerant pipes
before starting the compressor.
If the compressor is started before the refrigerant pipes are connected
and when the stop valve is open, air could be drawn in and the pres-
VXUH LQ WKH UHIULJHUDWLRQ F\FOH FRXOG EHFRPH DEQRUPDOO\ KLJK 7KLV
FRXOGFDXVHWKHSLSHVWREXUVWRULQMXU\
N
)DVWHQDÀDUHQXWZLWKDWRUTXHZUHQFKDVVSHFL¿HGLQWKLV
manual.
,IIDVWHQHGWRRWLJKWDÀDUHQXWPD\EUHDNDIWHUDORQJSHULRGDQGFDXVH
refrigerant leakage.
N
The unit shall be installed in accordance with national wiring regu-
lations.
N
Ground the unit correctly.
Do not connect the ground to a gas pipe, water pipe, lightning rod or
telephone ground. Defective grounding could cause electric shock.
N
Install an ground leakage breaker depending on the installation place.
If an ground leakage breaker is not installed, it could cause electric shock.
N
Perform the drainage/piping work securely according to the installa-
tion manual.
If there is defect in the drainage/piping work, water could drop from the
unit, soaking and damaging household goods.
N
'RQRWWRXFKWKHDLULQOHWRUWKHDOXPLQXP¿QVRIWKHRXWGRRU
unit.
7KLVFRXOGFDXVHLQMXU\
N
Do not install the outdoor unit where small animals may live.
If small animals enter and touch the electric parts inside the unit, it
FRXOGFDXVHDPDOIXQFWLRQVPRNHHPLVVLRQRU¿UH$OVRDGYLVHXVHU
to keep the area around the unit clean.
Model
3RZHUVXSSO\
Pipe length and height difference *2, *3, *4, *8
Rated
Voltage
)UHTXHQF\
Max. pipe length per indoor
XQLWIRUPXOWLV\VWHP
Max.
height difference
Max. no. of bends per in-
GRRUXQLWIRUPXOWLV\VWHP
Refrigerant adjustment A
*5
MXZ-2B20NA
208/
230 V
60 Hz
PIWPIW
PIW
25 / 50
JP
8
R]HDFKIW
WARNING
&RXOGOHDGWRGHDWKVHULRXVLQMXU\HWF
Phillips screwdriver
Level
Scale
8WLOLW\NQLIHRUVFLVVRUV
Torque wrench
:UHQFKRUVSDQQHU
PPLQKH[DJRQDOZUHQFK
Flare tool for R410A
Gauge manifold for R410A
Vacuum pump for R410A
Charge hose for R410A
Pipe cutter with reamer
1-2. REQUIRED TOOLS FOR INSTALLATION
1HYHU XVH SLSHV ZLWK WKLFNQHVV OHVV WKDQ VSHFL¿HG 7KH SUHVVXUH UHVLVW
-
DQFHZLOOEHLQVXI¿FLHQW
8VHDFRSSHUSLSHRUDFRSSHUDOOR\VHDPOHVVSLSH
*3 Be careful not to crush or bend the pipe during pipe bending.
5HIULJHUDQWSLSHEHQGLQJUDGLXVPXVWEHPPLQRUPRUH
,ISLSHOHQJWKH[FHHGVPIWDGGLWLRQDOUHIULJHUDQW5$FKDUJH
is required. (No additional charge is required for pipe length less than
PIW
$GGLWLRQDOUHIULJHUDQWP $îSLSHOHQJWKP
$GGLWLRQDOUHIULJHUDQWIW $î
SLSHOHQJWKIW
5
,QVXODWLRQPHDWUHVLVWLQJIRDPSODVWLFVSHFL¿FJUDYLW\
%HVXUHWRXVHWKHLQVXODWLRQRIVSHFL¿HGWKLFNQHVV([FHVVLYHWKLFNQHVV
PD\ FDXVH LQFRUUHFW LQVWDOODWLRQ RI WKH LQGRRU XQLW DQG LQVXI¿FLHQW WKLFN
-
QHVVPD\FDXVHGHZGULSSDJH
*8 If the outdoor unit is installed higher than the indoor unit, max. height
GLIIHUHQFHLVUHGXFHGWRPIW