Max. Length
A
Max. Height
difference
B
Indoor
unit
Outdoor unit
MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
Model
Refrigerant piping: ft.
Piping size O.D: in.
Max. Length
A
Max. Height difference
B
Gas Liquid
MUZ-FE09NA
MUZ-FE12NA
65
40
3/8
1/4
MUZ-FE18NA
100
50
5/8
3/8
ADDITIONAL REFRIGERANT CHARGE (R410A: oz.)
NOTE
: Refrigerant piping exceeding 25 ft. requires additional refrigerant charge according to the calculation.
Model
Outdoor unit precharged
Refrigerant piping length (one way): ft.
25
30
40
50
60
65
MUZ-FE09NA
MUZ-FE12NA
2 lb. 9 oz.
0
1.62
4.86
8.10
11.34
12.96
Calculation: X oz. = 1.08/5 oz. / ft. × (Refrigerant piping length (ft.) - 25)
NOTE
: Refrigerant piping exceeding 33 ft. requires additional refrigerant charge according to the calculation.
Model
Outdoor unit
precharged
Refrigerant piping length (one way): ft.
33
40
50
60
70
80
90
100
MUZ-FE18NA
4 lb. 3 oz.
0
4.14
10.06
15.98
21.90
27.82
33.74
39.66
Calculation: X oz. = 2.96/5 oz. / ft. × (Refrigerant piping length (ft.) - 33)