9
DATA
7
MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA
7-1. PERFORMANCE DATA
1) COOLING CAPACITY
Model
Indoor air
Outdoor intake air DB temperature (
˚
F)
IWB (
˚
F)
75
85
95
105
115
TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC
MUZ-FE09NA
71
11.0
6.9
0.58 10.3
6.5
0.63
9.7
6.1
0.68
9.0
5.6
0.72
8.3
5.2
0.75
67
10.4
7.9
0.55
9.7
7.4
0.60
9.0
6.8
0.65
8.4
6.4
0.69
7.7
5.8
0.72
63
9.8
8.8
0.52
9.1
8.1
0.58
8.5
7.6
0.62
7.7
6.9
0.66
7.0
6.3
0.69
MUZ-FE12NA
71
14.7
8.8
0.85 13.7
8.2
0.94 12.9
7.7
1.01 12.0
7.2
1.06 11.0
6.6
1.10
67
13.9 10.2 0.81 13.0
9.5
0.89 12.0
8.8
0.96 11.2
8.1
1.02 10.3
7.5
1.07
63
13.1 11.3 0.77 12.1 10.5 0.85 11.3
9.7
0.92 10.3
8.9
0.98
9.4
8.1
1.02
MUZ-FE18NA
71
22.1 15.6 1.13 20.6 14.6 1.24 19.4 13.7 1.33 18.0 12.7 1.40 16.6 11.7 1.46
67
20.9 17.5 1.07 19.4 16.3 1.17 18.0 15.1 1.27 16.7 14.1 1.35 15.4 12.9 1.41
63
19.6 19.1 1.02 18.2 17.7 1.12 16.9 16.5 1.21 15.4 15.0 1.30 14.0 13.7 1.35
NOTE
: 1. IWB : Intake air wet-bulb temperature
TC : Total Capacity (x10
3
Btu/h)
SHC : Sensible Heat Capacity (x10
3
Btu/h)
TPC : Total Power Consumption (kW)
2. SHC is based on 80
˚
F of indoor Intake air DB temperature.
2) COOLING CAPACITY CORRECTIONS
Refrigerant piping length (one way: ft.)
25 (std.)
40
65
100
MUZ-FE09NA
MUZ-FE12NA
1.0
0.954
0.878
-
MUZ-FE18NA
1.0
0.954
0.878
0.771
3) HEATING CAPACITY
Model
Indoor air
Outdoor intake air WB temperature (
˚
F)
IDB (
˚
F)
5
15
25
35
43
45
55
TC TPC TC TPC TC TPC TC TPC TC TPC TC TPC TC TPC
MUZ-FE09NA
75
4.8
0.44
6.3
0.56
7.9
0.66
9.4
0.73
10.6
0.77
11.0
0.78
12.4
0.81
70
5.2
0.42
6.7
0.54
8.2
0.64
9.6
0.71
10.9
0.75
11.2
0.77
12.7
0.80
65
5.5
0.41
6.9
0.52
8.6
0.62
10.0
0.69
11.2
0.73
11.6
0.74
13.0
0.78
MUZ-FE12NA
75
6.0
0.58
7.9
0.73
9.9
0.86
11.8
0.96
13.3
1.00
13.7
1.02
15.5
1.06
70
6.5
0.55
8.4
0.71
10.2
0.84
12.0
0.93
13.6
0.98
14.0
1.00
15.8
1.04
65
6.8
0.53
8.6
0.68
10.7
0.81
12.4
0.91
14.0
0.96
14.4
0.97
16.2
1.02
MUZ-FE18NA
75
9.5
0.91
12.5
1.15
15.7
1.35
18.7
1.50
21.1
1.58
21.7
1.60
24.6
1.66
70
10.3
0.87
13.3
1.11
16.2
1.32
19.1
1.46
21.6
1.54
22.2
1.57
25.2
1.63
65
10.8
0.83
13.6
1.06
17.0
1.27
19.8
1.42
22.2
1.50
22.9
1.52
25.7
1.60
NOTE
: 1. IDB : Intake air dry-bulb temperature
TC : Total Capacity (x10
3
Btu/h)
TPC : Total Power Consumption (kW)
2. Above data is for heating operation without any frost.
How to operate with fixed operational frequency of the compressor.
1. Press the EMERGENCY OPERATION switch on the front of the indoor unit, and select either EMERGENCY COOL
mode or EMERGENCY HEAT mode before starting to operate the air conditioner.
2. The compressor starts with operational frequency.
3. The fan speed of the indoor unit is High.
4. This operation continues for 30 minutes.
5. In order to release this operation, press the EMERGENCY OPERATION switch twice or once, or press any button on
the remote controller.