background image

En-1

● OPERATING INSTRUCTIONS ●

S

AFETY PRECAUTIONS

C

ONTENTS

 SAFETY PRECAUTIONS 

1

 NAME OF EACH PART 

3

 PREPARATION BEFORE OPERATION 

4

 SELECTING OPERATION MODES 

5

 FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

6

 LONG OPERATION 

7

 POWERFUL OPERATION 

7

 I-SAVE OPERATION  

7

 ECONO COOL OPERATION  

8

 TIMER OPERATION (ON/OFF TIMER) 

8

 WEEKLY TIMER OPERATION 

9

 CLEANING 

10

 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

11

 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

12

 INSTALLATION PLACE AND ELECTRICAL WORK 

12

 SPECIFICATIONS 

12

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

•  Be sure to receive a guarantee card from your dealer and check that the 

purchased date and shop name, etc. are entered correctly.

Marks and their meanings

 WARNING :

Incorrect  handling  could  cause  serious  hazard,  such  as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 

on the conditions.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

  

 :  Never insert your fi nger or stick, etc.

 : 

Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.

 : 

Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

 :  Risk of fi re.

 WARNING

Do not connect the power cord to an intermediate point, use 

an extension cord, or connect multiple devices to a single 

AC outlet.

•  This may cause overheating, fi re, or electric shock.

Make sure the power plug is free of dirt and insert it securely 

into the outlet.

•  A dirty plug may cause fi re or electric shock.

Do not bundle, pull, damage, or modify the power cord, and do 

not apply heat or place heavy objects on it.

•  This may cause fi re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the 

power plug during operation.

•  This may create sparks, which can cause fi re.

•  After the indoor unit is switched OFF with the remote controller, 

make sure to turn the breaker OFF or disconnect the power plug. 

Do not expose your body directly to cool air for a prolonged 

length of time.

•  This could be detrimental to your health.

The unit should not be installed, relocated, disassembled, 

altered, or repaired by the user.

•  An improperly handled air conditioner may cause fi re, electric 

shock, injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced by the 

manufacturer or its service agent in order to avoid a hazard.

When installing, relocating, or servicing the unit, make sure 

that no substance other than the specifi ed refrigerant (R32) 

enters the refrigerant circuit.

•  Any presence of foreign substance such as air can cause abnor-

mal pressure rise and may result in explosion or injury.

•  The use of any refrigerant other than that specifi ed for the system 

will cause mechanical failure, system malfunction, or unit break-

down. In the worst case, this could lead to a serious impediment 

to securing product safety.

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appli-

ance by a person responsible for their safety.
Children should be supervised to ensure that they do not play 

with the appliance.

  

Do not insert your fi nger, a stick, or other objects into the air 

inlet or outlet.

•  This may cause injury, since the fan inside rotates at high speeds 

during operation.

  

In case of an abnormal condition (such as a burning smell), 

stop the air conditioner and disconnect the power plug or turn 

the breaker OFF.

•  A continued operation in the abnormal state may cause a malfunc-

tion, fi re, or electric shock. In this case, consult your dealer.

WARNING

(Risk of fi re)

This unit uses a fl ammable refrigerant.

If refrigerant leaks and comes in contact with fi re or heating part, it will create harmful gas and there is risk of fi re.

Read the OPERATING INSTRUCTIONS carefully before operation.

Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.

Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like.

Meanings of symbols displayed on indoor unit and/or outdoor unit

JG79Y212H01_en.indd   1

2016/09/30   15:47:37

Содержание Mr.Slim MSY-GN18VF

Страница 1: ...RS INDOOR UNIT MSY GN18VF MSY GN24VF MSY GN30VF English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use JG79Y212H01_Cover indd 1 2016 09 30 15 46 56 ...

Страница 2: ...with the remote controller make sure to turn the breaker OFF or disconnect the power plug Do not expose your body directly to cool air for a prolonged length of time This could be detrimental to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult yo...

Страница 3: ...or unit wetting and damaging the furniture In case of an abnormal condition Immediately stop operating the air conditioner and consult your dealer Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with your skin or clothes wash them thoroughly wi...

Страница 4: ...he remote controller holder in a place where the signal can be received by the indoor unit When the remote controller is not used place it in this holder Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controlle...

Страница 5: ...shelf lives last shorter Press RESET gently using a thin instrument If the RESET button is not pressed the remote controller may not operate correctly Before operation Insert the power supply plug into the power outlet and or turn the breaker on Installing the remote controller batteries PREPARATION BEFORE OPERATION 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3...

Страница 6: ... start the operation 2 Press to select operation mode Each press changes mode in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function autom...

Страница 7: ...rizontal airflow direction Each press changes airflow direction in the following order GN30 Press to select horizontal airflow direction Each press changes airflow direction in the following order AUTO Silent Low Med High Super High AUTO 1 2 3 4 5 SWING SWING SWING Airflow direction AUTO The vane is set to the most efficient airflow direction horizontal position Manual For efficient air conditioning s...

Страница 8: ... warmer in COOL mode This setting is suit able for unoccupied room and while you are sleeping 2 Saving frequently used settings Save your preferred setting for COOL ECONO COOL This enables you to select your preferred setting with a single push of the button LONG OPERATION Press to start LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to l...

Страница 9: ...e to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time and day are set correctly Page 4 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 ...

Страница 10: ...s and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer set...

Страница 11: ... direct sunlight heat or fire to dry Do not use water hotter than 50 C Do not use a scrubbing brush a hard sponge or the like Do not soak or rinse the horizontal vane Do not apply excessive force on the fan as it may cause cracks or breakage GN30 Front panel GN18 24 Hinge GN30 only Hole Air filter Nano platinum filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water After washi...

Страница 12: ... Is the fan setting appropriate Please change fan speed to High or Super High Page 6 Are the filters clean Page 10 Is the fan or heat exchanger of the indoor unit clean Page 10 Are there any obstacles blocking the air inlet or outlet of the indoor or outdoor unit Is a window or door open When a ventilation fan or a gas cooker is used in a room the cooling load increases resulting in an insufficient ...

Страница 13: ...FAN mode for 3 to 4 hours Page 5 This dries the inside of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 10 2 Check that the air inlet and outlet of the i...

Страница 14: ...ผิดปกติ อาจเป นสาเหตุให เครื องทํางานผิดพลาด ไฟไหม หรือไฟดูด ฯลฯ ในกรณ น โปรดปรึกษาตัวแทนจําหน ายของท าน เน องจากมีการใช อุปกรณ ชิ นส วนทางเครื องกลและชิ นส วนที อาจก อให เกิดไฟดูดในผลิตภัณฑ น กรุณาตรวจสอบให แน ใจก อนว าได อ าน ข อควรระวังเพื อความปลอดภัย ก อนใช งาน เน องจากเครื องหมายคําเตือนที แสดงเหล าน มีความสําคัญสําหรับความปลอดภัย จึงควร แน ใจว าได ตรวจสอบเครื องหมายเหล าน แล ว หลังจากอ านคู...

Страница 15: ...ารตรวจสอบและบํารุงรักษา ซึ งต องอาศัยความชํานาญเฉพาะทาง ห ามใช สวิตช ขณะมือเป ยก อาจทําให ไฟดูดได ห ามทําความสะอาดเครื องปรับอากาศด วยนํ า หรือวางภาชนะที บรรจุนํ า อยู เช น แจกันดอกไม ฯลฯ ลงบนตัวเครื อง อาจทําให เกิดไฟไหม หรือไฟดูดได ห ามเหยียบ หรือวางวัตถุใดๆ ลงบนเครื องภายนอกบ าน เพราะอาจทําให เกิดอาการบาดเจ บได หากท านหรือวัตถุดังกล าวตกลงมา คําเตือน กรุณาติดต อตัวแทนจําหน ายของท านเพื อติดตั ง...

Страница 16: ...ปดาห ติดตั งที วางรีโมทคอนโทรล ในตําแหน งที เครื องภายใน บ านสามารถรับสัญญาณได เมื อไม ใช งานรีโมทคอนโทรล โปรดเก บไว ที แท นเสียบนี ใช รีโมทคอนโทรลที จัดเตรียมมากับเครื องเท านั น ห ามใช รีโมทคอนโทรลอันอื น หากมีการติดตั งเครื องภายในบ านตั งแต 2 เครื อง ขึ นไปใกล ๆ กัน เครื องภายในบ านที ไม ได ใช งาน อาจตอบรับการสั งงานจากรีโมทคอนโทรลได ปุ ม i save หน า 7 ปุ มตั งเวลารายสัปดาห หน า 9 ช องลมออก ช ...

Страница 17: ...ม แบตเตอรี อาจหมดเร วกว ากําหนด กดปุ ม RESET เบาๆ โดยใช เครื องมือชั นเล กๆ หากไม ได กดปุ ม RESET รีโมทคอนโทรลอาจทํางานไม ถูกต อง ก อนใช งาน เสียบปลั กไฟเข ากับเต ารับ และ หรือสับเบรกเกอร ขึ น การใส แบตเตอรี ในรีโมทคอนโทรล 1 ถอดฝาด านหน าออก 2 ใส แบตเตอรี อัลคาไลน ขนาด AAA ด านขั วลบ ก อน 3 ใส ฝาด านหน ากลับเข าไป 4 กดปุ ม RESET การตั งเวลาป จจุบัน 1 กดปุ ม CLOCK 4 กดปุ ม CLOCK อีกครั ง 2 กดปุ ม T...

Страница 18: ...ที ตั งไว ไม เกิน 2 C โหมด COOL เพลิดเพลินกับอากาศเย นในระดับอุณหภูมิที ท านต องการ โหมด DRY เป นการลดความชื นในห อง อุณหภูมิห องจะลดลงเล กน อย ไม สามารถตั งอุณหภูมิได ในระหว างการใช โหมด DRY โหมด FAN เป นการหมุนเวียนอากาศภายในห องของท าน หมายเหตุ หลังจากการทํางานในโหมด COOL DRY ขอแนะนําให ใช งานในโหมด FAN เพื อ ทําให ภายในของเครื องภายในบ านแห ง I FEEL COOL DRY FAN ระบบการทํางานฉุกเฉิน เมื อไม สา...

Страница 19: ...กทิศทางลมในแนวซ าย ขวา เมื อกดปุ มแต ละครั ง ทิศทางลมจะเปลี ยนไปตามลําดับดังนี GN30 กดปุ ม เพื อเลือกทิศทางลมในแนวซ าย ขวา เมื อกดปุ มแต ละครั ง ทิศทางลมจะเปลี ยนไปตามลําดับดังนี ทิศทางลม อัตโนมัติ บานเกล ดจะถูกตั งไว ที ทิศทางลมที มีประสิทธิภาพสูงสุด ตําแหน งแนวราบ ปรับเอง เพื อประสิทธิภาพในการปรับอากาศ ให เลือกตําแหน งด านบน ในโหมด COOL DRY และเลือกตําแหน งด านล างในโหมด FAN หากมีการเลือกตําแหน ...

Страница 20: ...การ ที กําหนดไว ได ด วยการกดปุ ม เพียงครั งเดียว กดปุ มอีกครั ง และท านสามารถย อนกลับไปยังการตั งค าก อนหน า ได ทันที การทํางานแบบ i save ไม สามารถตั งค าในการตั งค ารายสัปดาห ได ตัวอย างการใช งาน 1 โหมดประหยัดพลังงาน ตั งอุณหภูมิให อุ นขึ น 2 C ถึง 3 C ในโหมด COOL การตั งค าน เหมาะสําหรับห องว าง และ ในขณะนอนหลับ 2 การบันทึกการตั งค าที ใช งานบ อย บันทึกการตั งค าที ท านต องการสําหรับ COOL ECONO ...

Страница 21: ...จึงสามารถช วยประหยัดพลังงานได 1 กดปุ ม หรือ ในขณะที เครื องกําลังทํางานเพื อตั งเวลา การตั งเวลา ON เครื องจะเป ดเมื อถึงเวลาที กําหนด การตั งเวลา OFF เครื องจะป ดเมื อถึงเวลาที กําหนด หรือ กะพริบ ดูให แน ใจว าได ตั งเวลาและวันที ป จจุบันไว ถูกต องแล ว หน า 4 2 กดปุ ม เพิ ม และ ลด เพื อตั งเวลาเป ด ป ด เมื อกดปุ มแต ละครั ง เวลาที ตั งไว จะเพิ มขึ นหรือลดลงครั งละ 10 นาที ตั งเวลาในขณะที หรือ กะพร...

Страница 22: ... งเวลารายสัปดาห การตรวจสอบการตั งเวลารายสัปดาห 1 กด เพื อเข าสู โหมดการตั งเวลารายสัปดาห จะกะพริบ 2 กด หรือ เพื อดูการตั งค าเฉพาะวันหรือหมายเลขครั ง กด เพื อออกจากการตั งเวลารายสัปดาห หมายเหตุ เมื อเลือกทุกวันในสัปดาห เพื อดูการตั งค าโดยที แต ละวันมีการตั งค าแตกต างกัน จะปรากฏขึ น ตัวอักษรจะหยุด กะพริบและเวลาป จจุบันจะ แสดงขึ นมา กะพริบ หมายเหตุ การตั งเวลาเป ด ป ด ON OFF อย างง ายสามารถใช งานไ...

Страница 23: ...กระแสไฟฟ า แผ นกรองที สกปรกจะทําให เกิดหยดนํ าในเครื องปรับอากาศซึ งทําให เชื อ ต างๆ เช น เชื อรา เจริญเติบโตได ฉะนั นจึงควรทําความสะอาดแผ นกรอง อากาศทุก 2 สัปดาห แผ นกรองอากาศ แผ นกรองนาโนแพลตินัม ทําความสะอาดทุก 2 สัปดาห กําจัดสิ งสกปรกด วยเครื องดูดฝุ น หรือล างออกด วยนํ า หลังจากล างด วยนํ าเสร จแล ว ผึ งให แห งในที ร ม แผ นกรองนาโนแพลตินัม คืออะไร นาโนแพลตินัมคืออนุภาคของเซรามิคที มีอนุภาคขอ...

Страница 24: ...หน า 5 ความเร วใบพัดตั งไว เหมาะสมหรือไม โปรดเปลี ยน ความเร วใบพัดเป นสูงหรือสูงสุด หน า 6 แผ นกรองอากาศสะอาดหรือไม หน า 10 ใบพัดหรือตัวเปลี ยนความร อนของเครื องภายใน บ านสกปรกหรือไม หน า 10 มีสิ งกีดขวางที ช องลมเข าหรือช องลมออกของ เครื องภายในหรือภายนอกบ านหรือไม หน าต างหรือประตูถูกเป ดทิ งไว หรือไม หากมีการใช พัดลมระบายอากาศ หรือเตาแก สทํา อาหารภายในห อง ระบบทําความเย นจะต องทํางานหนักขึ น จึ...

Страница 25: ...าน 3 สับเบรกเกอร ลง และ หรือถอดปลั กไฟออก 4 ถอดแบตเตอรี ทั งหมดออกจากรีโมทคอนโทรล เมื อเริ มใช เครื องปรับอากาศอีกครั ง 1 ทําความสะอาดแผ นกรองอากาศ หน า 10 2 ตรวจสอบว าไม มีสิ งกีดขวางที ช องลมเข า และช องลมออกของเครื อง ภายในและภายนอกบ าน 3 ตรวจสอบว าต อสายดินถูกต องแล ว 4 ดู การเตรียมตัวก อนใช งาน และปฏิบัติตามคําแนะนํา หน า 4 เมื อไม ได ใช เครื องปรับอากาศเป นเวลานาน ข อมูลจําเพาะ รุ น MSY GN18...

Страница 26: ...JG79Y212H01_th indd 13 29 09 2016 16 43 56 ...

Страница 27: ...JG79Y212H01_th indd 14 29 09 2016 16 43 56 ...

Страница 28: ...HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79Y212H01 JG79Y212H01_Cover indd 2 2016 09 30 15 46 57 ...

Отзывы: