background image

En-6

E

CONO COOL OPERATION

Press 

 during COOL mode 

 page 4 

 to start 

ECONO COOL operation.

The unit performs swing operation vertically in various cycle according 

to the temperature of the unit. Set temperature is set 2°C higher auto-

matically.

Press 

 again to cancel ECONO COOL operation. 

•  ECONO COOL operation also is cancelled when VANE or LONG but-

ton is pressed.

What is “ECONO COOL”?

Swing air fl ow (change of air fl ow) makes you feel cooler than constant air fl ow. 

So, even though the set temperature is automatically set 2°C higher, it is pos-

sible to perform cooling operation with keeping comfort. As a result, energy can 

be saved.

L

ONG OPERATION

Press 

 to start LONG operation.

• Fan speed increases and the horizontal vane moves to the position 

for LONG mode.

• Air reaches to longer distance.

Press 

 again to cancel LONG operation.

•  LONG operation also is cancelled when the VANE or ECONO COOL 

button is pressed.

T

IMER OPERATION (ON/OFF TIMER)

1

Press 

 or 

 during operation to set the timer. 

 (ON timer) :   The unit will turn ON at the set 

time.

 (OFF timer) : The unit will turn OFF at the set 

time.

 or 

 blinks.

*  Make sure that the current time is set correctly. 

 Page 3 

2

Press 

 (Increase) and 

 (Decrease) to set the 

time of timer. 

Each press increases or decreases the set time by 10 minutes.

Press  

  or 

 again to cancel timer.

Note:

•  ON and OFF timers can be set together.   mark indicates the order of timer 

operations.

•  If power failure occurs while ON/OFF timer is set, see 

 page 4 

 “Auto restart 

function”

JG79Y031H02_en.indd   6

11/18/2015   11:35:16 AM

Содержание Mr.Slim MS-GK36VA

Страница 1: ...ING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MS GK36VA JG79Y031H02_cover indd 1 11 4 2015 1 29 46 PM ...

Страница 2: ...al to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make s...

Страница 3: ...ery fluid comes in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightnin...

Страница 4: ...splay section OFF ON stop operate button Operation select button Page 4 ECONO COOL button Page 6 FAN speed control button Page 5 VANE control button Page 5 Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote control...

Страница 5: ... C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode in the following order ...

Страница 6: ...ss changes airflow direction in the following order Vertical airflow direction AUTO The vane is set to the most efficient airflow direction Horizontal position Manual For efficient air conditioning select upper position for COOL DRY During COOL DRY when the vane is set to position 4 or 5 the vane auto matically moves to the upward position after 0 5 to 1 hour to prevent any condensation from dripping...

Страница 7: ...art LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer distance Press again to cancel LONG operation LONG operation also is cancelled when the VANE or ECONO COOL button is pressed TIMER OPERATION ON OFF TIMER 1 Press or during operation to set the timer ON timer The unit will turn ON at the set time OFF timer The unit will turn OFF ...

Страница 8: ...in air filter Catechin is a bioflavonoid that is found in green tea that has both antivi ral and antioxidant qualities In addition to these benefits Catechin also offers excellent deodorizing characteristics Catechin air filter uses this compound to not only improve air quality but also prevent the spread of bacteria and viruses in the room Front panel 1 Lift the front panel until a click is heard 2 H...

Страница 9: ... on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperature setting appropriate Page 4 Is the fan setting...

Страница 10: ...tilated dry place 500 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV recep...

Страница 11: ...ถูกวิธี อาจเป นสาเหตุให เกิดอันตรายอย าง รุนแรง ขึ นอยู กับสภาพการใช งานนั นๆ ไม ควรให บุคคล รวมทั งเด กเล ก ที มีสภาพร างกายไม แข งแรง สภาพ การรับรู หรือจิตใจไม ปกติ หรือขาดประสบการณ และความรู ความเข าใจ นําอุปกรณ น ไปใช งาน เว นแต จะอยู ในการควบคุมดูแล หรือได รับคําแนะ นําในการใช งานจากผู ที รับผิดชอบต อความปลอดภัยของบุคคลนั นๆ ได เด กเล กควรได รับการดูแลเพื อป องกันไม ให นําอุปกรณ นี ไปเล น ห า...

Страница 12: ...หมดด วยนํ าสะอาด หากของเหลวในแบตเตอรี สัมผัสกับดวงตา ควรล างออกให หมดด วย นํ าสะอาด และพบแพทย โดยทันที ควรตรวจให แน ใจว าพื นที นั นจะมีการระบายอากาศที ดีขณะที เครื อง ปรับอากาศทํางานพร อมกับเครื องใช ที มีการเผาไหม การระบายอากาศที ไม ดีเพียงพอ อาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะ เกิดฟ าผ า เครื องอาจชํารุด หากโดนฟ าผ า หลังจากใช เครื องป...

Страница 13: ...โมทคอนโทรล เครื องภายนอกบ าน ลักษณะของเครื องภายนอกบ านอาจแตกต างกันออกไป ช องลมเข า ด านหลังและด านข าง ท อนํ ายาทําความเย น ท อนํ าทิ ง ช องลมออก ช องระบายนํ าทิ ง ส วนส งสัญญาณ ระยะที สามารถส งสัญญาณได ประมาณ 6 เมตร เสียงบิ บจะดังขึ นจากตัวเครื อง ภายในบ าน เมื อเครื องได รับ สัญญาณ ปุ มปรับอุณหภูมิ หน า 4 ปุ มควบคุมความเร ว ใบพัด หน า 5 ปุ มควบคุมบานเกล ด ปรับทิศทางลม หน า 5 ปุ ม RESET หน า 3 ...

Страница 14: ...รอจนกระทั งอุณหภูมิห องลดลงถึง ระดับที ต างจากอุณหภูมิที ตั งไว ไม เกิน 2 C โหมด COOL เพลิดเพลินกับอากาศเย นในระดับอุณหภูมิที ท านต องการ โหมด DRY เป นการลดความชื นในห อง อุณหภูมิห องจะลดลงเล กน อย ไม สามารถตั งอุณหภูมิได ในระหว างการใช โหมด DRY โหมด FAN เป นการหมุนเวียนอากาศภายในห องของท าน ระบบการทํางานฉุกเฉิน เมื อไม สามารถใช งานรีโมทคอนโทรลได ท านสามารถใช ระบบการทํางานฉุกเฉินได โดยการกดสวิตช ก...

Страница 15: ...ื อเลือกทิศทางลมในแนวซ าย ขวา เมื อกดปุ มแต ละครั ง ทิศทางลมจะเปลี ยนไปตามลําดับดังนี ทิศทางลมในแนวดิ ง อัตโนมัติ บานเกล ดจะถูกตั งไว ที ทิศทางลมที มีประสิทธิภาพสูงสุด ตําแหน งแนวราบ ปรับเอง เพื อประสิทธิภาพในการปรับอากาศ ให เลือกตําแหน งด านบนในโหมด COOL DRY ใน ระหว างโหมด COOL DRY เมื อบานเกล ดถูกตั งค าที ตําแหน ง 4 หรือ 5 บานเกล ดจะ ปรับเลื อนไปยังตําแหน งขึ นด านบนโดยอัตโนมัติ หลังจากเวลาผ าน...

Страница 16: ...เพื อเริ มทํางานในระบบทําความเย นแบบ LONG ความเร วพัดลมเพิ มขึ นและบานเกล ดปรับทิศทางลมขึ น ลงจะปรับไปยังตําแหน ง ของระบบทําความเย นแบบ LONG อากาศครอบคลุมถึงพื นที ระยะไกล กดปุ ม อีกครั งเพื อยกเลิกระบบทําความเย นแบบ LONG ระบบทําความเย นแบบ LONG จะถูกยกเลิกด วย เมื อกดปุ มควบคุมบานเกล ดปรับ ทิศทางลม VANE หรือปุ มระบบความเย นแบบ ECONO COOL 1 กดปุ ม หรือ ในขณะที เครื องกําลังทํางานเพื อตั งเวลา การต...

Страница 17: ...อนใส กลับเข าไป แผ นกรองอากาศคาเตคิน คืออะไร คาเตคิน คือสารไบโอฟลาโวนอยด ที พบในชาเขียว ซึ งมีคุณสมบัติทั งต านเชื อไวรัส และมีสารต านอนุมูลอิสระ นอกจากน คาเตคินยังมีคุณลักษณะการขจัดกลิ นได อย างยอดเยี ยมอีกด วย แผ นกรองอากาศคาเตคิน ไม เพียงแต ใช สารประกอบน ในการปรับคุณภาพอากาศเท านั น ยังช วยป องกันการแพร กระจายของเชื อแบคทีเรีย และเชื อไวรัสในห องได อีกด วย สิ งสําคัญ ทําความสะอาดแผ นกรองเป นประ...

Страница 18: ... ทําความเย น และ DRY ลดความชื น ท อและจุดเชื อมท อต างๆ จะเย นตัวทําให ไอน ําเกิดการกลั นตัวได รีโมทคอนโทรล ไม มีผลแสดงการทํางานที รีโมท คอนโทรลหรือไม ชัด เครื องภายใน บ านไม ตอบสนองต อสัญญาณของ รีโมทคอนโทรล แบตเตอรี หมดหรือไม หน า 3 ใส แบตเตอรี ถูกขั วหรือไม หน า 3 มีการกดปุ มรีโมทคอนโทรลของเครื องใช ไฟฟ า ชนิดอื นหรือไม อาการ รายละเอียดและจุดตรวจสอบ อากาศไม เย น เครื องปรับอากาศทําความเย น ไม เพ...

Страница 19: ...บายอากาศได ดี อย างน อย 500 มม โทรทัศน โทรศัพท ไร สายหรือ โทรศัพท เคลื อนที อย างน อย 3 เมตร อย างน อย 1 เมตร ให ทําการติดตั งเครื องภายนอกห างจากเสาอากาศของวิทยุและโทรทัศน ไม ตํ ากว า 3 เมตร ในบริเวณที มีสัญญาณอ อนมาก ในระยะข างต นอาจ เกิดสัญญาณการทํางานของเครื องปรับอากาศแทรกในวิทยุหรือโทรทัศน ได ในกรณีเช นนี ให ทําการเพิ มระยะห างจนกว าจะปราศจากสัญญาณ แทรกรบกวน 1 ตั งอุณหภูมิไว ที ระดับสูงสุดใน...

Страница 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79Y031H02 JG79Y031H02_cover indd 2 11 4 2015 1 29 47 PM ...

Отзывы: