 I FEEL mode

The unit selects the operation mode according to the room temperature 

when I FEEL is selected. When the room temperature is higher than 25°C, 

COOL is selected (set temperature: 24°C). When the room temperature 

is lower than 25°C, DRY is selected. However, when operation is stopped 

and then started within 2 hours, the mode which has been selected previ-

ously is operated.

Note: 

During COOL operation, the set temperature may not be changed when 

the room temperature is more than 2°C higher than the set temperature. 

In this case, please wait until the room temperature drops to within 2°C of 

the set temperature.

 COOL mode

Enjoy cool air at your desired temperature. 

  DRY mode

Dehumidify your room. The room may be cooled slightly. 

Temperature cannot be set during DRY mode.

 FAN mode

Circulate the air in your room.

Operation indicator lamp

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Room temperature

The unit is operating to reach the set 

temperature

About 2°C or more  

away from set tem-

perature

The room temperature is approach-

ing the set temperature

About 1 to 2°C from 

set temperature

  Lighted 

 

Not lighted

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation 

switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in 

the following order:

1

Press 

 to start the operation.

2

Press 

 to select operation mode. Each press 

changes mode in the following order:

3

Press   or   to set the temperature.

Each press raises or lowers the temperature by 1°C.

 

Press 

 to stop the operation.

•  The same setting is selected the next time by simply pressing

 

.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto 

restart function” automatically starts operation in the same mode as the one set 

with the remote controller just before the shutoff of the main power. When timer is 

set, timer setting is cancelled and the unit starts operation when power is resumed.

If you do not want to use this function, please consult the service repre-

sentative because the setting of the unit needs to be changed.

S

ELECTING OPERATION MODES

Set temperature : 24°C

Fan speed : Medium

Horizontal vane : Auto

(I FEEL)

(COOL)

(DRY)

(FAN)

Emergency COOL

Stop

Note:

The  fi rst  30  minutes  of  operation  is  test  run.  Temperature 

control does not work, and fan speed is set to High.

JG79Y031H02_en.indd   4

11/18/2015   11:35:14 AM

Содержание Mr.Slim MS-GK36VA

Страница 1: ...ING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MS GK36VA JG79Y031H02_cover indd 1 11 4 2015 1 29 46 PM ...

Страница 2: ...al to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make s...

Страница 3: ...ery fluid comes in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightnin...

Страница 4: ...splay section OFF ON stop operate button Operation select button Page 4 ECONO COOL button Page 6 FAN speed control button Page 5 VANE control button Page 5 Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote control...

Страница 5: ... C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode in the following order ...

Страница 6: ...ss changes airflow direction in the following order Vertical airflow direction AUTO The vane is set to the most efficient airflow direction Horizontal position Manual For efficient air conditioning select upper position for COOL DRY During COOL DRY when the vane is set to position 4 or 5 the vane auto matically moves to the upward position after 0 5 to 1 hour to prevent any condensation from dripping...

Страница 7: ...art LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer distance Press again to cancel LONG operation LONG operation also is cancelled when the VANE or ECONO COOL button is pressed TIMER OPERATION ON OFF TIMER 1 Press or during operation to set the timer ON timer The unit will turn ON at the set time OFF timer The unit will turn OFF ...

Страница 8: ...in air filter Catechin is a bioflavonoid that is found in green tea that has both antivi ral and antioxidant qualities In addition to these benefits Catechin also offers excellent deodorizing characteristics Catechin air filter uses this compound to not only improve air quality but also prevent the spread of bacteria and viruses in the room Front panel 1 Lift the front panel until a click is heard 2 H...

Страница 9: ... on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperature setting appropriate Page 4 Is the fan setting...

Страница 10: ...tilated dry place 500 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV recep...

Страница 11: ...ถูกวิธี อาจเป นสาเหตุให เกิดอันตรายอย าง รุนแรง ขึ นอยู กับสภาพการใช งานนั นๆ ไม ควรให บุคคล รวมทั งเด กเล ก ที มีสภาพร างกายไม แข งแรง สภาพ การรับรู หรือจิตใจไม ปกติ หรือขาดประสบการณ และความรู ความเข าใจ นําอุปกรณ น ไปใช งาน เว นแต จะอยู ในการควบคุมดูแล หรือได รับคําแนะ นําในการใช งานจากผู ที รับผิดชอบต อความปลอดภัยของบุคคลนั นๆ ได เด กเล กควรได รับการดูแลเพื อป องกันไม ให นําอุปกรณ นี ไปเล น ห า...

Страница 12: ...หมดด วยนํ าสะอาด หากของเหลวในแบตเตอรี สัมผัสกับดวงตา ควรล างออกให หมดด วย นํ าสะอาด และพบแพทย โดยทันที ควรตรวจให แน ใจว าพื นที นั นจะมีการระบายอากาศที ดีขณะที เครื อง ปรับอากาศทํางานพร อมกับเครื องใช ที มีการเผาไหม การระบายอากาศที ไม ดีเพียงพอ อาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะ เกิดฟ าผ า เครื องอาจชํารุด หากโดนฟ าผ า หลังจากใช เครื องป...

Страница 13: ...โมทคอนโทรล เครื องภายนอกบ าน ลักษณะของเครื องภายนอกบ านอาจแตกต างกันออกไป ช องลมเข า ด านหลังและด านข าง ท อนํ ายาทําความเย น ท อนํ าทิ ง ช องลมออก ช องระบายนํ าทิ ง ส วนส งสัญญาณ ระยะที สามารถส งสัญญาณได ประมาณ 6 เมตร เสียงบิ บจะดังขึ นจากตัวเครื อง ภายในบ าน เมื อเครื องได รับ สัญญาณ ปุ มปรับอุณหภูมิ หน า 4 ปุ มควบคุมความเร ว ใบพัด หน า 5 ปุ มควบคุมบานเกล ด ปรับทิศทางลม หน า 5 ปุ ม RESET หน า 3 ...

Страница 14: ...รอจนกระทั งอุณหภูมิห องลดลงถึง ระดับที ต างจากอุณหภูมิที ตั งไว ไม เกิน 2 C โหมด COOL เพลิดเพลินกับอากาศเย นในระดับอุณหภูมิที ท านต องการ โหมด DRY เป นการลดความชื นในห อง อุณหภูมิห องจะลดลงเล กน อย ไม สามารถตั งอุณหภูมิได ในระหว างการใช โหมด DRY โหมด FAN เป นการหมุนเวียนอากาศภายในห องของท าน ระบบการทํางานฉุกเฉิน เมื อไม สามารถใช งานรีโมทคอนโทรลได ท านสามารถใช ระบบการทํางานฉุกเฉินได โดยการกดสวิตช ก...

Страница 15: ...ื อเลือกทิศทางลมในแนวซ าย ขวา เมื อกดปุ มแต ละครั ง ทิศทางลมจะเปลี ยนไปตามลําดับดังนี ทิศทางลมในแนวดิ ง อัตโนมัติ บานเกล ดจะถูกตั งไว ที ทิศทางลมที มีประสิทธิภาพสูงสุด ตําแหน งแนวราบ ปรับเอง เพื อประสิทธิภาพในการปรับอากาศ ให เลือกตําแหน งด านบนในโหมด COOL DRY ใน ระหว างโหมด COOL DRY เมื อบานเกล ดถูกตั งค าที ตําแหน ง 4 หรือ 5 บานเกล ดจะ ปรับเลื อนไปยังตําแหน งขึ นด านบนโดยอัตโนมัติ หลังจากเวลาผ าน...

Страница 16: ...เพื อเริ มทํางานในระบบทําความเย นแบบ LONG ความเร วพัดลมเพิ มขึ นและบานเกล ดปรับทิศทางลมขึ น ลงจะปรับไปยังตําแหน ง ของระบบทําความเย นแบบ LONG อากาศครอบคลุมถึงพื นที ระยะไกล กดปุ ม อีกครั งเพื อยกเลิกระบบทําความเย นแบบ LONG ระบบทําความเย นแบบ LONG จะถูกยกเลิกด วย เมื อกดปุ มควบคุมบานเกล ดปรับ ทิศทางลม VANE หรือปุ มระบบความเย นแบบ ECONO COOL 1 กดปุ ม หรือ ในขณะที เครื องกําลังทํางานเพื อตั งเวลา การต...

Страница 17: ...อนใส กลับเข าไป แผ นกรองอากาศคาเตคิน คืออะไร คาเตคิน คือสารไบโอฟลาโวนอยด ที พบในชาเขียว ซึ งมีคุณสมบัติทั งต านเชื อไวรัส และมีสารต านอนุมูลอิสระ นอกจากน คาเตคินยังมีคุณลักษณะการขจัดกลิ นได อย างยอดเยี ยมอีกด วย แผ นกรองอากาศคาเตคิน ไม เพียงแต ใช สารประกอบน ในการปรับคุณภาพอากาศเท านั น ยังช วยป องกันการแพร กระจายของเชื อแบคทีเรีย และเชื อไวรัสในห องได อีกด วย สิ งสําคัญ ทําความสะอาดแผ นกรองเป นประ...

Страница 18: ... ทําความเย น และ DRY ลดความชื น ท อและจุดเชื อมท อต างๆ จะเย นตัวทําให ไอน ําเกิดการกลั นตัวได รีโมทคอนโทรล ไม มีผลแสดงการทํางานที รีโมท คอนโทรลหรือไม ชัด เครื องภายใน บ านไม ตอบสนองต อสัญญาณของ รีโมทคอนโทรล แบตเตอรี หมดหรือไม หน า 3 ใส แบตเตอรี ถูกขั วหรือไม หน า 3 มีการกดปุ มรีโมทคอนโทรลของเครื องใช ไฟฟ า ชนิดอื นหรือไม อาการ รายละเอียดและจุดตรวจสอบ อากาศไม เย น เครื องปรับอากาศทําความเย น ไม เพ...

Страница 19: ...บายอากาศได ดี อย างน อย 500 มม โทรทัศน โทรศัพท ไร สายหรือ โทรศัพท เคลื อนที อย างน อย 3 เมตร อย างน อย 1 เมตร ให ทําการติดตั งเครื องภายนอกห างจากเสาอากาศของวิทยุและโทรทัศน ไม ตํ ากว า 3 เมตร ในบริเวณที มีสัญญาณอ อนมาก ในระยะข างต นอาจ เกิดสัญญาณการทํางานของเครื องปรับอากาศแทรกในวิทยุหรือโทรทัศน ได ในกรณีเช นนี ให ทําการเพิ มระยะห างจนกว าจะปราศจากสัญญาณ แทรกรบกวน 1 ตั งอุณหภูมิไว ที ระดับสูงสุดใน...

Страница 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79Y031H02 JG79Y031H02_cover indd 2 11 4 2015 1 29 47 PM ...

Отзывы: