21
E
Operating
Items to prepare
¡
Commercially available hose (I.D. 15mm)
Long enough to reach the drain
¡
Pincers
Continuous Drainage
If a drain is available, the unit can continuously drain excess water by attaching a commercially available hose
(internal diameter 15mm).
The unit can be operated for extensive periods without the need to empty the water tank.
1
Remove the
water tank.
2
Open the
drainage
outlet.
Use pincers to cut away the three securing ribs of
the continuous drainage outlet. Remove carefully
without letting any debris fall inside.
3
Press drain stopper.
4
Insert the hose into the drainage
outlet on the back.
Feed the commercially available
hose (ID 15 mm) into the
drainage outlet while keeping
the stopper pressed
5
Attach the tank and set the end
of the hose in the drain.
The unit cannot operate without returning the tank.
CAUTION
Do not drain water continuously
if there is a possibility that
temperatures around the hose could
drop below freezing point.
Water inside the hose may freeze and water may leak
from the unit and
damage surrounding objects
.
When draining water continuously or
left unattended for long periods,
inspect the unit once a fortnight.
Foreign objects, etc. could clog the hose
resulting in overheating and/or leakage
.
Drain
Stopper
Push here
Confirm that the
hose is securely
attached and does
not leak.
How to set up the drainage hose
Water cannot be drain if the
hose is immersed in water or
the hose is positioned higher
than the drainage outlet.
Hose
Note
∞
Confirm that the hose does not show signs of deterioration such as bending, cracks and clogging.
∞
Inspect the hose every 2 weeks.
Insects or dirt blocking the hose may cause leakage resulting in malfunctions.
e_mj_e20txh(20_26)_e33.qx 10/17/03 8:40 PM Page 21