background image

 

 

 

 
 

 

FDNF96 DEHUMIDIFIER 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

USER AND MAINTENANCE MANUAL 

 

 
 
 

Moisture Cure 

PO Box 5071 

Port Macquarie   New South Wales    2444 

Australia 

 
 
 
                                                                                                                                                                     

Содержание FDNF96

Страница 1: ...FDNF96 DEHUMIDIFIER USER AND MAINTENANCE MANUAL Moisture Cure PO Box 5071 Port Macquarie New South Wales 2444 Australia ...

Страница 2: ...onnected to power could cause water to come into contact with electrical parts It is therefore recommended to remove the plug from the socket before moving the dehumidifier Correct Distance this dehumidifier draws in the air from the back and lets out through the front side grill therefore the back panel which supports the air filter must be kept at a minimum distance of 15cm from the wall This de...

Страница 3: ...uted by according to safety and electro magnetic compatibility to European Norms and Regulations MACHINES NORMS 2006 42 CE 17 05 2006 SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006 95 CE 12 12 2006 ELECTROMAGNETIC COMPATIBILITY EMC 2004 108 CE 15 12 2004 It is hereby certified that this Dehumidifier conforms to the IEC Regulations CEI EN 60335 2 40 CEI EN 55014 1 55014 2 The machine is built...

Страница 4: ...ower Consumption at 35 C 95 rh 1350 w Absorbed Current at 35 C 95 rh standard ver 7 2 A Locked Rotor Current LRA 29 Air Flow 1000 cm h Noise level at 3 meters 52 dB Refrigerant R134a Standard Defrosting Control System Electronic Hot Gas Defrosting Control System optional Electronic thermostat Water Tank Capacity 15 kg Continuous Drainage Pipe Connection 25mm Temperature Range standard version 7 35...

Страница 5: ... M1 ev M2 fan Moisture Cure Pty Ltd 02 6584 2511 www moisturecurecommercial com au sales moisturecure com au LEGEND 1 COMPRESSOR 2 FAN MOTOR 3 ELECTRONIC CARD 4 HUMIDISTAT ELECTRONIC 5 MICRO SWITCH 6 ELECTRO VALVE 7 THERMOSTAT 8 HOUR COUNTER ...

Страница 6: ...nser 3 Finally the fan motor 4 expels the air back into the room through the front grill panel The condensed water is collected in the tank 5 A micro switch 6 stops the machine when the water in the tank reaches the correct level by raising the water float lever The humidistat 7 starts the functioning of the dehumidifier when the humidity is higher than the preset level An electronic circuit 8 con...

Страница 7: ...f power to the machine If the light WORKING is still off turn knob on the control panel clockwise until the light WORKING is ON The light DEFROST PAUSE will also switch on and after about 5 minutes the dehumidifier will start dehumidifying When the red light is ON ALARM the machine will not start one must check that the water tank is empty and that it is inserted correctly With machines that have ...

Страница 8: ...ined into a floor waste or similar The pump will work automatically controlled by a ball cock placed inside the pump Before moving the machine remember to purge water from water tank If the pump cannot work correctly the compressor stops and the green light turns on In this case check the pipe situation Maximum head working pressure of the pump is about 3 5 metres 7 PERIODICAL MAINTENANCE AIR FILT...

Отзывы: