(10) Removing and replacing the
fl
oat switch
①
Remove the blower fan assembly.
(See (7) Removing and replacing the
blower net and the blower motor)
②
Remove the connector P12 on the control
board.
③
Remove the
fl
oat switch set screw(1) from
the drain pan assembly to remove the
fl
oat
switch.
→
(Removing and replacing the
fl
oat
switch)
②
③
Remove the
connector P12
Control board
Float switch
Float switch
set screw(1)
Float
switch
Float
switch
set screw
(9) Removing and replacing the solenoid valve
①
Remove the board holder from the power
supply board assembly.
→
(See (6)
Removing and replacing the power supply
board)
②
Disconnect connector P6 from the power
supply board.
③
Remove the solenoid valve set screw(1) to
remove the solenoid valve.
→
(Removing
and replacing the solenoid valve)
②
③
Remove connector P6
Power supply board
Solenoid valve set screw (1)
Solenoid valve
Содержание MJ-E14EG-S1-IT
Страница 2: ...2 1 Precautions 2 Note This page is extracted from the instruction manual ...
Страница 3: ...3 3 Note This page is extracted from the instruction manual ...
Страница 4: ...4 2 Names and Functions of Parts Note This page is extracted from the instruction manual ...
Страница 8: ...8 7 Technical Points Note This page is extracted from the instruction manual ...
Страница 18: ...18 Note This page is extracted from the instruction manual 10 Troubleshooting ...
Страница 19: ...19 Note This page is extracted from the instruction manual ...
Страница 20: ...20 11 Maintenance Note This page is extracted from the instruction manual ...
Страница 33: ...33 ...