+ICF – Data Format
This Command sets data format of serial interface.
Defined parameters:
<format>
<parity>
<format>
<parity>
1: 8 Data 2 Stop
0: Odd
4: 7 Data 2 Stop
3: Space
2: 8 Data 1 Parity 1 Stop
1: Even
5: 7 Data 1 Parity 1 Stop 4: None
3: 8 Data 1 Stop
2: Mark
6: 7 Data 1 Stop
If <format> is 1, 3, 4 or 6, <parity> will be ignored
+IFC – Flow Control
This Command determines flow control on serial interface.
Defined parameters:
< DCE_by_DTE >
< DTE_by_DCE >
0: none
0: none
2: RTS
2: CTS
Appendix
AT Commands MIM-G01
Mitsubishi Industrial Modem
8 - 3
Command
Possible answers
AT+ICF?
+ICF: <format>,<parity>
OK
Note: current values
AT+ICF=<format>,<parity>
OK
Tab. 8-6:
+ICF – Data Format
Command
Possible answers
AT+IFC?
+IFF: <DCE_by_DTE>,<DTE_by_DCE>
OK
Note: current values
AT+IFC=<DCE_by_DTE>,<DTE_by_DCE>
OK
Tab. 8-7:
+IFC – Flow Control