7 CiA 402 DRIVE PROFILE
7.1 PDS state transitions
25
7
The commands issued to the servo amplifier are shown in the table below. Turn on the bits relative to the command.
0: Off 1: On
: Either on/off can be used
*1 In order to avoid missing the command at the time of a communication error, maintain the state of Bit 7 = 1 on the Fault Reset command
for at least 10 ms when the communication cycle is 4 ms or less, or at least 20 ms when the communication cycle is 8 ms or less.
In order to transition from the "Switch on disabled" state to the "Operation enabled" state, it is necessary to give the
commands "Shutdown", "Switch On", and "Enable operation" sequentially. It is also possible to transition directly from the
current state to the target state with one command.
Command
Bit setting of Controlword command
Transition No.
Bit 7
Fault Reset
Bit 3
Enable
Operation
Bit 2
Quick Stop
Bit 1
Enable
Voltage
Bit 0
Switch On
Shutdown
0
1
1
0
(2), (6), (8)
Switch On
0
0
1
1
1
(3)
Disable Voltage
0
0
(7), (9), (10), (12)
Quick Stop
0
0
1
(7), (10), (11)
Disable Operation
0
0
1
1
1
(5)
Enable Operation
0
1
1
1
1
(4), (16)
Fault Reset
0
→
(15)
Current state
Command
State after transition
Switch on disabled
Switch on
Switched on
Switch on disabled
Enable operation
Operation enabled
Ready to switch on
Enable operation
Operation enabled