4 PDO (Process Data Object) COMMUNICATION
4.3 PDO default mapping
TxPDO default mapping
With the TxPDO default mapping, status data is transmitted to a master station (controller) using a TxPDO in the array shown
in the following table.
Map No.
Initial mapping settings
Applications expected to be used for initial
mapping
1st TxPDO map
A-axis: 1A00h
B-axis: 1A10h
C-axis: 1A20h
Modes of operation display (Obj. 6061h)
Padding (1 byte)
Statusword (Obj. 6041h)
Status DO 1 (Obj. 2D11h)
Status DO 2 (Obj. 2D12h)
Status DO 3 (Obj. 2D13h)
Position actual value (Obj. 6064h)
Velocity actual value (Obj. 606Ch)
Following error actual value (Obj. 60F4h)
Torque actual value (Obj. 6077h)
Cyclic synchronous position mode (csp)
Cyclic synchronous velocity mode (csv)
Cyclic synchronous torque mode (cst)
Homing mode (hm)
This initial mapping is for an application in which the
modes above are switched and used.
This mapping is also for an application in which the
following modes are switched and used.
• Profile position mode (pp)
• Profile velocity mode (pv)
• Profile torque mode (tq)
• Homing mode (hm)
Map size: 26 bytes
2nd TxPDO map
A-axis: 1A01h
B-axis: 1A11h
C-axis: 1A21h
Unassigned
3rd TxPDO map
A-axis: 1A02h
B-axis: 1A12h
C-axis: 1A22h
Unassigned
4th TxPDO map
A-axis: 1A03h
B-axis: 1A13h
C-axis: 1A23h
Unassigned