Platinum catalyst and activated charcoal filter
15
Maintenance
When There is an Odor Coming Out of the Air Outlet
1
Remove the inlet panel, pre-filter unit,
and HEPA filter.
P.8
2
Remove the activate charcoal filter.
P.8
3
Remove the platinum catalyst.
Hook your fingers around the handles at the bottom of the
platinum catalyst and then pull the catalyst out toward you to
remove it.
4
Soak and wash the platinum catalyst
and activated charcoal filter.
l
Platinum catalyst
Soak in cold or lukewarm water
for approximately one hour and
then wash in water.
l
Activated charcoal filter
Soak in cold or
lukewarm water for
approximately one
hour and then wash
in water.
Do not use detergent. Also, do not scrub it.
This may cause the platinum catalyst and activated charcoal
filter to become damaged.
5
Allow the platinum catalyst and
activated charcoal filter to dry.
Allow them to dry properly in a well-ventilated place in the
shade for approximately six hours (the drying time differs
depending on the season and climate).
l
Do not use them while they are still wet.
Water drops may be blown from the air outlet and an odor
may be created.
l
Soaking and washing will not completely restore the
deodorizing performance of the activated charcoal filter.
Replace this filter when the time for replacement is
reached.
6
Attach the platinum catalyst to the
main unit.
Hook the top of the platinum catalyst and then push in the
bottom.
7
Attach the activated charcoal filter to
the main unit.
P.8
8
Attach the HEPA filter, pre-filter unit,
and inlet panel to the main unit.
P.8