Installation method (continued)

Definition of symbols

M1 :

Motor for exhaust fan

M2 :

Motor for supply fan

C  :

Capacitor

GM :

Motor for Bypass movement

LS :

Microswitch

TH1:

Thermistor for outside air

TH2:

Thermistor for return air

SW1:

Switch(Main/sub change)

SW2,5: Switch(Function selection)
TM1:

Terminal block(Power supply)

TM2:

Terminal block
 (External control input)

TM3:

Terminal block(Monitor output)

TM4:

Terminal block
 (Transmission cable and monitor output)

TB5:

Terminal block
  (M-NET Transmission cable)

TAB1,TAB2:

Connector(Power supply)

TR1:

Control circuit transformer

TR2,TR3:

Bypass movement transformer

X10,X11,X12 :

Relay contact

X101,X102,X103:

Relay Supply fan speed control

Wire connection diagram ----- Models LGH-150 and 200 RX

5

* Connect the wires shown as thick lines.
* Be sure to connect the ground wire.
* A power supply isolator must be installed when wiring power supply to unit.
* Always use a single pole isolator for the main switch power connection.

X201,X202,X203 :

Relay Exhaust fan speed control

CN1:

Connector(Transformer primary)

CN2:

Connector(Transformer secondary)

CN5:

Connector(Thermistor)

CN7:

Connector(Motor for Bypass
operation)

TAB3:

Tab connector(Fan motor)

TAB5:

Tab connector(Fan motor)

CN9:

Connector(Fan motor)

CN10:

Connector(Fan motor)

CN16:

Connector(High/Low/
BY-PASS switch)

CN32:

Connector
(Remote control selection)

SA1:

Address setting rotary switch

                           (10 digit)
SA2:

Address setting rotary switch

                           ( 1 digit)
SYMBOL

 

: Terminal block

 

: Connector
: Board insertion connector

or fastening connector of
control board.

2

1

TM4

S

B

A

TB5 M-NET

* When the optional Remote Controller

PZ-60DR-E is used as the M-NET System,
connect it to 

1

2

 of TM4 terminal block,

and connect M-NET transmission wire to 

A

,

B

 

 on TB5 terminal block.

2nd remote controller
(Max. 2 remote controllers 
installable)

*

2

 PZ-41SLB-E and PZ-52SF-E

cannot be used when using
PZ-60DR-E.

M-NET
Transmission cable

Shielded wire

2nd or later main units

*

2

Optional Remote Controller
(PZ-60DR-E)

M

C

C

*1   LGH-200RX

5

 has 2 capacitors per mortor as following drawing. 

BLACK

BLACK

LS

LS

BLACK

BLACK

RED

WHITE

TR3

RED

WHITE

TR2

x201

x202

x203

x101

x102

x103

*1

*1

*1

*1

M

M

M

1

2

M

2

1

EXHAUST

SUPPLY

EXHAUST

FAN MOTOR

FAN MOTOR

FAN MOTOR

SUPPLY
FAN MOTOR

C

C

C

C

M-NET

transmission

cable

MELANS

(non-polar)

Mr.Slim

MAX 240VAC 1A

   24VDC 1A

MIN  220VAC 100mA 5VDC 100mA

Bypass or Delay2 
monitor output 

6

,

7

Malfunction monitor
output 

7

,

8

Sheilded Wire

2nd lossnay unit (Up to max 15 units)

2nd remote controller (Max. 2 remote controllers installable)

220-240V  50Hz

POWER SUPPLY

12V or 24V DC

BROWN

RED

TM4

CN16

10

8

7

6

1

2

3

CN5

1

2

9

A

B

S

X10

CN32

X11

X12

Isolator

TAB2

TAB1

CN9

CN10

TAB5

TAB3

TM3

TB5

Transmission

cable

60DR-E

PZ-

BROWN

TM2

ORANGE

ORANGE

ORANGE

ORANGE

TH2(RA)

TH1(OA)

SW1

SW5

SW2

SA1 SA2

BLACK
GREY
YELLOW

ORANGE

WHITE

BLUE

BLUE

RED

BROWN

BROWN

BLUE

CN7

CN2

CN1

TM1

Operation or Delay1

monitor output

PE

N

N

L

L

MAX 240VAC 2A MIN 220VAC 100mA

   24VDC 2A

 5VDC 100mA

(non-polar)

TR1

GM MG

x103

x102

x101

x203

x202

x201

GREEN/YELLOW

BROWN

BLACK
GREY
YELLOW

BROWN
BLACK
GREY
YELLOW

ORANGE

WHITE

BLUE

RED

ORANGE

WHITE

BLUE

RED

CN16(Uncharged a-contact)

RED

ORANGE

YELLOW

GREEN

HI

LO

BY-PASS

BROWN

1

3

External control input

Uncharged a-contact

GM MG

Содержание Lossnay LGH-150RX5-E

Страница 1: ...s a result of incomplete combustion Do not use at a place where it is exposed to high temperatures 40 C or higher naked flames or in environment with combustible fumes It could cause fire Do not use in an environment such as a chemical factory where hazardous gases such as acidic gases alkaline gases organic solvent fumes paint fumes or gases containing corrosive components are generated It could ...

Страница 2: ...200 RX5 Model A B C D Weight kg LGH 150 RX5 1004 690 690 1045 105 LGH 200 RX5 1231 917 917 1272 118 Unit mm Accessory parts Duct connecting flanges x4 Mounting screws x16 Slim Lossnay connection cable gray two wires x1 Ceiling suspension fixture 4 15 x 30 oval SA supply air RA return air EA exhaust air outlet OA outside air intake Core air filter High Efficiency filter fan maintenance space Lossna...

Страница 3: ...de air intake Supply air grille not included Except the 150 and 200 RX5 Remote controller optional parts EA exhaust air outlet OA outside air intake It can be installed by inverting the top and the bottom After installing the duct connecting flange remove the maintenance cover Turn the cover by 180 and then reinstall it Maintenance space Lossnay unit Inspection opening EA exhaust air outlet OA out...

Страница 4: ...is recommended that the indoor ductwork be covered with insulation material Do not carry out the following types of duct construction Doing so could cause a drop in the air volume and generate abnormal noises 5 When changing the direction of the out door side duct EA OA Except for LGH 150 and 200 RX5 1 Removal of flange cover Unscrewing the flange cover mounting screws 4 pcs remove the flange cove...

Страница 5: ...is product the wiring installation method will vary according to the design of the system Perform electrical installation to meet local electrical regulations Always use double insulated PVC cable for the transmission cables Wiring work must be performed by qualified professionals All supply circuits must be disconnected before obtaining access to the terminal devices M1 Motor for exhaust fan M2 M...

Страница 6: ...onnector of control board 2 1 TM4 S B A TB5 M NET When the optional Remote Controller PZ 60DR E is used as the M NET System connect it to 1 2 of TM4 terminal block and connect M NET transmission wire to A B on TB5 terminal block 2nd remote controller Max 2 remote controllers installable 2 PZ 41SLB E and PZ 52SF E cannot be used when using PZ 60DR E M NET Transmission cable Shielded wire 2nd or lat...

Страница 7: ...nnected to single input terminal is up to 4 wires for ø0 65 PVC wire or 0 3 mm2 stranded wire It is up to 2 wires for any other wires PZ 41SLB E cannot be used when MELANS centralized control of the Lossnay is used PZ 60DR E and PZ 41SLB E cannot be installed simultaneously 1 Connect the output signal cable from the external device to the input terminal block TM2 of the external controller CAUTION...

Страница 8: ...3 3 and the negative side to 1 1 1 1 1 2 Confirm that the pulse input switch SW2 2 is set to OFF Set to OFF at time of shipment When the external device has a charged operating signal of 12 VDC or 24 VDC Connect the operating signal wire from the external device via the remote output to 1 and 2 on the external control input terminal block TM2 No polarity 1 Move the pulse input switch SW2 2 to the ...

Страница 9: ...y Contactor rating DC 1 mA When connecting to the City Multi Lossnay remote controller PZ 52SF E or Mitsubishi Electric Air Conditioner Network System MELANS 10 Remote ON OFF adaptor Optional PAC SA88HA E When SW1 is ON fan speed of the Lossnay will be set to Low regardless of the remote control setting Use this in such a way that it ventilates at High fan speed normally and when the external sens...

Страница 10: ...roller When interlocking with Mitsubishi Free Plan air conditioner Incase of PZ 60DR E Limit the total length of transmission wires no longer than 500 m Limit the wiring length between Lossnay and the power supply unit Optional or the outdoor unit no longer than 200 m M NET transmission cable Lossnay M NET transmission cable Power supply unit Lossnay MELANS M NET transmission cable Air conditioner...

Страница 11: ...door OA air temperatures and automatically select the Lossnay ventilation or Bypass ventilation With this mode however priority is given to the Bypass ventilation This setting reflects to the night purge operation condition Bypass automatic ventilation priority setting 5 OFF ON 7 7 SW2 Operation When outdoor temperature OA is 28 C or higher within 24 hours then Bypass ventilation starts by the com...

Страница 12: ...pply fan is stopped during defrosting of the air conditioner when Mr Slim or City Multi indoor unit is connected to a duct When the outdoor air is lower than 15 C stop the operation of exhaust fan OA stop operation at cold region Operation Exhaust fan operation factory setting Exhaust fan stop exhaust fan operation at Low speed at outdoor air lower than 15 C OFF ON 3 3 SW5 Settings for automatic r...

Страница 13: ...the external device has come off of the external control input terminal Check in the case of multiple units whether the Main Sub selection switch on the Lossnay unit which is connected to the external control input terminal is set on the Master setting and check whether the Main Sub selection switch on other Lossnay units are set to Sub Check that the trial operation switch SW2 1 is set to off Cha...

Отзывы: