—9—
• Unplug the relay connector, and measure the
resistance at two places between each pair of the
power switch's "brown" and "blue" lead wires.
• Replace the control circuit if other than above.
• Is the sensor's lead wire connector (CN2) connected?
• Unplug the control circuit's CN2 (3-pin connector),
measure the voltage between pins 1 and 2 as well as
pins 1 and 3 of the CN2 by diode check (measure on
the lead wire side).
• Replace the control circuit if other than above.
Error mode display
Cause
Check procedure and action to take
LED1
LED2
Power
Inspection
●
●
Measured value Decision/action
1.5 to 1.8V
Normal
(No display, no operation)
LED1
LED2
Power
Inspection
●
●
(Operates, but no display)
4.Power switch
5.Control circuit
1.Display board
2.Control circuit
• Is the filter clogged with dust and the like?
→
If so,
clean the filter.
• Are the temperatures of the control circuit and
electronic parts too high?
→
If so, turn OFF the power
switch and lower the temperatures to normal
temperatures (40
˚
C or less).
• Replace the control circuit if other than above.
• When the operation time exceeds 30 seconds, the
operation stops by the activated mischievous use
prevention timer.
• Are the sensor's three windows stained?
• Is the sensor's lead wire connector connected?
• Are the sensor's board positions displaced (top/bottom
light emitting boards, light receiving board)?
• Measure the forward voltages of the LEDs on the
top/bottom light emitting boards and the photo diode
(PHD) on the light receiving board with a measuring
device that has a diode check function.
* Replace the top/bottom light emitting boards and the
light receiving board if the measured values are
other than the normal values shown in the table
above.
• Replace the control circuit if other than above.
LED1
LED2
Power
Inspection
✩
✩
1.Filter clogged with dust
2.PTC operation (control
circuit)
3.Control circuit
1.Continuous operation
2.Stained sensor's
windows
3.Disengaged sensor
4.Displaced sensor's
board positions
5.Sensor light
emitting/receiving
diode failure
6.Control circuit
(Heat sink overheat)
LED1
LED2
Power
Inspection
✩
●
(Mischievous use
prevention timer)
Item name
Measured value Decision
LED
0.9 to 1.2V
Normal
Photo diode
0.5 to 0.8V
Normal
– side
+ side
Tester
Содержание JT-SB216DS-W-AUS
Страница 7: ... 7 5 Wiring diagrams ...
Страница 24: ... 25 13 Board diagram and items to check ...
Страница 27: ... 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 19 6 19 19 19 19 19 19 19 6 19 ...
Страница 29: ... 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 19 49 49 49 48 49 49 49 45 47 46 42 15 ...
Страница 31: ... 32 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 19 68 68 68 19 19 19 19 62 42 42 18 ...
Страница 33: ... 34 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 81 19 19 19 19 ...
Страница 34: ...Printed in Japan April 2006 35 MEE ...