Dimensions

(unit: mm)

8

8

A

206

110

20

130

509

C

B

200

250

35

264

8-12

×

21

Mounting holes

Vinyl cabtyre cable
effective length: 1m

Dimensions (unit: mm)

MK-5010T-E
MK-5012T-E

1,018
1,260

A

Model

318
560

B

718
960

C

(unit: mm)

Dimensions (unit: mm)

GK-3506SA
GK-3509SA
GK-3512SA

600
900

1,200

A

Model

-

76

355.5

B

287.5

588

867.5

C

4
8
8

D

238

18.5

C

50

150

B

A

20

292

85

18

300

14.5

14.5

D-12 x 21 Slotted hole

Power switch

Air volume switch

Vinyl cabtyre cable

3 conductors x 0.75mm

2

effective length:1m

Direction of
rotation

Air flow

direction

air flow
direction

GK-35 type

MK-50 type

GK-35 type

MK-50 type

1.Operating ambient temperature and humidity must be kept. If the Product is run outside the ranges indicated in 

the guide book, burnout, distortion, poor motor rotation, and/or damages of the Product may result.

2.When the air curtain is run, the target room must be ventilated since its doorway(s) is blocked.
3.If the air curtain is installed at the place where the building may leak, such building should be made waterproof.
4.The Product must be assuredly installed in a strong and resilient area.
5.Do not block off the intake and supply openings. Otherwise, excessively heated motor may cause fire.
6.Always install the air curtain in indoor.
7.Earth Leakage Circuit Breaker should be provided for the system.
8.Add protective appliances such as motor breaker to the wiring system to prevent motor and its circuit(s) from 

burning. As a guide, choose motor breakers activating at a current 1.2 to 1.5 times the included value to prevent 
malfunctions from occurring.

Before beginning installation:

*Installation method differs with mounting location and surface, therefore, for each case make sure the correct 

installation method is utilized.

*For vertical installation, install unit in an upright position, following the wall mounting steps detailed below.
*When metal hangers are used, utilize the decorative panel to prevent insulation degradation and to stop outside 

dust and rain from entering (does not apply to recessed mounting).

Precautions

Installation Method

GK High Power type

Common

GK/MK type

*Specifications may be subject to change without notice.

Specifications (GK type)

GK-3506SA

GK-3509SA

GK-3512SA

Model

Power

Fan speed

Single-phase,

50Hz

220-240V

Input (W)

Current (A)

Air velocity

Max. (m/sec)

Air volume (m

3

/h)

Noise (dB)

Weight (kg)

Width
of unit

(cm)

60

90

120

165-175

165-180

250-265

250-270

335-355

335-360

High

Low

High

Low

High

Low

0.75-0.75

0.75-0.75

1.1-1.1

1.1-1.1

1.5-1.5

1.5-1.5

16.0-17.5

12.0-14.0

16.0-17.5

12.0-14.0

16.0-17.5

12.0-14.0

1,440-1,560

1,190-1,350

2,160-2,340

1,790-2,030

2,880-3,120

2,380-2,700

64.5-66.5

61.0-64.0

66.0-68.5

63.0-66.0

67.5-70.0

64.5-67.5

Starting Current

(A)

1.4

1.3

2.1

1.9

2.8

2.6

15.5

20

25

*Specifications may be subject to change without notice.

Specifications (MK type)

MK-5010T-E

MK-5012T-E

Model

Power

Frequency (Hz)

Three-phase,

50/60Hz

380-440/380V

Input (W)

Current (A)

Air velocity

Max. (m/sec)

Air volume (m

3

/h)

Noise (dB)

Weight (kg)

Width
of unit

(cm)

101.8

126

336-368

432

420-460

540

50

60

50

60

0.64-0.67

0.74

0.80-0.84

0.93

16

17

16

17

3,950

4,250

5,000

5,400

62

64

63.5

63.5

Starting Current

(A)

2.3

2.0

2.9

2.5

25.5

32

A

Y

H

W

Y+A

*GK-25,30 type  A = 150mm minimum
 

 

GK-35 type  A = 200mm minimum

 

 

MK-50 type  A = 250mm minimum

Metal hanger

Partition board (Provided by customer)

Universal register or return grill (Provided by customer)

Incline the unit towards the wall.
Arrange the air curtain so that it fits inside the grill.
Use a universal register and return grill with a louver installed toward the shorter dimensions.
For Y dimensions, please see the unit’s outer diagram. For W and H dimensions please contact the grill manufacture.
Bring the grill and unit into close proximity.
Make sure to install the partition boards.

Example of ceiling recessed mounting

Example of wall mounting

Example of ceiling mounting

35mm or more

Wall mounting plate
(accessory)

Metal hanger

*

Wall mounting plate
(Included item)

Angle adjustment screw

*GK-25,30 type = 100mm minimum
 

 

GK-35 type, MK-50 type = 150mm minimum

For mounting on concrete or steel frame 
or column

Secure mounting bolts so that they protrude 
approximately 15mm from the mounting surface.
Make certain to secure the wall mounting plate with 
the washers, spring washers and nuts provided.

For mounting on concrete or steel frame 
or column

Secure mounting bolts so that they protrude 
approximately 15mm from the mounting surface.
Make certain to secure the wall mounting plate with 
the washers, spring washers and nuts provided.

Example of wall mounting

Metal hanger

Decorative panel

Secure the decorative panel to the back of the 
metal hanger.
Secure the metal hanger using the mounting 
method which corresponds to the composition 
of the mounting surface material.
Secure the metal hanger mounting bolts with 
the washers, spring washers and nuts provided 
with the wall mounting plate.

Secure the metal hanger using the mounting 
method which corresponds to the composition 
of the mounting surface material.
Secure the metal hanger mounting bolts with 
the washers, spring washers and nuts provided 
with the wall mounting plate.

Example of ceiling mounting

GK/MK

High-Power type

MODEL

Service conditions: The temperature should be between -10 and +45°C, both  ambient and 
delivered. The RH should be less than 90% at room temperature. Any condition outside of 
this range could result in burnout, deformed, malrotating or damaged parts.

Note

Содержание GK-2509YS

Страница 1: ...ecting the control switch is designed to accommodate a cabie with a diameter of 1 6mm or 2 0mm only Therefore a stranded cable cannot be connected AIR CURTAIN ON OFF Switch Operation lamp FS 04SW1 E HIGH LOW Switch LOW HIGH COMMON AIR CURTAIN LOW HIGH COMMON 1 3 4 2 1 3 0 Wiring Three phase unit Connecting the FS 04SW1 E For single phase unit A Hidden Barrier Giving Tangible Benefits A I R C U R T...

Страница 2: ...internally and externally ExtraFan is a major improvement over the Line Flow Fan The fan is driven by an energy efficient motor and costs even less to operate The use of Axial Fan ExtraFan makes it easier to maintain the unit and keep the air curtain in top condition at all times Moreover the improvements that have resulted from the change to the Axial Flow Fan from the Line Flow Fan mean that fan...

Страница 3: ... comparatively low Economic benefits of installing an air curtain Savings are calculated using an appropriate heating load factor required to keep room temperature constant at 28ºC for a room measuring 66 4m2 in area Revising the Performance Records on Shut Outs Air Curtains Increased Cold Storage Efficiency and Shut Out Effect Insect Shut Out Test HEATING MODE Economic benefits of installing an a...

Страница 4: ...um angle is indicated The above figure is posted based on the values calculated by applying the average blowout velocity In order to prevent insects from breaking into the room the air flow blown out from the air curtain must reach the attainment point at a velocity at least that indicated in the table below Choose an optimum model by consulting the figure posted on the page 11 denoting the averag...

Страница 5: ...wind 4 Install the air curtain which is the same as or slightly wider than the width of the doorway 7 To run effectively the air curtain concurrently with ventilating fan s provide ventilating or air supply opening s to avoid negative pressure to occur inside the room Otherwise run the ventilating fan of a type concurrent feeding and discharging 5 Do not leave spacing between the air curtain and t...

Страница 6: ...t A clean warehouse environment is therefore preserved Bowling Alleys Lounges The air curtain can invisibly shut out areas that do not require air conditioning For example there is no need to air condition the lane side of a bowling alley so the air curtain acts as an air conditioning zoning device The elimination of unnecessary air conditioning cuts down on costs without compromising on the provi...

Страница 7: ...0 1 760 1 950 1 350 1 400 1 330 1 320 1 150 2 100 1 860 2 640 2 310 43 44 5 43 38 41 35 46 47 46 5 40 5 44 38 46 47 49 5 43 45 5 42 5 49 50 52 46 47 45 55 56 53 54 58 58 55 5 56 58 58 5 55 5 56 5 Starting Current A 0 43 0 62 0 86 1 05 1 53 0 93 2 53 1 55 3 02 1 84 10 5 13 3 11 0 14 0 15 5 22 0 28 5 Specifications may be subject to change without notice The GK 35 type might not be sold by the regio...

Страница 8: ...80 3 120 2 380 2 700 64 5 66 5 61 0 64 0 66 0 68 5 63 0 66 0 67 5 70 0 64 5 67 5 Starting Current A 1 4 1 3 2 1 1 9 2 8 2 6 15 5 20 25 Specifications may be subject to change without notice Specifications MK type MK 5010T E MK 5012T E Model Power Frequency Hz Three phase 50 60Hz 380 440 380V Input W Current A Air velocity Max m sec Air volume m3 h Noise dB Weight kg Width of unit cm 101 8 126 336 ...

Отзывы: