background image

Traditional

air curtain design

TWIN NOZZLE

air curtain design

Twin Nozzle air curtain takes in air from above.
(Please allow a minimum distance 100mm~150mm between the air curtain and the ceiling.)

Motor

Twin Nozzle

Protector Guard

Airflow Louvers

Punched Metal

Propeller Fans

Base Switches

Rectification Plate

Protector Guard

Motor

Twin
Nozzle

ExtraFan

ExtraFan

Front

Side

Mitsubishi Air Curtains are the Perfect  Way to Provide Your Premises with a 
Comfortable, Clean and Hygienic Environment While Saving Energy 
with a Quiet, Efficient and Powerful Operation

Patent and design registration pending for the following countries & areas:
CHINA, HONG KONG, GREAT BRITAIN, THAILAND,  MALAYSIA, SINGAPORE, TAIWAN.
Design registration pending: U.S.A., ITALY.

TWIN NOZZLE

The twin nozzle design ensures that less extraneous air 
enters the air curtain, while the outflow is wider. 
Resistance to the influence of external airflow has been 
strengthened, greatly improving insulation against heat 
and cold.

COMPACT DESIGN

EXTRAFAN

RECTIFICATION PLATE

Compact and stylish it blends in readily with your 
interior design.

By adjusting the 
installation angle of 
the main unit, the 
airflow angle can be 
altered both internally 
and externally.

ExtraFan is a major improvement over the Line Flow 
Fan. The fan is driven by an  energy efficient motor and 
costs even less to operate.

The use of Axial Fan(ExtraFan)makes it easier to 
maintain  the  unit and keep the air curtain in top 
condition  at all times. Moreover, the 
improvements  that have resulted from the change to 
the  Axial Flow Fan from the Line Flow Fan  mean that 
fan life is now even longer.

The machine can be 
installed vertically  or 
horizontally according 
to the available space.

Even Lower Energy Consumption

Easy Maintenance

Flexible Installation

Ultra-Compact Slim Design

Adjustable Airflow Angle

New innovations in high-tech 
hydromechanics have made 
Mitsubishi Electric’s ExtraFan 
run so quiet it may seem to 
lack the strength of 
conventional, noisier models.  
Not so. 
The ExtraFan not only 
reduces noise it is also the 
secret behind the GK-35’s 
powerful, high-volume airflow.

Powerful airflow without the noise

Ups speed while controlling direction

The rectification plate creates a highly directed, disc-
shaped flow by transferring airflow from the propeller 
fans without reduction to volume or velocity.  The plate 
forms the air into a smooth hemispherical wall, 
producing a high-speed current in a single direction.

Standard type

Standard type

High Power type

High Power type

COMPACT 
DESIGN

TWIN 
NOZZLE

EXTRAFAN

RECTIFICATION 
PLATE

EXTRAFAN

1

2

Содержание GK-2509YS

Страница 1: ...ecting the control switch is designed to accommodate a cabie with a diameter of 1 6mm or 2 0mm only Therefore a stranded cable cannot be connected AIR CURTAIN ON OFF Switch Operation lamp FS 04SW1 E HIGH LOW Switch LOW HIGH COMMON AIR CURTAIN LOW HIGH COMMON 1 3 4 2 1 3 0 Wiring Three phase unit Connecting the FS 04SW1 E For single phase unit A Hidden Barrier Giving Tangible Benefits A I R C U R T...

Страница 2: ...internally and externally ExtraFan is a major improvement over the Line Flow Fan The fan is driven by an energy efficient motor and costs even less to operate The use of Axial Fan ExtraFan makes it easier to maintain the unit and keep the air curtain in top condition at all times Moreover the improvements that have resulted from the change to the Axial Flow Fan from the Line Flow Fan mean that fan...

Страница 3: ... comparatively low Economic benefits of installing an air curtain Savings are calculated using an appropriate heating load factor required to keep room temperature constant at 28ºC for a room measuring 66 4m2 in area Revising the Performance Records on Shut Outs Air Curtains Increased Cold Storage Efficiency and Shut Out Effect Insect Shut Out Test HEATING MODE Economic benefits of installing an a...

Страница 4: ...um angle is indicated The above figure is posted based on the values calculated by applying the average blowout velocity In order to prevent insects from breaking into the room the air flow blown out from the air curtain must reach the attainment point at a velocity at least that indicated in the table below Choose an optimum model by consulting the figure posted on the page 11 denoting the averag...

Страница 5: ...wind 4 Install the air curtain which is the same as or slightly wider than the width of the doorway 7 To run effectively the air curtain concurrently with ventilating fan s provide ventilating or air supply opening s to avoid negative pressure to occur inside the room Otherwise run the ventilating fan of a type concurrent feeding and discharging 5 Do not leave spacing between the air curtain and t...

Страница 6: ...t A clean warehouse environment is therefore preserved Bowling Alleys Lounges The air curtain can invisibly shut out areas that do not require air conditioning For example there is no need to air condition the lane side of a bowling alley so the air curtain acts as an air conditioning zoning device The elimination of unnecessary air conditioning cuts down on costs without compromising on the provi...

Страница 7: ...0 1 760 1 950 1 350 1 400 1 330 1 320 1 150 2 100 1 860 2 640 2 310 43 44 5 43 38 41 35 46 47 46 5 40 5 44 38 46 47 49 5 43 45 5 42 5 49 50 52 46 47 45 55 56 53 54 58 58 55 5 56 58 58 5 55 5 56 5 Starting Current A 0 43 0 62 0 86 1 05 1 53 0 93 2 53 1 55 3 02 1 84 10 5 13 3 11 0 14 0 15 5 22 0 28 5 Specifications may be subject to change without notice The GK 35 type might not be sold by the regio...

Страница 8: ...80 3 120 2 380 2 700 64 5 66 5 61 0 64 0 66 0 68 5 63 0 66 0 67 5 70 0 64 5 67 5 Starting Current A 1 4 1 3 2 1 1 9 2 8 2 6 15 5 20 25 Specifications may be subject to change without notice Specifications MK type MK 5010T E MK 5012T E Model Power Frequency Hz Three phase 50 60Hz 380 440 380V Input W Current A Air velocity Max m sec Air volume m3 h Noise dB Weight kg Width of unit cm 101 8 126 336 ...