Output to device
:
Add auxiliary relays according to the device outputs.
RY1 Conveyor leftward
relay output
Y
1
Y2
M2
1
RY1 leftward operation command
M2
2
RY2 rightward operation command
RY2 Conveyor rightward
relay output
M110
Conveyor leftward operation
M
1
20
Conveyor rightward operation
RY1
RY2
Ladder example
1
The following program
runs
automatic operations.
•
After X0 is turned on
, the system operates in
the low-speed mode for 3sec.
Then the system operates in
the high-speed mode for 10sec. and stops.
Low speed
High speed
3sec.
10sec.
X0
T1
M110
M110
OUT
T1
K30
M110
PLF
M112
M112
T2
M120
M120
OUT
T2
K100
M110
Y1
M120
Y2
Instruction for auto low-speed
Instruction for auto high-speed
Low-speed operation
High-speed operation