1.3
System Configuration
1.3.1
General configuration
1.3.2
Applicable PLC
The version number can be checked by reading the last three digits of device D8001/D8101.
*1.
An FX
2NC
-CNV-IF or FX
3UC
-1PS-5V is necessary to connect the FX
3U
-J1939 to an FX
3GC
/FX
3UC
PLC.
*2.
Check the current consumption of the connected extension blocks and insert extension power supply
units if necessary.
*3.
Up to 7 units can be connected to the FX
3UC
-32MT-LT(-2) PLC.
*4.
An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect the FX
3U
-J1939 to an FX5U/FX5UC
PLC.
*5.
Applicable for FX
3U
-J1939 firmware Ver. 1.11 and later.
Part Name
Model Name
Remarks
Communication block
FX
3U
-J1939
PLC
FX
3G
/FX
3GC
/FX
3U
/
FX
3UC
/FX5U/FX5UC
PLC
An FX
2NC
-CNV-IF or FX
3UC
-1PS-5V is necessary to connect the FX
3U
-
J1939 to an FX
3GC
/FX
3UC
Series PLC.
An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect the FX
3U
-
J1939 to an FX5U/FX5UC PLC.
CAN bus network
-
CAN bus network
Node
-
J1939 Node or CAN Layer 2 Node
Terminating resistor
-
The CAN bus network requires terminating resistors for both network ends.
Maximum transmission
distance
-
•
SAE J1939-11: 40 m (131'2"), stubs max. 1 m (3'3") at 250 kbps
•
SAE J1939-15: 40 m (131'2"), stubs max. 3 m (9'10") at 250 kbps
•
CAN (Layer 2): 5000 m (16,404'2") at 10 kbps (with repeaters).
The transmission distance is reduced to 25 m (82') at
the maximum baud rate of 1 Mbps.
The maximum distance also depends on the specification of other
connected nodes.
Model name
Applicability
FX
3G
Series PLC
Ver. 1.00 and later (Up to 8 blocks can be extended
*2
)
FX
3GC
Series PLC
*1
Ver. 1.40 and later (Up to 8 blocks can be extended
*2
)
FX
3U
Series PLC
Ver. 2.20 and later (Up to 8 blocks can be extended
*2
)
FX
3UC
Series PLC
*1
Ver. 2.20 and later (Up to 8 blocks can be extended
*2*3
)
FX5U PLC
*4*5
Ver. 1.031 and later (Up to 8 blocks can be extended)
FX5UC PLC
*4*5
Ver. 1.031 and later (Up to 4 blocks can be extended)
Node 1
FX
3G
/FX
3GC
/
FX
3U
/FX
3UC
/
FX5U/FX5UC PLC
FX
3U
-J1939
Communication
block
Node 2
Node 3
Node 4
Node 5
Terminating
resistor
Terminating
resistor
Node 6
CAN bus network