3 - 21
MELSEC-F
SPECIFICATIONS
3
3 - 21
(h) Mail send parameter settings (BFM #9856 to 14499)
(Continues on the next page)
BFM number
Attribute
Application
Name
Initial value
Decimal
(Hexadecimal)
Flash ROM
save
Reference
section
Decimal
(Hexadecimal)
9856 to 9887
(2680 to 269F
H
)
R/W
Shared area for
e-mail buffers
Local station mail address (Maximum of 64 characters)
"\0"
Chapter 10
9888 to 9903
(26A0 to 26AF
H
)
—
System area
—
—
Chapter 10
9904
(26B0
H
)
R/W
Flag indication whether checks (b15) are received
OFF: No check ON: Check
Check unit designation (b14 to b12)
0: Hour, 1: Minute, 2: Second
Check interval (b11 to b0)
For hour
: 1 to 24
For minute : 1 to 1440
For second : 30 to 3600
1005
H
(5 minutes)
Chapter 10
9905 to 9912
(26B1 to 26B8
H
)
—
System area
—
—
Chapter 10
9913 to 9920
(26B9 to 26C0
H
)
R/W
Password to the POP3 server (16 characters)
"\0"
Chapter 10
9921
(26C1
H
)
R/W
Method for designating SMTP server
0: Domain name designation
1: IP address designation (Decimal)
2: IP address designation (Hexadecimal)
1
Chapter 10
9922 to 9953
(26C2 to 26E1
H
)
R/W
Domain name of the SMTP server (maximum 64 characters)
or IP address
*1
0.0.0.0
Chapter 10
9954
(26E2
H
)
R/W
Method for designating POP3 server
0: Domain name designation
1: IP address designation (Decimal)
2: IP address designation (Hexadecimal)
1
Chapter 10
9955 to 9986
(26E3 to 2702
H
)
R/W
Domain name of the POP3 server (maximum 64 characters)
or IP address
*1
0.0.0.0
Chapter 10
9987 to10018
(2703 to 2722
H
)
R/W
Send destination address 1
"\0"
Chapter 10
10019 to 10050
(2723 to 2742
H
)
R/W
Send destination address 2
"\0"
Chapter 10
10051 to 10082
(2743 to 2762
H
)
R/W
Send destination address 3
"\0"
Chapter 10
10083 to 10114
(2763 to 2782
H
)
R/W
Send destination address 4
"\0"
Chapter 10
10115 to 10146
(2783 to 27A2
H
)
R/W
Send destination address 5
"\0"
Chapter 10
10147 to 10178
(27A3 to 27C2
H
)
R/W
Send destination address 6
"\0"
Chapter 10
10179 to 10210
(27C3 to 27E2
H
)
R/W
Send destination address 7
"\0"
Chapter 10
10211 to 10242
(27E3 to 2802
H
)
R/W
Send destination address 8
"\0"
Chapter 10
10243 to 10274
(2803 to 2822
H
)
R/W
Send destination address 9
"\0"
Chapter 10
10275 to 10306
(2823 to 2842
H
)
R/W
Send destination address 10
"\0"
Chapter 10
10307 to 10332
(2843 to 285C
H
)
—
System area
—
—
Chapter 10