Buffer Memory (BFM) 8
8-15
8.2.2
BFM #2 to BFM #9: Number of times of averaging
When using BFM #10 to #17 as the average data, write the number of times of averaging to
BFM #2 to BFM #9.
The setting range of the number of times of averaging is 1 to 4,095.
However, when you set the number of times of averaging to "1", the immediate data (current
value) is stored in BFM #10 to BFM #17.
When you set the number of times of averaging to "0" or a smaller value, "0" is written. When
you set the number of times of averaging to "4,096" or a larger value, "4,096" is written. In
either case, a number of times of averaging setting error (BFM #29 b10) occurs.
The initial value is "1".