3. CONVERSION RULES FOR THE PROGRAM CONVERSION FUNCTION
-
-
Yes
K55
Addition between D and K with carry
addition (3-digit BCD)
ADD (FNC 20)
-
-
Yes
K56
Addition between D and K with carry
addition (6-digit BCD)
ADD (FNC 20)
-
-
Yes
K57
Addition between data registers
(3-digit BCD)
ADD (FNC 20)
-
-
Yes
K58
Addition between data registers with
carry addition (3-digit BCD)
ADD (FNC 20)
-
-
Yes
K59
Addition between data registers with
carry addition (6-digit BCD)
ADD (FNC 20)
-
-
Yes
K60
Addition between data registers
(3-digit OCT)
ADD (FNC 20)
-
-
Yes
K61
Data register increment
(3-digit BCD)
INC (FNC 24)
-
-
Yes
K62
Data register increment
(6-digit BCD)
INC (FNC 24)
-
-
Yes
K63
Data register increment
(3-digit OCT)
INC (FNC 24)
The corresponding FX series instruction is
a binary operation, so the numerical control
for the relevant program needs to be
changed from octal to binary (decimal).
-
-
Yes
K64
Current counter value increment
(3-digit BCD)
INC (FNC 24)
-
-
Yes
K65
Current counter value increment
(6-digit BCD)
INC (FNC 24)
-
-
Yes
K66
Subtraction between D and K with
borrow subtraction (3-digit BCD)
SUB (FNC 21)
-
-
Yes
K67
Subtraction between D and K with
borrow subtraction (6-digit BCD)
SUB (FNC 21)
-
-
Yes
K68
Subtraction between data registers
(3-digit BCD)
SUB (FNC 21)
-
-
Yes
K69
Subtraction between data registers
with borrow subtraction
(3-digit BCD)
SUB (FNC 21)
-
-
Yes
K70
Subtraction between data registers
with borrow subtraction
(6-digit BCD)
SUB (FNC 21)
-
-
Yes
K71
Subtraction between data registers
(3-digit OCT)
SUB (FNC 21)
-
-
Yes
K72
Data register decrement
(3-digit BCD)
DEC (FNC 25)
-
-
Yes
K73
Data register decrement
(6-digit BCD)
DEC (FNC 25)
-
-
Yes
K74
Data register decrement
(3-digit OCT)
DEC (FNC 25)
The corresponding FX series instruction is
a binary operation, so the numerical control
for the relevant program needs to be
changed from octal to binary (decimal).
-
-
Yes
K75
Current counter value decrement
(3-digit BCD)
DEC (FNC 25)
*1 Generic term for F
2
series running on versions
earlier than V2.1
*2 Generic term for F
2
series running on version
V2.1 or later
Application instructions for F
1
, F
1J
, and F
2
programmable controllers
Application instruction (FNC number) and
function of the FX programmable controller
to be changed
Applicable model
Instruction
number
F670
Name
F
1
, F
1J
F
2*1
New F
2*2