3. CONVERSION RULES FOR THE PROGRAM CONVERSION FUNCTION
25
1
OVER
VIEW
OF T
RAN
SITIO
N
FR
OM
F S
ERIE
S (F1
, F1
J,
AND
F2
) TO
FX
3 SE
RIES
2
OV
ER
VIE
W
OF
P
RO-
GR
AM
CO
NV
ER
SIO
N
US
ING
FX
-20
P-E
3
CONVE
RSION RU
LES
FOR
THE
PRO
GR
AM
CONVE
RSION F
UNCT
ION
A1
D
isc
on
tinu
ed
M
ode
ls [
Pro
gr
am
-
m
abl
e C
ont
roll
er
]
A2
R
el
ev
ant
M
anuals
A3
F
requent
ly
A
sked Q
u
es-
tio
n
s
3.2.2
Auxiliary relay (M) [Excluding special auxiliary relay (M)]
The relay for general use and the relay for backup power are converted as shown in the table below.
3.2.3
Timer (T)
The timer is converted according to the minimum value as shown in the table below.
In F
1
, F
1J
, and F
2
, timers can be entered up to three digits, including decimals. Using the 0.1-sec timer as an example, if the
minimum value of the T50 timer is set to 0.1 sec, the T0 timer will be set to 1 after converting to FX, according to the table
above. Integer values are entered for FX, but K1 is equal to 0.1 sec in the FX series, so the same timer value of 0.1 sec is set.
F
1
, F
1J
, F
2
FX
For general use
(without
backup)
M100 to M107
Convert
M0 to M7
M110 to M117
M8 to M15
M120 to M127
M16 to M23
M130 to M137
M24 to M31
M140 to M147
M32 to M39
M150 to M157
M40 to M47
M160 to M167
M48 to M55
M170 to M177
M56 to M63
M200 to M207
M64 to M71
M210 to M217
M72 to M79
M220 to M227
M80 to M87
M230 to M237
M88 to M95
M240 to M247
M96 to M103
M250 to M257
M104 to M111
M260 to M267
M112 to M119
M270 to M277
M120 to M127
For backup
power
(with backup)
M300 to M307
M500 to M507
M310 to M317
M508 to M515
M320 to M327
M516 to M523
M330 to M337
M524 to M531
M340 to M347
M532 to M539
M350 to M357
M540 to M547
M360 to M367
M548 to M555
M370 to M377
M556 to M563
F
1
, F
1J
, F
2
FX
Minimum timer value Element number
Setting value
Minimum timer value Element number
Setting value
0.1-sec timer
(0.1 to 999 sec)
K0.1 = 0.1 sec
(100-msec timer)
T50 to T57
K99.9 to 0.1
Convert
100-msec timer
(0.1 to 3276.7 sec)
K1 = 0.1 sec
T0 to T7
K999 to 1
K999 to 1
K9990 to 10
T450 to
T457
K99.9 to 0.1
T8 to T15
K999 to 1
K999 to 1
K9990 to 10
T550 to
T557
K99.9 to 0.1
T16 to T23
K999 to 1
K999 to 1
K9990 to 10
0.01-sec timer
(0.01 to 99.9 sec)
K0.01 = 0.01 sec
(10-msec timer)
T650 to
T657
K99.9 to 0.01
(999 to 1)
10-msec timer
(0.01 to 327.67 sec)
K1 = 0.01 sec
T200 to
T207
K999 to 1
K99.9 to 0.1
K9990 to 10