
3. CONVERSION RULES FOR THE PROGRAM CONVERSION FUNCTION
35
1
OVER
VIEW
OF T
RAN
SITIO
N
FR
OM
F S
ERIE
S (F1
, F1
J,
AND
F2
) TO
FX
3 SE
RIES
2
OV
ER
VIE
W
OF
P
RO-
GR
AM
CO
NV
ER
SIO
N
US
ING
FX
-20
P-E
3
CONVE
RSION RU
LES
FOR
THE
PRO
GR
AM
CONVE
RSION F
UNCT
ION
A1
D
isc
on
tinu
ed
M
ode
ls [
Pro
gr
am
-
m
abl
e C
ont
roll
er
]
A2
R
el
ev
ant
M
anuals
A3
F
requent
ly
A
sked Q
u
es-
tio
n
s
-
Yes
Yes
K26
Y, M, and S batch reset
ZRST (FNC 40)
-
Yes
Yes
K27
Write 1- to 3-digit decimal constants MOV (FNC 12)
-
Yes
Yes
K28
Write 3-digit octal constants
MOV (FNC 12)
-
-
Yes
K29
N-bit information transfer
MOV (FNC 12)
-
Yes
Yes
K30
Write decimal constants for T and C
(set value register)
MOV (FNC 12)
-
Yes
Yes
K31
Write T and C set value register
MOV (FNC 12)
-
Yes
Yes
K32
Read T and C set value register
MOV (FNC 12)
-
Yes
Yes
K33
Write decimal constants for T, C
(current value register), and D
MOV (FNC 12)
-
Yes
Yes
K34
Read T, C (current value register),
and D
MOV (FNC 12)
-
Yes
Yes
K35
Read T, C, and D current values
MOV (FNC 12)
-
-
Yes
K36
Write to data register
MOV (FNC 12)
-
-
Yes
K37
Read data register
MOV (FNC 12)
-
-
Yes
K38
Write same decimal constants
MOV (FNC 12)
BMOV (FNC 15)
-
-
Yes
K39
Transfer same data
MOV (FNC 12)
FMOV (FNC 16)
-
Yes
Yes
K40
Comparison of constants with T, C,
and D current values
CMP (FNC 10)
-
Yes
Yes
K41
Comparison of BCD input with T, C,
and D current values
CMP (FNC 10)
-
-
Yes
K42
Comparison of BCD input with C
and D current values
CMP (FNC 10)
-
Yes
Yes
K43
Band comparison of T, C, and D cur-
rent values
ZCP (FNC 11)
-
Yes
Yes
K44
6-digit band comparison of C and D
current values
ZCP (FNC 11)
-
-
Yes
K45
Comparison of current counter value
between data registers
CMP (FNC 10)
-
-
Yes
K46
Data register clear check
CMP (FNC 10)
-
-
Yes
K47
Data register complement
(3-digit BCD)
NEG (FNC 29)
-
-
Yes
K48
Clear data register specification digit SMOV (FNC 13)
-
-
Yes
K49
Data interchange
XCH (FNC 17)
-
-
Yes
K50
Transfer between set value register
and data register
MOV (FNC 12)
-
-
Yes
K51
Transfer between current value reg-
ister and data register
MOV (FNC 12)
-
-
Yes
K52
Transfer via (D) to D indirect specifi-
cation
MOV (FNC 12)
Indirect specification through index modifi-
cation (use of both index registers V and Z)
-
-
Yes
K53
Transfer via D to (D) indirect specifi-
cation
-
-
Yes
K54
Transfer via (D) to (D) indirect speci-
fication
*1 Generic term for F
2
series running on versions
earlier than V2.1
*2 Generic term for F
2
series running on version
V2.1 or later
Application instructions for F
1
, F
1J
, and F
2
programmable controllers
Application instruction (FNC number) and
function of the FX programmable controller
to be changed
Applicable model
Instruction
number
F670
Name
F
1
, F
1J
F
2*1
New F
2*2
Содержание FX Series
Страница 2: ......
Страница 44: ...42 Appendix 1 Discontinued Models Programmable Controller MEMO ...
Страница 53: ......