24
FUNCTION AND BASIC OPERATION
2.3 Direct setting
When setting
Pr.1000 Direct setting selection
, it is possible to switch from the Main monitor screen to the set point setting
screen for PID action using
. On each setting screen, turn
to input a setting value, and press
to confirm the
setting.
This setting is available only when the inverter supports this function. (Refer to
.)
When
Pr.1000
="0"
When
Pr.1000
="1"
When
Pr.1000
="2"
Not displayed when PID control is disabled (
Pr.128
="0").
Indication of [NEXT] is not displayed when
Pr.1000
="0".
To switch back the monitor display from the Direct screen or the Frequency setting screen to the Main monitor screen, press
.
Pr.1000 setting
Description
0 (Initial value)
Displays the Frequency setting screen.
1
Displays the Direct (set point setting) screen.
2
Displays the Direct (set point setting) screen and the Frequency setting screen.
(SET)
One of the Main monitor screen
Example of screen switching and shifting when the PID control is enabled (
Pr.128
≠
"0")
Direct #1 screen
∗5
Direct #2 screen
∗5
Frequency setting screen
∗6
(NEXT)
(NEXT)
(NEXT)
∗4
(NEXT)
∗3
∗2
∗3,∗4
∗3,∗4
∗4
PREV
SET
NEXT
STOP
PU
Hz
Output frequency
1 2 : 3 4
0.00
N E X T
BACK
SET
NEXT
STOP
PU
Frequency Setting
Pres value
Set value
0.00Hz
100.00Hz
10.0PSI
10.0PSI
N E X T
BACK
SET
NEXT
STOP
PU
PID act set pnt
Pres value
Set value
10.0PSI
10.0PSI
N E X T
BACK
SET
NEXT
STOP
PU
2ndPID set point
Pres value
Set value
(BACK)