8. (E) Environment Setting Parameters
8.9 Multiple rating setting
1
2
3
4
5
6
7
8
9
10
8.9
Multiple rating setting
Two rating types of different rated current and permissible load can be selected. The optimal inverter rating can be selected
according to the application, enabling equipment to be downsized.
*1
Available for the three-phase power input model only.
Changing the parameter initial values and setting ranges
• When inverter reset and all parameter clear are performed after setting
Pr.570
, the parameter initial values are changed
according to each rating, as shown below.
*1
Initial values differ depending on the rating as follows.
*2
The rated current and motor capacity values differ depending on the inverter capacity. Refer to the inverter rated specifications in the Instruction
Manual (Connection).
Pr.
Name
Initial value
Setting
range
Description (overload current rating, surrounding air temperature)
570
E301
Multiple rating setting
2
1
LD rating.
120% for 60 seconds, 150% for 3 seconds (inverse-time characteristics)
at surrounding air temperature of 50°C.
2
ND rating.
150% for 60 seconds, 200% for 3 seconds (inverse-time characteristics)
at surrounding air temperature of 50°C.
Pr.
Name
Pr.570 setting
Refer to
page
1
2 (initial value)
0
Torque boost
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
LD rated current
ND rated current
12
DC injection brake operation voltage
22
Stall prevention operation level
120%
150%
44
Second acceleration/deceleration time
48
Second stall prevention operation level
120%
150%
56
Current monitoring reference
LD rated current
ND rated current
150
Output current detection level
120%
150%
165
Stall prevention operation level for restart
120%
150%
557
Current average value monitor signal output
reference current
LD rated current
ND rated current
874
OLT level setting
120%
150%
893
Energy saving monitor reference (motor capacity) LD rated motor capacity
ND rated motor capacity
FR-E820-[]
FR-E840-[]
FR-E820S-
[]
Pr.0 (%)
Pr.7, Pr.8, Pr.44 (s)
Pr.12 (%)
ND
LD
ND
LD
ND
LD
0008 (0.1)
—
0008 (0.1)
6
6
5
5
6
6
0015 (0.2)
—
0015 (0.2)
6
6
5
5
6
4
0030 (0.4)
0016 (0.4)
0030 (0.4)
6
6
5
5
4
4
0050 (0.75)
0026 (0.75)
0050 (0.75)
6
4
5
5
4
4
0080 (1.5)
0040 (1.5)
0080 (1.5)
4
4
5
5
4
4
0110 (2.2)
0060 (2.2)
0110 (2.2)
4
4
5
5
4
4
0175 (3.7)
0095 (3.7)
—
4
3
5
10
4
4
0240 (5.5)
0120 (5.5)
—
3
3
10
10
4
4
0330 (7.5)
0170 (7.5)
—
3
2
10
15
4
2
FR-E860-[]
Pr.0 (%)
Pr.7, Pr.8, Pr.44 (s)
Pr.12 (%)
ND
LD
ND
LD
ND
LD
0017 (0.75) 5
3
5
5
1
1
0027 (1.5)
3
3
5
5
1
1
0040 (2.2)
3
2
5
5
1
1
0061 (3.7)
2
2
5
10
1
1
0090 (5.5)
2
2
10
10
1
1
0120 (7.5)
2
1
10
15
1
1
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...