102
4. Control Method
4.3 Selecting the Advanced magnetic flux vector control
4.3
Selecting the Advanced magnetic flux vector
control
• To use the Advanced magnetic flux vector control, select the control method using
Pr.800
, and the motor type and specification
using
Pr.71, Pr.80, and Pr.81
.
Advanced magnetic flux vector control
Operating procedure
1.
Perform wiring properly. (Refer to the Instruction Manual (Connection).)
2.
Change the control method to Advanced magnetic flux vector control (
Pr.800
= "20").
3.
Make the motor setting (
Pr.71
).
• 200/400 V class
• 575 V class
*1
For the other setting values of
Pr.71
, refer to
.
*2
For offline auto tuning, refer to
4.
Set the motor overheat protection (
Pr.9
5.
Set the motor capacity and number of motor poles (
Pr.80, Pr.81
.)
Operation does not start when the setting value is "9999" (initial value).
6.
Set the rated motor voltage and frequency (
Pr.83, Pr.84
). (Refer to
.)
7.
Set the operation command. (Refer to
.)
Select the start command and speed command.
8.
Perform the test operation.
As required
Magnetic flux
Magnetic flux
Magnetic flux
Motor
Pr.71 setting
Remarks
Mitsubishi Electric standard efficiency motor
Mitsubishi Electric high-efficiency motor
SF-JR
0 (initial value) (3)
SF-JR 4P 1.5 kW or lower
20
SF-HR
40
Others
0 (3)
Offline auto tuning is required.
Mitsubishi Electric constant-torque motor
SF-JRCA 4P
10
SF-HRCA
50
Other (SF-JRC, etc.)
10 (13)
Offline auto tuning is required.
Mitsubishi Electric high-performance energy-
saving motor
SF-PR
70 (73)
Mitsubishi Electric geared motor (constant-
torque)
GM-[]
1800 (1803)
Other manufacturer's standard motor
—
0 (3)
Offline auto tuning is required.
Other manufacturer's constant-torque motor
—
10 (13)
Offline auto tuning is required.
Motor
Pr.71 setting
Remarks
Standard motor
0 (initial value) (3)
Constant-torque motor
10
Offline auto tuning is required.
Other manufacturer's standard
motor
0 (3)
Offline auto tuning is required.
Other manufacturer's
constant-torque motor
10 (13)
Offline auto tuning is required.
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...