3.2 Function differences from the FR-A8AP
• The following tables show the function differences from the FR-A8AP (option compatible with encoder).
• Both the FR-A8APR and the FR-A8AP cannot be used together. If the FR-A8APR and the FR-A8AP are installed together in
the inverter, the FR-A8AP is disabled.
Parameter for detector
Control method
: Supported,
―
: Not supported
Major functions list
Item
FR-A8APR parameter
FR-A8AP parameter
Resolver/Encoder rotation direction
Pr.359
Number of detector pulses
―
(fixed 1024 pulses)
Pr.369
Encoder signal loss detection enable/disable selection
Pr.376
Control method
Motor
FR-A8APR
FR-A8AP
V/F control (orientation control, encoder feedback control)
Induction motor
Advanced magnetic flux vector control (orientation control,
encoder feedback control)
Induction motor
Vector control
Induction motor
PM motor
―
Function
FR-A8APR
FR-A8AP
Induction motor
PM motor
Induction motor
Vector control (speed control)
Vector control (torque control)
―
Vector control (position control)
Orientation control
Encoder feedback control
―
Содержание FR-A8APR