![Mitsubishi Electric FR-A8APR Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/mitsubishi-electric/fr-a8apr/fr-a8apr_instruction-manual_239773014.webp)
14
• Extension of the signal cable
Use shielded twisted pair cables to extend the signal cable from the resolver. For connection with the signal cables, solder
them or fix them with screws on the terminal block. Insulate and disconnect the shielded cable of the resolver.
NOTE
• The wiring length should be 100 m at the maximum.
R1
R
2
S2
S4
S1
S3
C
M
A8APR circuit board
Terminals
R1
R2
S2
S4
S1
S3
CM
R2: Yellow/White
S2: Yellow
S4: Blue
S3: Black
Resolver
Loose
wires
Shielded twisted pair cable
Example of TS2640N321E64 manufactured by Tamagawa Seiki Co., Ltd.
For the extension of the signal cable used for the resolver above, the following wire is recommended.
V-3PB-02S manufactured by Totoku Electric Co., Ltd.
Connect by soldering or using
the terminal block.
Shielded cable
R1: Red/White
S1: Red
∗1
∗1
Содержание FR-A8APR