35
DRIVE THE MOTOR
89
Speed control gain
(Advanced magnetic
flux vector)
0 to 200%, 9999
9999
90
Motor constant (R1)
0 to 50
Ω
,
9999
*2
9999
0 to 400m
Ω
,
9999
*3
91
Motor constant (R2)
to 50
Ω
,
9999
*2
9999
0 to 400m
Ω
,
9999
*3
92
Motor constant (L1)/
d-shaft inductance
(Ld)
0 to 6000mH,
9999
*2
9999
0 to 400mH,
9999
*3
93
Motor constant (L2)/
q-shaft inductance
(Lq)
0 to 6000mH,
9999
*2
9999
0 to 400mH,
9999
*3
94
Motor constant (X)
0 to 100%, 9999
9999
95
Online auto tuning
selection
0 to 2
0
96
Auto tuning setting/
status
0, 1, 11, 101
0
100
V/F1 (first frequency)
0 to 590Hz,
9999
9999
101
V/F1 (first frequency
voltage)
0 to 1000V
0V
102
V/F2
(second frequency)
0 to 590Hz,
9999
9999
103
V/F2 (second
frequency voltage)
0 to 1000V
0V
104
V/F3
(third frequency)
0 to 590Hz,
9999
9999
105
V/F3 (third frequency
voltage)
0 to 1000V
0V
106
V/F4
(fourth frequency)
0 to 590Hz,
9999
9999
107
V/F4 (fourth
frequency voltage)
0 to 1000V
0V
108
V/F5 (fifth frequency)
0 to 590Hz,
9999
9999
109
V/F5 (fifth frequency
voltage)
0 to 1000V
0V
110
Third acceleration/
deceleration time
0 to 3600s,
9999
9999
111
Third deceleration
time
0 to 3600s,
9999
9999
112
Third torque boost
0 to 30%, 9999
9999
113
Third V/F
(base frequency)
0 to 590Hz,
9999
9999
114
Third stall prevention
operation level
0 to 400%
150%
115
Third stall prevention
operation frequency
0 to 590Hz
0Hz
116
Third output
frequency detection
0 to 590Hz
60/50Hz
*10
117
PU communication
station number
0 to 31
0
Parameter Name
Setting Range
Initial
Value
118
PU communication
speed
48, 96, 192,
384, 576, 768,
1152
192
119
PU communication
stop bit length /
data length
0, 1, 10, 11
1
120
PU communication
parity check
0 to 2
2
121
Number of PU
communication
retries
0 to 10, 9999
1
122
PU communication
check time interval
0, 0.1 to 999.8s,
9999
9999
123
PU communication
waiting time setting
0 to 150ms,
9999
9999
124
PU communication
CR/LF selection
0 to 2
1
125
Terminal 2 frequency
setting gain
frequency
0 to 590Hz
60/50Hz
*10
126
Terminal 4 frequency
setting gain
frequency
0 to 590Hz
60/50Hz
*10
127
PID control
automatic
switchover
frequency
0 to 590Hz,
9999
9999
128
PID action selection
0, 10, 11, 20, 21,
40 to 43, 50, 51,
60, 61, 70, 71,
80, 81, 90, 91,
100, 101, 1000,
1001, 1010,
1011, 2000,
2001, 2010,
2011
0
129
PID proportional
band
0.1 to 1000%,
9999
100%
130
PID integral time
0.1 to 3600s,
9999
1s
131
PID upper limit
0 to 100%,
9999
9999
132
PID lower limit
0 to 100%,
9999
9999
133
PID action set point
0 to 100%,
9999
9999
134
PID differential time
0.01 to 10.00s,
9999
9999
135
Electronic bypass
sequence selection
0, 1
0
136
MC switchover
interlock time
0 to 100s
1s
137
Start waiting time
0 to 100s
0.5s
138
Bypass selection at a
fault
0, 1
0
139
Automatic switch-
over frequency
between inverter and
commercial power-
supply operation
0 to 60Hz,
9999
9999
140
Backlash
acceleration
stopping frequency
0 to 590Hz
1Hz
Parameter Name
Setting Range
Initial
Value
Simple
Simple
Simple
Simple
Simple
Simple
*2
For FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower
*3
For FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher
*10
Differs according to types. (FM type/CA type)
Содержание FR-A800
Страница 67: ......